                        Downfl ow, Upfl ow Electric Furnaces
Owners Manual/Installation Instructions
E3 Series (Air Conditioner/Heat Pump Air Handler)
IMPORTANT:  Read this owner information 
to become familiar with the capabilities and 
use of your heating appliance.  Keep this 
literature where you will have easy access 
to it in the future.  If a problem occurs, check 
the instructions and follow recommenda-
tions given. If these suggestions don’t 
eliminate your problem, call the appropriate 
NORDYNE distributor.  A 
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        2                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Temperature Selector 10        20        30 Temperature  Scales 50 60 70 80 90 Fan Switch (optional sub-base) System Switch Indoor Coil SYSTEM VENTILATE (optional sub-base) HEAT  OFF  COOL ON   AUTO (optional) Coil Air Filters (used with indoor coil) Furnace Air Filter (NOT used with  coil air filters) Blower Circuit Breakers Data Label Control Panel Cover (left) Control Panel Cover (right) Figure 1. Furnace Parts Identifi cation E 3 EB - 010 H Product Type Electrical Code E - Electric Furnace H 
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        To Operate System in Cooling Mode To Shut Off System 1. Make sure blower selector switch is on  NOTE:  The “FAN ON/FAN AUTO” (fan switch)  “Auto”. and “HEAT/OFF/COOL” (system switch) are  2. Set thermostat temperature selector to  located either on your thermostat (if it’s supplied  lowest temperature setting, OR... with a sub-base) or on the relay box added to  3. For thermostats with optional sub-base (see  your furnace. Figure 1), or for systems with relay box, set  system switch to “OFF.” 1.
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        SECTION 2. BEFORE YOU CALL A SERVICEMAN 1. Make sure thermostat temperature selector  INSTALLER INFORMATION is set above room temperature for heating  GENERAL or below room temperature for cooling.  If  These instructions and specifi cations are pri- thermostat is equipped with heating/cool- marily intended to assist qualifi ed individuals  ing sub-base, make sure system switch  experienced in the proper installation of home  (see Figure 1) is set to “HEAT” for furnace  heating and air conditionin
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Power entrance for all models may be through the � American National Standards (ANSI) A119.11,  right side or through the bottom of the unit (when C1-NFPA 7 (National Electrical Code)  viewing the unit in a downfl ow position). � CANADIAN STANDARDS (C.S.A.) Z240.6.1,  and Z240.9.1.  UNIT CHECKOUT All local codes having jurisdiction shall also  Before installing this furnace: apply. 1. Inspect unit for possible shipping damage.   If shipping damage is found, fi le claim with  Air Duct Codes and Spe
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Return Air Codes and Requirements Return Air Grille   A return air grille and frame assembly (see Figure  Unducted return air systems may be used for  2) is available for use in unducted return air instal- closet or alcove installations.  lations. In downfl ow alcove installations, the grille  and frame assembly may be mounted directly  NOTE: Applicable installation codes may limit the  to the top of the furnace. In closet installations,  furnace to installation in a single-story residence  a wal
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        20" (508 mm) 23 3/4" (603 mm) 8 Item Number Description (See Figure) 7 4-Speed Blower 1 4 Ton - See notes: 1 & 5 5 Ton - See Note: 1 4 27" A.C./H.P. Relay Control (686 mm) 2 See Note: 1 Cabinet insulation Kit 3 See Notes: 1 & 5 A-Coil Conversion Kit 4 See Note: 2 1 Coil Cabinet 5 2 See Note: 3 29" Upfl ow Stand 6 (737 mm) See Note: 4 3 7 A/C and H/P Indoor Coils Return Air Grille and  8 Frame Notes:  1) For A/C and H/P use.  2) Includes coil fi lters.  3) For upfl ow or downfl ow installations.  4) 
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        Table 3.  Unit Specifi cations E3EH Electric Furnace Models 010H 012H 015H 017H 020H 023H Rated Heating Output, Btuh                   35,000 41,000 53,000 57,000 70,000 75,000 (see note 1) Watts (Total kw, Heating  10.4 12.0 15.4 16.6 20.4 22.0 Elements and Blower) Supply Voltage 240 Volts/60Hz/1-Phase Heating Elements,                       2 (10.0) 2 (11.6) 3 (15.0) 3 (16.2) 4 (20.0) 4 (21.6) No.(Total kw) Blower Wheel Size 10.5" Dia., 8" Wide Motor Speed,                          2 Speed, 1/5
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        (see Figure 3) supplied with the duct connec- NOTE: Refer to the instructions supplied with  tors is recommended for use with this type of  any additional accessories for further installa- installation. tion details. Filtering Methods - Non-Ducted Return Air Selecting Duct Connector 1. Without A/C or H/P uncased coil: Non Platinum Duct Connector  - use the fi lter supplied with the furnace;  1. Determine depth of fl oor cavity from surface  ensure that the fi lter is installed mat side  of fl oor to
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Preparing Floor Opening(s) If "X" Use Duct Connector 1. Mark fl oor opening(s) as shown in Figure  fl oor cavity is: Model Part Number 6. Provide minimum clearances at rear  Metric Finger Screw  and right side walls of closet or alcove for  English (mm) Tab Down installation of furnace and wiring. 7/8" 22 901987 904008 2. Cut fl oor opening on outside edge of marked  2" 51 901988 904009 line so that opening is slightly larger than  4 1/4" 108 901989 904010 area marked. 6 1/4" 159 901990 904011 3. A
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Rear Wall Mounting  Plate Floor  Opening Optional Supply       Entrance Cut-out Area Refrigerant  Line  Opening Supply Air Duct Cut Duct Opening 1/16th. Larger Than  Plenum Connector Figure 7.  Rear Mounting Plate Secure Duct Connector & Mtg Plate With 2 Flat Head Screws  or Nails At Dimpled Locations  Mounting  Rear Wall Plate Plenum Bend Connector Tabs Under Duct Opening Refrigerant  Line  Opening Supply Air Duct Figure 8.  Duct Connector (Non Platinum) Method B 4. Secure duct connector to fl o
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Secure Duct Connector and Mounting  Plate with 2 Flat-Head Screws or Nails Mounting Plate Duct Connector 14" Supply Connection Figure 9.  Platinum Duct Connector Method D 5. Fold/form the duct fl ap against the side of  1. Score and cut top of metal duct as indicated the duct connector and attach as shown  in Figure 12, Step 1 or Step 2.  If using Step (see Figure 12, Step 4). Use at least three  1, also cut out metal from the shaded area staples on each duct fl ap OR... if a 2X  “A”. block/joist 
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        2.   Locate the duct connector over duct and  Alcove Installation carefully lower screw down duct connector  1. Cut alcove rough openings to minimum  into place. dimensions shown in Figure 13. 3. Once duct connector is located on duct,  2. Attach frame assembly with four fasteners  temporarily hold in place while fastening  (provided or equivalent) into pre-punched  duct connector to the fl oor using fl at head  holes on top of furnace (see Figure 5). screws or nails. Be sure fl anges of duct  3. A
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        6" (152 mm) 1" (25 mm) Holes (4) Wall  Return Panel Air Grille Coil Air  Filters 27" (686 mm) 56" (1423 mm) A/C or H/P Coil 29" Wall-Mount ( 737 mm) 24 3/4" Return Air Grille (629 mm) Furnace Front Closet 18" Door Nearest 20" Wall or (508 mm) Floor Partition Figure 13.  Typical Alcove Installation Figure 14.  Typical Closet Installation 2. Remove refrigerant line knockouts in fur- Provide min. 235 nace only when installing indoor coil of an sq. in. (1516 cm  ) open free area in air conditioner o
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Power Supply Refrigerant Wire Line Entrances Knockouts Power Supply Blower Selector Wire Switch (EH Only) Refrigerant Entrances Line Knockouts Tie Down Tab Blower Selector Tie-Down Tab Switch (EH Only) Low Voltage (See Inset) Wire Entrances DOWNFLOW INSTALLATION UPFLOW INSTALLATION Figure 16. Downfl ow and Upfl ow Installations NOTES:  Return Air and Filtering Systems � Before installing this furnace, consider all  Furnaces may be installed with unducted or  clearances for the installation and fut
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        3. Install 240V supply circuit(s) and 24V wir- Applications and Furnace  ing to closet (see Figure 16 for appropriate  Installation locations). NOTE: Remove refrigerant line knockouts in  4. Position optional coil cabinet over fl oor cutout  furnace only when installing indoor coil of an  and secure with three or more fasteners. air conditioning or heat pump system. 5. Position furnace onto coil cabinet and secure  with two or more fasteners. Refer to instructions supplied with accessory  6. Use 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        REAR WALL OF ENCLOSURE CENTER LINE 1 3/4" MIN (45 mm) 17 1/2" Furnace  18 5/8" (445 mm) Outline (474 mm) 14" (356 mm) 23 3/4" (604 mm) 3 1/8" (80 mm) For Optional A/C Or H/P 3/4" (20 mm) 5 3/4" 3" (147 mm) (73 mm) Furnace  20" Outer Door (508 mm) Figure 19.  Upfl ow Floor Cutout Locations (nominal dimensions) � -010 model is factory-wired for single-branch  Connecting Supply Service Wires supply circuit only. 1. Remove right-hand control panel (when  � -012 models are factory-wired for single- vi
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        ON ON 60A 60A OFF OFF ON ON 60A 60A OFF OFF 6. Connect service ground wire(s) to grounding 5. Install new blower ensuring the side fl anges  lug(s) provided.  One ground is required for engage under side mounting tabs (three on  each supply circuit used. one side, one on the other) and the long tab  in the rear. 6. Replace screws previously removed from  blower.  WARNING: 7. Connect the motor plug to the control panel  To avoid personal injury or property  receptacle. damage, make certain that th
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        terminal 4 on blower relay and is the blue wire  attached to the motor pin terminals 1-3.  IMPORTANT: a. Remove heating and cooling leads from  If a relay box is installed, blower  motor terminals 1-5. speeds for heating and cooling are set  b. Choose desired speeds and seat terminal  inside the relay box (see instructions  back into motor terminals 1-5. included with relay box).  The blower  speed inside the furnace control box Same Speed, Heating and A/C: Use loose  white jumper wire supplied