ملخص المحتوى في الصفحة رقم 1
INSTALLATION &
OPERATION
MANUAL
Versa Drawer™
Refrigeration Units
Please read this manual completely
before attempting to install or operate
this equipment! Notify carrier of damage.
Inspect all components immediately.
Delfield 980 S. Isabella Rd., Mt. Pleasant, MI 48858
+1 (989) 773-7981 or (800) 733-8829 • Fax (866) 779-2040
www.delfield.com July 2010
ملخص المحتوى في الصفحة رقم 2
Versa Drawer™ Refrigeration Units IMPORTANT WARNING AND SAFETY INFORMATION Read this manual thoroughly before operating, installing, or performing maintenance on the equipment. FAILURE TO FOLLOW INSTRUCTIONS IN THIS MANUAL CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. UNLESS ALL COVER AND ACCESS PANELS ARE IN PLACE AND PROPERLY SECURED,
ملخص المحتوى في الصفحة رقم 3
Versa Drawer™ Refrigeration Units Table of Contents SAFETY PRECAUTIONS .........................................................................................2 RECEIVING AND INSPECTING THE EQUIPMENT ................................................4 SPECIFICATIONS ....................................................................................................4 Serial Number ......................................................................................................4 INSTALLA
ملخص المحتوى في الصفحة رقم 4
Versa Drawer™ Refrigeration Units RECEIVING AND INSPECTING THE EQUIPMENT Even though most equipment is shipped crated, care 4. Request an inspection by the shipping company should be taken during unloading so the equipment is of the damaged equipment. This should be done not damaged while being moved into the building. within 10 days from receipt of the equipment. 1. Visually inspect the exterior of the package and 5. Check the lower portion of the unit to be sure legs skid or container.
ملخص المحتوى في الصفحة رقم 5
Versa Drawer™ Refrigeration Units SPECIFICATIONS (230-240V/50Hz) Freestanding Models # of Ref. Ship Model L D H Volts HZ Amps HP Plug Drawers Charge Weight 50" 31.5" 34" 2 230-240 50 3.6 1/3 BS1373 850.5g 236kg 18650VDR-CE 127.0cm 80.0cm 86.4cm 50" 31.5" 34" 18650VDL-CE 2 230-240 50 3.6 1/3 BS1373 850.5g 236kg 127.0cm 80.0cm 86.4cm 82" 31.5" 34" 4 230-240 50 7.2 (2) 1/3 BS1373 (2) 850.5g 327kg 18682VDR-CE 208.3cm 80.0cm 86.4cm 82" 31.5" 34" 18682VDL-CE 4 230-240 50 7.2 (2) 1/3 BS1373 (2) 850.5
ملخص المحتوى في الصفحة رقم 6
Versa Drawer™ Refrigeration Units ELECTRICAL CONNECTION INSTALLATION ELECTRICAL CONNECTIONS AND GROUNDING Never stand on the unit or its drawers! Doing so may CONNECTIONS MUST COMPLY WITH THE result in bodily injury. APPLICABLE PORTIONS OF THE NATIONAL LOCATION ELECTRICAL CODE AND/OR OTHER LOCAL Units represented in this manual are intended for ELECTRICAL CODES. indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of
ملخص المحتوى في الصفحة رقم 7
Versa Drawer™ Refrigeration Units Internet Info OPERATION The Versa Drawer unit has the capability to be GENERAL monitored remotely using the Internet. Using NAFEM Each drawer operates independently in one of four protocol to monitor HACCP information such as cabinet modes at any time: and evaporator temperature as well as other key data Refrigerator mode The drawer operates at a set can be view live or past data can be pulled up. point of 37°F (3°C), maintaining a range between 34°F
ملخص المحتوى في الصفحة رقم 8
Versa Drawer™ Refrigeration Units OPERATION OPERATING CONTROLS All operating functions are accessible on the Versa Drawer control panel. Operators can select the drawer modes or activate the manual defrost. Access to all diagnostic functions require a qualified service technician. 2-Drawer Interface Control Buttons are located next to the drawer display on 3 1 the Control Panel. The drawer select buttons select the drawer to be configured. 2 4 These arrows are used to change a drawer to
ملخص المحتوى في الصفحة رقم 9
Versa Drawer™ Refrigeration Units Cleaning the Condenser Coil The condenser coil requires regular cleaning, THE UNIT MUST BE DISCONNECTED FROM recommended is every 90 days. In some instances THE POWER SOURCE WHENEVER PERFORMING you may find that there is a large amount of debris and SERVICE, MAINTENANCE FUNCTIONS OR dust or grease accumulated prior to the 90-day time CLEANING THE REFRIGERATED AREA. frame. In these cases the condenser coil should be cleaned as needed.
ملخص المحتوى في الصفحة رقم 10
Versa Drawer™ Refrigeration Units Reassembly PREVENTIVE MAINTENANCE Push the drawer tracks into the drawer cage. The blue Gasket Maintenance safety clip must remain pushed towards the back. Gaskets require regular cleaning to prevent mold and Lift up and slide the drawer track all the way into the mildew build up and also to keep the elasticity of the drawer cage. The blue safety clip will lock in place gasket. Gasket cleaning can be done with the use of automatically. Once all tracks ar
ملخص المحتوى في الصفحة رقم 11
Versa Drawer™ Refrigeration Units 2-Drawer Refrigeration Schematic Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-8829 · Fax (989) 773-3210 0 NOTE: The four drawer unit has two of these exact systems.
ملخص المحتوى في الصفحة رقم 12
Versa Drawer™ Refrigeration Units 2-Drawer Wiring Schematic Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (800) 733-882
ملخص المحتوى في الصفحة رقم 13
Versa Drawer™ Refrigeration Units 2-Drawer Wiring Schematic Delfield · 980 S. Isabella Road, Mt. Pleasant, MI 48858 · (989) 773-7981 or (80
ملخص المحتوى في الصفحة رقم 14
Versa Drawer™ Refrigeration Units 4-Drawer Wiring Schematic
ملخص المحتوى في الصفحة رقم 15
Versa Drawer™ Refrigeration Units 4-Drawer Wiring Schematic
ملخص المحتوى في الصفحة رقم 16
Versa Drawer™ Refrigeration Units Versa Drawer™ Alarm Alarm Meaning Action Alternate Action Thaw Finished Thaw cycle is complete and Press corresponding drawer unit is now in refrigeration number to clear audio and mode. screen. Chiller Finished Chiller cycle has completed Press corresponding drawer and unit is now in number to clear audio and refrigeration mode. screen. Drawer Open Drawer's been open for Close drawer. greater than set time. Drawer temperature Out of Drawer temperature's be
ملخص المحتوى في الصفحة رقم 17
Versa Drawer™ Refrigeration Units STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT UNDER WARRANTY Advice and recommendations given by Delfield A maximum travel distance of 100 miles round trip and Service Technicians do not constitute or guarantee any 2-hours will be reimbursed. special coverage. Overtime, installation/start-up, normal control A maximum of 1-hour is allowed to diagnose a adjustments, general maintenance, glass breakage, defective component. fre
ملخص المحتوى في الصفحة رقم 18
Versa Drawer™ Refrigeration Units STANDARD ONE YEAR WARRANTY (ONE YEAR PARTS AND LABOR.) The Delfield Company (“Delfield”) warrants to the Original Purchaser of the Delfield product (herein called the “Unit”) that such Unit, and all parts thereof, will be free from defects in material and workmanship under normal use and service for a period of one (1) year from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty card completely filled
ملخص المحتوى في الصفحة رقم 19
Versa Drawer™ Refrigeration Units The Delfield Company SERVICE LABOR CONTRACT T he Delfield Company (“Delfield”) offers this service labor contract (the “Service Labor Contract”), available at a nominal fee at the time of submission and acceptance of the order for the above listed Delfield unit (the “Unit”), in accordance with the following terms and conditions: The Service Labor Contract is in addition to Delfield’s Standard One Year Limited Warranty (the “One Year Warranty”) and Delfield
ملخص المحتوى في الصفحة رقم 20
Versa Drawer™ Refrigeration Units The Delfield Company (continued from previous page) Upon review and approval of the claim by Delfield’s Customer Service Department, payment will be made promptly only for the following costs: 1) Cost of service labor necessary to repair the Unit, provided that it is based on straight time only and the duration is, in the sole judgment of Delfield, within reason for the repair made. 2) Travel mileage of the service agency called upon to make the repair, prov