DRYER INSTALLATION INSTRUCTIONS
GAS (U.S.A. AND CANADA)
ELECTRIC (CANADA ONLY)
INSTRUCTIONS D'INSTALLATION DE LA SÉCHEUSE
À GAZ (É.-U. ET CANADA)
ÉLECTRIQUE (CANADA UNIQUEMENT)
Para una version de estas intrucciones en Español, visite www.Whirlpool.com
TABLE OF CONTENTS TABLE DES MATIÈRES
DRYER SAFETY..............................................................................2 SÉCURITÉ DE LA SÉCHEUSE ....................................................17
INSTALLATION REQUIREMENTS.............
ملخص المحتوى في الصفحة رقم 2
DRYER SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don't immediately DANG
ملخص المحتوى في الصفحة رقم 3
IMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1. The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. WARNING: For your safety, the information in this manual must be followed to minimi
ملخص المحتوى في الصفحة رقم 4
In the State of Massachusetts, the following installation instructions apply: ■ Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts. ■ If using a ball valve, it shall be a T-handle type. ■ A flexible gas connector, when used, must not exceed 3 feet. INSTALLATION REQUIREMENTS Steam Models Tools and Parts Gather the required tools and parts before starting installation. Read and follow the
ملخص المحتوى في الصفحة رقم 5
Dryer Dimensions Location Requirements D A B C Steam Non-Steam (Electric or Gas) (Electric or Gas) A 38" (965 mm) 38" (965 mm) You will need ■ A location that allows for proper exhaust installation. 9 1 B 32 /16" (827 mm) 31 /2" (800 mm) See “Venting Requirements.” C 27" (686 mm) 27" (686 mm) ■ A separate 15 or 20-amp circuit needed for gas dryers and 30-amp circuit needed for electric dryers. 9 1 D 52 /16" (1335 mm) 51 /2" (1308 mm) ■ If you are using a power supply cord, a grounded elect
ملخص المحتوى في الصفحة رقم 6
Closet installation - Dryer only (460 mm) C A* B C** B A* Side view Closet door with vents Side View Steam Non-Steam Steam Non-Steam (Electric or Gas) (Electric or Gas) (Electric or Gas) (Electric or Gas) A* 1" (25 mm) 1" (25 mm) A* 1" (25 mm) 1" (25 mm) 5 5 9 1 B 7 /8" (194 mm) 7 /8" (194 mm) B 32 /16" (827 mm) 31 /2" (800 mm) 3 3 C** 5" (127 mm) 5" (127 mm) C 3 /8" (86 mm) 3 /8" (86 mm) *Required spacing * Dimension A is approximate, depending on when the diamond marking on the leveling
ملخص المحتوى في الصفحة رقم 7
Recommended installation spacing for cabinet Recommended installation spacing for recessed or installation closet installation, with stacked washer and dryer NOTE: Some models are not recommended for cabinet installation. The dimensions shown are for the recommended spacing. ■ For cabinet installation, with a door, minimum ventilation 2 openings in the top of the cabinet are required. 48 in. * 2 (310 cm ) A* B* 3"* (76 mm) C* 3"* (76 mm) 2 24 in. * 1"* (25 mm) 2 (155 cm ) 6"* (152 mm) E G H D
ملخص المحتوى في الصفحة رقم 8
ELECTRIC DRYER POWER HOOKUP – CANADA ONLY For further information, please reference the service numbers located in the “Assistance or Service” section. Electrical Requirements GROUNDING INSTRUCTIONS WARNING ■ For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer is equipped with a cord having an equipment- groun
ملخص المحتوى في الصفحة رقم 9
GAS DRYER POWER HOOKUP 3 ■ If your dryer has been converted to use LP gas, /8" LP compatible copper tubing can be used. If the total length of the Gas Supply Requirements supply line is more than 20 ft (6.1 m), use larger pipe. NOTE: Pipe-joint compounds that resist the action of LP gas ®† WARNING must be used. Do not use TEFLON tape. ■ Must include a shutoff valve: In the U.S.A.: An individual manual shutoff valve must be installed within six (6) feet (1.8 m) of the dryer in accordance wit
ملخص المحتوى في الصفحة رقم 10
A 3. Open the shutoff valve in the supply line. The valve is open when Dryer gas pipe the handle is parallel to the gas pipe. A ■ The gas pipe that comes out through the rear of your dryer has a 3 /8" male pipe thread. B B *6¼" A. Closed valve (159 mm) B. Open valve 4. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak. Correct any leak found. 1½" (38 mm) A Electrical Requirements 1 A. /2" NPT gas supply line 3 B. /8" NP
ملخص المحتوى في الصفحة رقم 11
Flexible metal vent ■ Flexible metal vents are acceptable only if accessible for VENTING cleaning. ■ Flexible metal vent must be fully extended and supported when the dryer is in its final location. Venting Requirements ■ Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance. WARNING ■ Do not install flexible metal vent in enclosed walls, ceilings, or floors. ■ The total length of flexible metal vent should not exceed 7¾ ft.
ملخص المحتوى في الصفحة رقم 12
G ■ Do not use an exhaust hood with a magnetic latch. Improper venting can cause moisture and lint to collect indoors, which may result in: Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc. Housecleaning problems and health problems. A B C A. Standard rear offset exhaust installation Plan Vent System B. Left or right side exhaust installation C. Bottom exhaust installation Choose your exhaust installation type Alternate installations for close clearances Recommended exhau
ملخص المحتوى في الصفحة رقم 13
■ Plan the installation to use the fewest number of elbows 2. Firmly grasp the body of the dryer (not the console panel). Gently and turns. lay the dryer on the cardboard. See illustration. ■ When using elbows or making turns, allow as much room as possible. ■ Bend vent gradually to avoid kinking. ■ Use the fewest 90° turns possible. Determine vent length and elbows needed for best drying performance ■ Use the following vent system chart to determine type of vent material and hood combi
ملخص المحتوى في الصفحة رقم 14
4. Using pliers, tighten the couplings with an additional two-thirds turn. LEVEL DRYER Check the levelness of the dryer. Check levelness first side to side, then front to back. NOTE: Do not overtighten. Damage to the coupling can result. 5. Attach “Y” connector to brass male end of small hose. Screw on If the dryer is not level, prop up the dryer using a wood block. Use a coupling by hand until it is seated on connector. wrench to adjust the legs up or down and check again for levelness. 6.
ملخص المحتوى في الصفحة رقم 15
If you receive an L2 code, there may be a problem with your If you do not feel heat, turn off the dryer and check the home power supply keeping the dryer’s heater from turning on. following: See “Troubleshooting.” ■ There may be 2 household fuses or circuit breakers for the 16. When the dryer has been running for 5 minutes, open the dryer dryer. Check that both fuses are intact and tight, or that both door and feel for heat. If you feel heat, cancel cycle and close the circuit breakers have
ملخص المحتوى في الصفحة رقم 16
■ Is the exhaust vent the correct length? Check that the exhaust vent is not too long or has too many Dryer Results turns. Long venting will increase drying times. See the Installation Instructions. Clothes are not drying satisfactorily, drying times are too ■ Is the exhaust vent diameter the correct size? long, or load is too hot Use 4" (102 mm) diameter vent material. ■ Is the lint screen clogged with lint? ■ Is the dryer located in a room with temperature below 45ºF Lint screen shou
ملخص المحتوى في الصفحة رقم 17
SÉCURITÉ DE LA SÉCHEUSE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte de sécurit
ملخص المحتوى في الصفحة رقم 18
AVERTISSEMENT : L’odorat ne permet pas toujours la détection d’une fuite de gaz. Les distributeurs de gaz recommandent l’emploi d’un détecteur de gaz (homologation UL ou CSA). Pour d’autre information, contacter le fournisseur de gaz local. En cas de détection d’une fuite de gaz, exécuter les instructions “Que faire dans le cas d’une odeur de gaz”. IMPORTANT : L'installation du gaz doit se conformer aux codes locaux, ou en l'absence de codes locaux, au code canadien d'installation B149.1 du gaz
ملخص المحتوى في الصفحة رقم 19
EXIGENCES D'INSTALLATION Pièces nécessaires Consulter les codes locaux. Vérifier l'alimentation électrique et le Outillage et pièces circuit d'évacuation existants. Voir “Spécifications électriques “et” Rassembler les outils et pièces nécessaires avant de commencer Exigences concernant l'évacuation” avant d'acheter les pièces. l'installation. Lire et suivre les instructions fournies avec les outils Les installations pour maison mobile nécessitent un système indiqués ici. d'évacuation en mét
ملخص المحتوى في الصفحة رقم 20
Ne pas faire fonctionner la sécheuse à des températures Dimensions pour l'évacuation inférieures à 45°F (7°C). À des températures inférieures, la sécheuse risque de ne plus s'arrêter à la fin d'un programme automatique. Les temps de séchage risquent alors d'augmenter. La sécheuse ne doit pas être installée ou remisée dans un endroit où elle sera exposée à l'eau et/ou aux intempéries. Vérifier les règlements locaux. Certains codes limitent ou n'autorisent pas l'installation des sécheuses d