ملخص المحتوى في الصفحة رقم 1
C
E
N
R
G
T
I
To contact LG Electronics, 24 hours a day,
7 days a week:
1-800-243-0000
Or visit us on the Web at: us.lge.com
TM
Número telefónico de LG Electronics, las 24
STEAM DRYER
horas del día, 7 días a la semana:
1-800-243-0000
USER’S GUIDE &
O visítenos en la Web en: us.lge.com
INSTALLATION INSTRUCTIONS
To contact LG Electronics, 24 hours a day,
7 days a week :
Before beginning installation, read these
instructions carefully. This will simplify installation
1-888-LGCANADA
and e
ملخص المحتوى في الصفحة رقم 2
IINTR N T RODUCTION O D U C T I O N IMPORTANT SAFETY INSTRUCTIONS Basic Safety Precautions ....................................... 3 What to Do if You Smell Gas .................................. 4 Grounding Instructions ........................................... 5 Safety Instructions for Installation ...................... 5, 6 THANK YOU! THANK YOU! Safety Instructions for Steam Functions ................ 6 Safety Instructions for Connecting Electricity ....... 7 Congratulations on your purch
ملخص المحتوى في الصفحة رقم 3
IMPOR I M P O RT TANT SAFETY INSTR A N T S A F E T Y I N S T RUCTIONS U C T I O N S READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be followed to minimize the risk of fi re or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. Your Safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages
ملخص المحتوى في الصفحة رقم 4
IIMPOR M P O RT TA ANT SAFETY INSTR N T S A F E T Y I N S T RU UCTIONS C T I O N S READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be followed to minimize the risk of fi re or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. • Do not store or use gasoline or other • Installation and service must be fl ammable vapors and liquids in the performed by a qualifi ed installer, vicinity of this appliance or any
ملخص المحتوى في الصفحة رقم 5
IMPOR I M P O RT TANT SAFETY INSTR A N T S A F E T Y I N S T RUCTIONS U C T I O N S READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be followed to minimize the risk of fi re or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. GROUNDING INSTRUCTIONS This appliance must be grounded. In the event Do not modify the plug provided with the of malfunction or breakdown, grounding will appliance. If it will not fi
ملخص المحتوى في الصفحة رقم 6
IMPOR I M P O RT TA ANT SAFETY INSTR N T S A F E T Y I N S T RU UCTIONS C T I O N S READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be followed to minimize the risk of fi re or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. SAFETY INSTRUCTIONS FOR INSTALLATION Exhaust/Ducting: Gas dryers MUST be exhausted to the The exhaust duct must be 4 in. (10 cm) in outside. Failure to follow these instructions
ملخص المحتوى في الصفحة رقم 7
IMPOR I M P O RT TANT SAFETY INSTR A N T S A F E T Y I N S T RUCTIONS U C T I O N S READ ALL INSTRUCTIONS BEFORE USE wWARNING For your safety, the information in this manual must be followed to minimize the risk of fi re or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. SAFETY INSTRUCTIONS FOR CONNECTING ELECTRICITY wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, includi
ملخص المحتوى في الصفحة رقم 8
P PA A R RTS AND FEA T S A N D F E ATURES T U R E S SPECIAL FEATURES EASY-TO-USE CONTROL PANEL 1 4 1 Rotate the Cycle Selector Knob to select the desired dry cycle. Add cycle options or adjust 5 settings with the touch of a button. 6 2 EASY-ACCESS REVERSIBLE DOOR Wide-opening door provides easy access for loading and unloading. Door swing can be 3 reversed to adjust for installation location. ULTRA-CAPACITY STAINLESS STEEL DRUM 3 WITH DRUM LIGHT The ultra-large stainless steel drum offer
ملخص المحتوى في الصفحة رقم 9
P PA A R RT TS AND FEA S A N D F E ATURES T U R E S KEY PARTS AND COMPONENTS In addition to the special features and components outlined in the Special Features section, there are several other important components that are referenced in this manual. 1 FRONT-MOUNT LINT FILTER Front-mounted lint filter allows for easy access and cleaning after every load. 2 LEVELING FEET Four leveling feet (two in the front, and two in the back) adjust to improve dryer stability on uneven floors. 3 PLC MODE
ملخص المحتوى في الصفحة رقم 10
INST I N S TA ALLA L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S IMPORTANT: Read all installation instructions completely before installing and operating your dryer! It is important that you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are provided on the following pages. CHOOSE THE PROPER LOCATION Properly ground dryer to conform with all Store and install the
ملخص المحتوى في الصفحة رقم 11
INST I N S TALLA A L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACKING KIT IMPORTANT: If you are installing your dryer using an optional pedestal base or stacking kit, please refer to Optional Accessories in this manual or to the instructions for your pedestal or stacking kit before proceeding with the installation. Required Dimensions for Installation Required Dimensions for Installation With Pedestal With Stacking Kit 1 77 /2"
ملخص المحتوى في الصفحة رقم 12
INST I N S TA ALLA L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S LEVELING THE DRYER All four leveling feet must rest solidly on the WARNING w floor. Gently push on the top corners of the Wear gloves during installation. dryer to make sure that the dryer does not Failure to follow these instructions can result in injury. rock from corner to corner. If you are installing the dryer on the optional To ensure that the dryer provides optimal drying pedestal, you must
ملخص المحتوى في الصفحة رقم 13
INST I N S TALLA A L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S CHANGING THE DRYER VENT LOCATION WARNING Retaining w Screw Use a heavy metal vent. Do not use plastic or thin foil duct. Clean old ducts before installing this dryer. Wear gloves during installation. Failure to follow these instructions can result in death or fi re. Your new dryer is shipped to vent to the rear. Rear Exhaust Duct It can also be configured to vent to the bottom or side (right-side vent
ملخص المحتوى في الصفحة رقم 14
INST I N S TALLA A L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S VENTING THE DRYER wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following: Do not crush or collapse ductwork. Failure Rigid or semirigid metal ducting is to follow these instructions can result in fi re recommended for use between the dryer or death. and the wall. In special installations when it is impossible to make a
ملخص المحتوى في الصفحة رقم 15
IINST N S TALLA A L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S VENTING THE DRYER (cont.) Ductwork Number of Max. Length of 4-In. Dia. Max. Length of 4-In. Dia. Wall Cap Type 90° Elbows Rigid Metal Duct Flexible Metal Duct 0 65 ft. (19.8 m) 45 ft. (13.7 m) Recommended 1 55 ft. (16.8 m) 35 ft. (10.7 m) 2 47 ft. (13.7 m) 30 ft. (9.1 m) 3 36 ft. (11.0 m) 25 ft. (7.6 m) 4" 4" (10.2 cm) (10.2 cm) 4 28 ft. (8.5 m) 20 ft. (6.1 m) 0 55 ft. (16.8 m) 35 ft. (10.7 m) Use Only fo
ملخص المحتوى في الصفحة رقم 16
INST I N S TA ALLA L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S CONNECTING GAS DRYERS wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following: Gas supply requirements: Connect the dryer to the type of gas shown on As shipped from the factory, this dryer is the nameplate. Failure to do so can result in fi re, confi gured for use with natural gas. It can be explosion, or death. converted
ملخص المحتوى في الصفحة رقم 17
INST I N S TALLA A L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S CONNECTING GAS DRYERS (cont.) wWARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following: Installation and service must be performed If necessary, the correct nozzle (for the LP by a qualifi ed installer, service agency, or the nozzle kit order part number 4948EL4002B) gas supplier. Failure to do so can result in fi re, should
ملخص المحتوى في الصفحة رقم 18
INST I N S TA ALLA L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S CONNECTING ELECTRIC DRYERS wWARNING: To help prevent fire, electric shock, serious injury, or death, the wiring and grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70 and all applicable local regulations. Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has adequate electrical power to operate the dryer. Electrical Requirements
ملخص المحتوى في الصفحة رقم 19
INST I N S TALLA A L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S CONNECTING ELECTRIC DRYERS (cont.) USA ONLY wWARNING: • Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload. • Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile h
ملخص المحتوى في الصفحة رقم 20
INST I N S TA ALLA L L ATION INSTR T I O N I N S T RUCTIONS U C T I O N S CONNECTING ELECTRIC DRYERS (cont.) USA ONLY wWARNING: • Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow these instructions may result in a short or overload. • Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile h