ملخص المحتوى في الصفحة رقم 1
INSTALLATION &
OPERATION MANUAL
VCB25, VCB36, VCB47 SERIES
CHARBROILERS
MODELS
VCB25S ML-44908Z
VCB25M ML-44963Z
VCB36 ML-44966
VCB36S ML-44909Z
VCB36C ML-44967
VCB36M ML-44964Z
VCB47S ML-44910Z
VCB47M ML-44965Z
Model VCB36C
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791
FORM 31167 (Jan. 2001) – 1 –
ملخص المحتوى في الصفحة رقم 2
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS
ملخص المحتوى في الصفحة رقم 3
INSTALLATION, OPERATION AND CARE OF MODEL VCB SERIES CHARBROILERS PLEASE KEEP THIS MANUAL FOR FUTURE USE GENERAL Vulcan-Hart Charbroilers are produced with quality workmanship and material. Proper installation, usage and maintenance of your charbroiler will result in many years of satisfactory performance. It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions provided. INSTALLATION Before installing, verify that the type of gas supply (natural o
ملخص المحتوى في الصفحة رقم 4
Floor models must clear 6" (15 cm) from combustible oors. It is recommended that the charbroiler NOT be installed next to open burners or fryers. The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 24" (61 cm) is required. Do not obstruct the ow of combustion and ventilation air. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room to repla
ملخص المحتوى في الصفحة رقم 5
GAS CONNECTIONS CAUTION: Gas supply connections and any pipe joint compound must be resistant to the action of propane gases. Location of the gas inlet is at the right rear corner. Codes require that a gas shutoff valve must be installed in the gas line ahead of the charbroiler. Connect gas supply to the charbroiler. Make sure the pipes are clean and free of obstructions. 3 The gas supply line must be /4" or larger. If flexible or semi-rigid connections are used, the inside 3 diameter must be
ملخص المحتوى في الصفحة رقم 6
OPERATION WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE CHARBROILER. CONTROLS Gas Valves — Regulate gas flow to the burners. Pilot Adjusting Valve — Regulates gas flow to pilot burner. Gas Pressure Regulator — Regulates gas pressure to the burners. LIGHTING INSTRUCTIONS 1. Turn gas shutoff valve and burner gas valves to the OFF position and wait 5 minutes. 2. Turn the gas shutoff valve to the ON position. 3. Turn pilot valve adjusting
ملخص المحتوى في الصفحة رقم 7
The charbroiler is a free-vented appliance. All the products of combustion and the heat generated by the burners pass through the grates. When meat is placed on the grates, you are blocking the venting, thus causing a temperature build-up. The charbroiler, with a complete load, will operate most efficiently 1 1 with burners turned down /3 to /2. DRIP PAN DO NOT allow the drip pan to overflow. Empty the drip pan when three-quarters full to reduce the possibility of spillage. CLEANING Daily Th
ملخص المحتوى في الصفحة رقم 8
MAINTENANCE WARNING: THE CHARBROILER AND ITS PARTS ARE HOT. BE VERY CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE CHARBROILER. LUBRICATION All moving parts must be checked for wear and lubricated. Contact your local Vulcan authorized servicer. All valves and controls should be lubricated with a high temperature grease by your local Vulcan authorized servicer. PILOT LIGHTS Pilot lights are to be kept clean and adjusted. RECOMMENDED SERVICE FREQUENCY Frequency of service maintenance will be