ملخص المحتوى في الصفحة رقم 1
Digital Automatic Blood Pressure Monitor
Model M10-IT
EN
• Instruction Manual
FR
• Mode d’emploi
DE
• Gebrauchsanweisung
IT
• Manuale di istruzioni
ES
• Manual de instrucciones
NL
• Gebruiksaanwijzing
RU
•
AR
•
IM-HEM-7080IT-E-07-09/2012
1663794-1I
ملخص المحتوى في الصفحة رقم 2
Contents Before using the unit Introduction .................................................................................3 Important Safety Information.....................................................4 1. Overview ................................................................................6 2. Preparation ..........................................................................10 2.1 Installing/Replacing the Batteries ...............................................10 2.2 Setting t
ملخص المحتوى في الصفحة رقم 3
Before using the unit Introduction Introduction Thank you for purchasing the OMRON M10-IT Intellisense Upper Arm Blood Pressure Monitor. The OMRON M10-IT Intellisense is a fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need for pressure pre-setting or re- inflation the device uses its advanced “Intellisense” technology. The monitor stores me
ملخص المحتوى في الصفحة رقم 4
Important Safety Information Important Safety Information Consult your doctor during pregnancy, arrhythmia and arteriosclerosis. Use the unit only to store the designated users measurement results. Please read this section carefully before using the unit. Caution: (General Usage) • Always consult your doctor. You should never stop or change the dosage of medication prescribed by your doctor. • Do not leave the unit unattended with infants or persons who cannot express their consent. • Do n
ملخص المحتوى في الصفحة رقم 5
Important Safety Information • Never plug in or unplug the power cord from the electric outlet with wet hands. (Battery Usage) • If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Consult a doctor immediately. • If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water. • Use only four “AA” alkaline batteries with this unit. Do not use other types of batteries. • Do not insert the batteries with their polarit
ملخص المحتوى في الصفحة رقم 6
1. Overview 1. Overview Main Unit A H G F E B C J D I A. Display H. Battery compartment B. SET button I. Air jack C. Morning/Evening Average J. AC adapter jack (for AC ( / ) buttons adapter) D. MEMORY button E. USB connector jack (USB 1.1 compatible) F. O/I START button G. User ID selection switch (A & B) 6
ملخص المحتوى في الصفحة رقم 7
1. Overview Arm Cuff K L M K. Arm cuff (Cuff: arm circumference 22-42 cm) L. Air Plug M. Air Tube EN 7
ملخص المحتوى في الصفحة رقم 8
1. Overview Display N V W O X P Y Q Z R AA S AB T AC U AD N. Systolic blood pressure V. User ID symbol (A or B) (Indicates user A or user B as O. Diastolic blood pressure selected by the user to take a P. Heartbeat symbol measurement or when using 1. (Flashes during measurement) the memory function.) 2. (If flashing after measurement W. Pulse display completed indicates blood X. Early morning hypertension pressure out of recommended symbol range) (Displayed if the morning Q. Movement sym
ملخص المحتوى في الصفحة رقم 9
1. Overview Package Contents AE AF AG AH AE.Soft storage bag • Instruction manual AF.Four “AA” alkaline (LR6) • Guarantee card batteries • Blood pressure pass AG.USB cable • Blood Pressure Monitor unit AH.CD-ROM (Blood pressure • Installation guide (for Blood management software) EN pressure management software) 9
ملخص المحتوى في الصفحة رقم 10
2. Preparation 2. Preparation 2.1 Installing/Replacing the Batteries 1. Turn the main unit upside down. 2. Slide the battery cover in the direction of the arrow while pressing the ribbed part of the cover. 3. Install or replace four “AA” size batteries so that the + (positive) and - (negative) polarities match the polarities indicated on the battery compartment. 4. Put the battery cover back in place. Slide the battery cover as indicated, until it clicks into place. Note: The measurement
ملخص المحتوى في الصفحة رقم 11
2. Preparation Battery Life & Replacement If the battery low symbol ( ) appears on the display, replace all four batteries at the same time. - When the battery low symbol ( ) starts to blink, you will still be able to use the unit for a short while. You should replace the batteries with new ones ahead of time. - When the symbol ( ) remains lit, the batteries are exhausted. You should replace the batteries with new ones at once.Turn the unit off before replacing the batteries. • Remove the b
ملخص المحتوى في الصفحة رقم 12
2. Preparation 2.2 Setting the Date and Time Your blood pressure monitor automatically stores up to 84 individual measurement values with the date and time. To make use of the memory and average values functions: • Set the unit to the correct date and time before taking a measurement for the first time. • If the batteries have been removed for more than 30 seconds, the Date/Time setting will need to be reset. 1. When the O/I START button is pressed to turn the unit on for the first time a
ملخص المحتوى في الصفحة رقم 13
2. Preparation 4. Repeat steps 2 and 3 to set the month. The month is set and the day digits flash on the display. 5. Repeat steps 2 and 3 to set the day. The day is set and the hour digits flash on the display. 6. Repeat steps 2 and 3 to set EN the hour. The hour is set and the minutes digits flash on the display. 13
ملخص المحتوى في الصفحة رقم 14
2. Preparation 7. Repeat steps 2 and 3 to set the minutes. The minutes settings is set. The unit automatically turns itself off after the minute setting has been set. To adjust the date and time, press the SET button while the unit is in standby mode. Notes on Adjusting the Date and Time Setting If you need to adjust the date and time for some reason, or if the date and time has been reset after replacing the batteries, adjust the date and time between 10:00 and 18:59. This will avoid pr
ملخص المحتوى في الصفحة رقم 15
2. Preparation 2. Refer to Chapter 2.2.2 to start setting the date and time. With this manual setting of date and time the unit needs to be manually shut off. It will not automatically turn off after the minutes have been set. Notes: • Please ensure that the date and time have been set correctly so that the weekly averages will be displayed correctly. If the Date/Time settings have been accidentally set incorrectly, press the SET button to circle through the settings in order to adjust to t
ملخص المحتوى في الصفحة رقم 16
Operating instructions 3. Using the Unit 3. Using the Unit 3.1 How to Sit Correctly When Taking a Measurement You can take a measurement on either your left or right arm. Notes: • Measurements should be taken in a quiet place and you should be in a relaxed, seated position. Make sure that the room is not too hot or cold. • Avoid eating, smoking, or exercising for at least 30 minutes before taking a measurement. • Do not move or talk during measurement. Correct Remove tight fitting clothing f
ملخص المحتوى في الصفحة رقم 17
3. Using the Unit Notes: • Correct posture during measurement is necessary to get accurate results. • You should also try to measure your blood pressure at the same time each day. (Within 1 hour after waking up is recommended.) Incorrect Posture • Arched back (leaning forwards) • Sitting cross-legged • Sitting on a sofa or at a low table so that you tend to lean forward These situations could lead to higher blood pressure values due to strain or the arm cuff being lower than the heart. If
ملخص المحتوى في الصفحة رقم 18
3. Using the Unit 3.2 Applying the Arm Cuff You can wrap the cuff either on your right or left arm. • Remove tight-fitting clothing from your upper arm. • Do not place the cuff over thick clothes and do not roll up your sleeve if it is too tight. 1. Insert the air plug into the air jack (on the left side of the device). Air jack Air plug The cuff must be fully deflated when it is inserted into the air jack. 2. Sit in a chair with your feet flat on the floor and place your arm on a table so
ملخص المحتوى في الصفحة رقم 19
3. Using the Unit 3. Hold the grip on the cuff securely Grip with your hand. Fabric fastener 4. Turn the palm of your hand upward. 5. Apply the cuff to your upper arm so that the blue strip is centred on the middle of your inner arm and points down the inside of the arm. The air tube should run down the inside of your forearm and be in line with your middle finger. The bottom of the cuff should be approximately 1 to 2 cm above the elbow. Bottom edge 1 to 2 cm Blue strip EN Air tube 19
ملخص المحتوى في الصفحة رقم 20
3. Using the Unit 6. When the cuff is positioned correctly, close the fabric fastener FIRMLY. Notes: • Make certain the cuff fits snugly around your arm. • The cuff should make good contact with your skin. You should be able to fit your index finger between the cuff and your arm easily, so you can pull the cuff off and on. • Make sure that there are no kinks in the air tubing. Taking measurements on the right arm Please note the following points when applying the cuff to your right arm. App