ملخص المحتوى في الصفحة رقم 1
™
Clean & Clear Filter System Owner's Manual
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Table of Contents
SECTION I. PUMP SAFETY INSTRUCTIONS ------------------------------------------------------- 2
SECTION II. HOW YOUR FILTER WORKS----------------------------------------------------------- 2
SECTION III. CHECK V ALVE INSTALLA TION INSTRUCTIONS ----------------------------------- 3
SECTION IV . INSTALLATION -------------------------------------------
ملخص المحتوى في الصفحة رقم 2
SECTION I. PUMP SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. 3. WARNING - Risk of Electrical Shock. Connect only to a grounding type receptacle protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified el
ملخص المحتوى في الصفحة رقم 3
WARNING Failure to operate your filter system or inadequate filtration can cause poor water clarity obstructing visibility in your pool. Poor water clarity may obscure objects in the water which while swimming and diving could cause severe personal injury and death. Never swim in a pool with poor water clarity. SECTION III. CHECK VALVE INSTALLATION INSTRUCTIONS WARNING THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK RING, PUMP, FILTER, VALVES, ETC.)
ملخص المحتوى في الصفحة رقم 4
6. Insert the Check Valve into the outlet port approximately 3/4" to 1" deep making sure the rubber diaphragm facing outward (towards you), see Diagram 1. 7. Reconnect the return hose to the outlet port and tighten the union fitting. 8. Replace the drain cap. 9. Remove the rag from the skimmer or open the valve on the suction line. 10. If the return line was plugged, unplug it at this time. Diagram 1. 11. With the High Flow™ manual air relief valve in the open position, start the filter pump, af
ملخص المحتوى في الصفحة رقم 5
5. Do not mount electrical controls (on/off switches, timer, etc.) over the filter. You need to be able to stand clear of the filter when starting the pump. 6. Attach the hair and lint pot to the front of the pump. This is an O-ring seal fitting that requires hand tightening only. (OVER TIGHTENING CAN RESULT IN DAMAGE TO THE O-RING SEAL) 7. Install the threaded fitting, see Diagram 3 – Figure 1, into the suction port of the pump. This is an O-ring seal fitting that requires hand tightening only.
ملخص المحتوى في الصفحة رقم 6
SECTION V. INITIAL START-UP AND RESTART INSTRUCTIONS. 1. Be sure all connections have been made and are secure. 2. Make sure the hair and lint pot of the pump is filled with water. (FAILURE TO FILL THE HAIR AND LINT POT WITH WATER WILL RESULT IN DAMAGE TO THE PUMP AND PUMP SEAL). 3. OPEN THE HIGH FLOW MANUAL AIR RELIEF VALVE UNTIL IT SNAPS INTO THE FULL OPEN POSITION (THIS ONLY REQUIRES A 1/4 TURN COUNTERCLOCKWISE). 4. STAND CLEAR OF THE FILTER. Start pump allowing the filter tank to fill with w
ملخص المحتوى في الصفحة رقم 7
8. Remove the CARTRIDGE ELEMENT assembly from the filter body by using the lifting handles and pulling straight up. 9. Remove the CARTRIDGE ELEMENT from the core assembly by placing your middle fingers into cloth area and using your thumbs on top of the lifting handles and pressing until the CARTRIDGE ELEMENT is loose and freely slides off the center core assembly. 10. Using a garden hose, direct water spray at the CARTRIDGE ELEMENT to dislodge and wash away any accumulated foreign matter and Di
ملخص المحتوى في الصفحة رقم 8
SECTION VII. WINTERIZING THE FILTER 1. In areas that have freezing winter temperatures, the pool equipment must be winterized to protect it from damage. 2. With the pump turned off, open the High Flow™ manual air relief valve. 3. Remove the drain port cap, and allow the filter to drain completely. 4. Remove the drain port plugs on the pump and allow the pump to drain completely. 5. Drain all appropriate system piping. 6. It is recommended that the pump and filter be covered with a tarpaulin or p
ملخص المحتوى في الصفحة رقم 9
SECTION IX. TROUBLE SHOOTING Problem Cause Remedy Pool water not 1. Pool chemistry not adequate to inhibit algae growth. Maintain pool chemistry or consult pool service technician. sufficiently clean. 2. Inadequate turnover rate. Run system for longer time or consult dealer or pool service technician. Higher filter pressure. 1. Insufficient cleaning of the filter element. Clean the filter element (see Cleaning Filter instructions). 2. Partially closed valve or restriction. Open valve or remove o
ملخص المحتوى في الصفحة رقم 10
3. SHAFT SEAL - (rotary seal). The shaft seal consists of two parts: a. Rotating ceramic seal, press fitted into the impeller. b. A stationary spring loaded seal, press fitted into the rear of the volute. 4. THE ELECTRIC MOTOR. a. The electric motor should be protected from foreign matter, water splashing, hosing, and the weather. Enclosures should be well ventilated to prevent overheating. If a motor becomes wet, permit it to dry before running it. If a motor has been damaged by water or dirt,
ملخص المحتوى في الصفحة رقم 11
SECTION XI. TECHNICAL DATA A. FILTER AND TANK Replacement Parts Find Part Description No. No. 1 98209800 High Flow Manual Air Relief Valve 2 53003201 Pressure Gauge 3 178553 Lid, 50/100 Sq./Ft. 3 178561 Lid, 75 Sq./Ft. 4 59052900 Locking Ring Assy. 5 87300400 Body O-ring 6 59016200 Air Bleed Sock Kit 7 59053500 Center Core, 50 Sq./Ft. 7 59053600 Center Core, 75 Sq./Ft. 7 59053700 Center Core, 100 Sq./Ft. 8 59054000 Cartridge Element, 50 Sq./Ft. 8 59054100 Cartridge Element, 75 Sq./Ft. 8 5905420
ملخص المحتوى في الصفحة رقم 12
SECTION XI. TECHNICAL DATA (continued) B. MAXIM PUMP 11 10 9 3 6 13 4 8 7 2 1 12 14 5 2 1 Replacement Parts Find Part Description Find Part Description No. No. No. No. 98215000 No.10 lock washer, internal star 1 98206400 Plug, ¼ in. with O-ring 2 57006500 O-ring 98215200 Nut, hex, 10-24 Maxim pump 3 39102503 Volute, S Series, vertical 8 39106800 Pot, Union Nut, face plate, wear ring assy. 4 39701200 Seal, shaft 9 39101200 Basket 5 39104600 Impeller,½ hp 10 39101900 O-ring 5 39153100 Impeller,
ملخص المحتوى في الصفحة رقم 13
SECTION XI. TECHNICAL DATA, (continued) C. DYNAMO PUMP 1 14 2 13 17 * 27 12 21 16 * 20 15 * 18 22 SNAP TAB 23 3 11 24, 24A SNAP TAB 4 19 25 5 26 6 MOTOR - SEE NOTE 1 9 SNAP TAB SLOT 8 9 10 7 Replacement Parts Find Part Description Find Part Description No. No. No. No. 6 35-3002 Impeller - 1½ hp Motors 6 35-4552 Impeller - ¾ hp 1 35-6471 ¾A std. 48 frame thru-blt 115 only 6 35-5122 Impeller 1, 1½ HP 1 35-6472 1A std. 48 frame thru-blt 115 only 7 35-4630 Housing, body 1 35-6469 1½A std. 48 fram
ملخص المحتوى في الصفحة رقم 14
SECTION XI. TECHNICAL DATA, (continued) B. DYNAMO PUMP, (continued) 1 14 2 13 17 * 27 12 21 16 * 20 15 * 18 22 SNAP TAB 23 3 11 24, 24A SNAP TAB 4 19 25 5 26 6 MOTOR - SEE NOTE 1 9 SNAP TAB SLOT 8 9 10 7 Replacement Parts Find Part Description No. No. 15-5118 25 ft. cord and plug 15-5370 25 ft. cord and plug, CSA approved 15-5234 3 ft. cord with twist lock plug 35-2245 Strain relief bushing for cords 15-5297 Photo sensor add-on 23 35-4650 Body - motor enclosure 24 35-4656 Cap - motor enclosur
ملخص المحتوى في الصفحة رقم 15
REV. F 5-1-01 15 P/N 99101100