ملخص المحتوى في الصفحة رقم 1
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Warning
Please read carefully before proceeding with installation. Your failure to follow a attached
instructions or operating parameters may lead to the product's failure and possible
damage to property.
*******************************************************************************************
Save manual for future reference.
Model FMRO4-ZW
ZERO WASTE REVERSE OSMOSIS SYSTEM
ملخص المحتوى في الصفحة رقم 2
Thank you for your purchase of a Flowmatic Reverse Osmosis system. With proper installation and maintenance, this system will provide you with high quality water for years to come. All of Flowmatic water enhancement products are rigorously tested by independent laboratories for safety and reliability. If you have any questions or concerns, please contact our customer service department at 1-800-461-4406 TABLE OF CONTENTS Operational Parameters ....................................................
ملخص المحتوى في الصفحة رقم 3
Operational Parameters Do not use with water that is microbiologically unsafe or of unknown quality, without adequate disinfection before or after the system. Operating Temperatures: Maximum 100°F (37.8°C) Minimum 40°F ( 4.4°C) Operating Pressure: Maximum 100 psi (7.43 g/cm2) Minimum 40 psi (2.80 kg/cm2) pH Parameters: Maximum 11 Minimum 3 Iron: Maximum 0.2 ppm TDS (Total Dissolved < 1000 ppm Solids): Turbidity: <5NTU Hardness: Recommended hardness not to exceed 7 grains per gallon, or 120ppm. S
ملخص المحتوى في الصفحة رقم 4
Installation of Faucet Caution: Porcelain sink surface material is extremely hard and may crack or chip. Use extreme caution when drilling. Watts accepts no responsibility for damage resulting from the installation of the faucet. Black Locating Washer (used where a 1/2" hole is available, reverse when mounting on stainless steel or when using drilled hole) Brass Insert (sleeve) 1 /4" Tub Plastic Sleeve 1 /4" Compression Nut Step 1 Determine desired location to drill a hole for the faucet on your
ملخص المحتوى في الصفحة رقم 5
Installation of hot and cold water supply line valves For 3/8” plumbing For 1/2” plumbing Hand tighten brass nuts then apply 1/4 turn with a wrench. To RO System 1/4" Compression Nut 1/4" Compression Nut Plastic Sleeve Brass Plastic Sleeve Insert Brass Insert 3/8"M X 1/2"F Adapter Angle Stop Valve Angle Stop Valve (not included) Rubber (not included) 1/2"M X 3/8"F X 1/4"Comp. Washer with needle valve RO Tubes will be connected on page 6. Step 6 Turn off the hot and cold water supply to the fauce
ملخص المحتوى في الصفحة رقم 6
Mounting the RO module Step 10 Determine the best location for the RO Module to be mounted and allow for future system maintenance. Use a Phillips screwdriver and secure the screws 5 3/4” apart and 16” from the bottom of the cabinet. Note: There will be (2) Blue, (1) Green and (1) Black coming from the module. Do not cut these tubes at this time. Connecting to the faucet Step 11 Connect blue tube from in-line filter over to the faucet shank. Place the brass nut onto the tube, followed by the pl
ملخص المحتوى في الصفحة رقم 7
Installation of Storage Tank Apply Teflon tape in a clockwise direction around the Step 15 male pipe threads on the tank. Thread the ball valve (supplied in the parts bag) onto the stainless steel connector on the tank. Note: Do not over tighten plastics connections. Step 17 Thread 1/4” plastic connector fitting (supplied in the parts bag) into the ball valve attached to the tank. Step 16 Connecting the Tank Step 18 Postion the tank in the desired location. Stand it upright or using black plast
ملخص المحتوى في الصفحة رقم 8
Start up Instructions Warning: To prevent the possibility of electrical shock, clean up any water on cabinet floor and dry all water from outside of RO unit. Turn on the incoming hot and cold water angle stop valves. Turn Step 1 on the water line needle valves by turning counter clockwise. Check the system for leaks and tighten fittings as necessary. Note: Check daily over the next week to ensure no leaks are present. Step 2 Plug the (24 volt) transformer power cord connector into the RO system
ملخص المحتوى في الصفحة رقم 9
Semi-annual maintenance continued Step 7 Inspect O-rings for wear and replace them if needed (order part no. WP113029 from Watts.) Lubricate O-rings with a water soluble lubricant such as KY Jelly®, (petroleum based lubricants such as Vaseline® must not be used.) Be sure to properly seat the O-ring in the housing before threading the housings onto the lid assembly. Note: Keeping the RO module in an upright position while re- attaching the housings will help ensure the o-ring stays properly seate
ملخص المحتوى في الصفحة رقم 10
Membrane Maintenance Membrane filters have a life expectancy of 2 to 5 years, depending on the incoming water conditions and the amount of use of the RO system. If at any time you notice a reduction in water production or a change in the taste of the RO water, it could be time to replace the membrane. Step 1 To change the membrane, use a 5/8" wrench to remove the nut from the cap side of the membrane housing (the end with only one elbow). Remove the cap from the white horizontal membrane housing
ملخص المحتوى في الصفحة رقم 11
Trouble shooting Problem Cause Solution Low/slow production Excessive air pressure in tank Relieve pressure at Schrader valve on tank (set to 7 psi with the tank empty) Wiring connection broken (plug 110 AC wall Pump not operating plug back in at wall and/or reconnect the 24 VAC wire harness connectors) Replace pump if needed Replace membrane Fouled membrane Replace filters Plugged pre-filters Check tubes to make sure they are not kinked Crimped tubing Ensure valves are opened by turning valve A
ملخص المحتوى في الصفحة رقم 12
Adjust Faucet If the faucet has developed a drip it can be corrected by following the steps outlined below. Step 1 Remove faucet Spout first. Position both thumbs on the back edge of the lever and push forward. Step 2 Lever will slide forward and completely off of the faucet base. Step 3 Small brass tee can be turned 1/2 turn, counterclockwise, to adjust the tension on the black lever. This adjustment may be necessary to stop slow drips from tip of faucet. You may need to repeat the process unti
ملخص المحتوى في الصفحة رقم 13
SERVICE RECORD SERIAL NO. DATE OF PURCHASE DATE OF INSTALL INSTALLED BY # / / / / NAME: Date of (6 mos.) (6 mos.) (1 yr.) (2-5 yrs.) OTHER Maintenance 1st stage 2nd stage Final Filter TFM Memb. Sediment Carbon Block Carbon NOTES: 13
ملخص المحتوى في الصفحة رقم 14
Limited Warranty What your Warranty Covers: Limited 3 year warrranty on the Reverse Osmosis module, tank and faucet if defective. 1 year warranty on the electrical components, pump, pressure switch, solenoid valve, and transformer if defective. No warranty on replaceable filters and membranes. Return unit after obtaining a return authorization (see below), less tank, within 3 year of original retail purchase, FLOWMATIC SYSTEMS will repair or, at FLOWMATIC ‘ S option, replace the system at no cha
ملخص المحتوى في الصفحة رقم 15
15
ملخص المحتوى في الصفحة رقم 16
21