ISSUE DATE REVISIONS 900.0394 1.0 February 2006 Initial Release 900.0800 1.0 June 2006 Correct power supply part # and voltage 1.01 June 2006 Correct RS232 wiring Rev. 1.01 ii 900.0800 19-Jun-06
ملخص المحتوى في الصفحة رقم 3
FCC COMPLIANCE STATEMENT INFORMATION TO THE USER: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmfu
ملخص المحتوى في الصفحة رقم 4
IMPORTANT SAFEGUARDS 1. READ INSTRUCTIONS – All safety and operating instructions should be read before the unit is operated. 2. RETAIN INSTRUCTIONS – The safety and operating instructions should be retained for future reference. 3. HEED WARNINGS – All warnings on the unit and in the operating instructions should be adhered to. 4. FOLLOW INSTRUCTIONS – All operating and use instructions should be followed. 5. CLEANING – Unplug the unit from the outlet before cleaning. Do not use liquid
ملخص المحتوى في الصفحة رقم 5
IMPORTANT SAFEGUARDS 14. POWER-CORD PROTECTION – Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords and plugs, convenience receptacles, and the point where they exit from the monitor. 15. OBJECT AND LIQUID ENTRY – Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short-out parts that could result in a fire or electric
ملخص المحتوى في الصفحة رقم 6
EXPLANATION OF GRAPHICAL SYMBOLS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instruction in the literature acco
ملخص المحتوى في الصفحة رقم 7
TABLE OF CONTENTS SECTION 1: INTRODUCTON ...................................................................................................................1 1.1 PRODUCT DESCRIPTION............................................................................................................ 1 1.2 FEATURES.................................................................................................................................... 1 1.3 ADDITIONAL INFORMATION...............................
ملخص المحتوى في الصفحة رقم 8
TABLE OF CONTENTS, CONTINUED 5.2.8 List VectorScan Contents .............................................................................................. 32 5.2.9 Program a Tour.............................................................................................................. 33 5.2.10 Run a Tour ..................................................................................................................... 33 5.2.11 Delete a Tour ............................................
ملخص المحتوى في الصفحة رقم 9
LIST OF FIGURES, CONTINUED Figure 6. HEGS5000 Icon Overlay................................................................................................................. 19 Figure 7. MUX Mode English Text Version .................................................................................................... 43 Figure 8. MUX Mode Icon Version................................................................................................................. 43 Figure 9: Ultrak Code Ser
ملخص المحتوى في الصفحة رقم 10
Notes: Rev. 1.01 x 900.0800 19-Jun-06
ملخص المحتوى في الصفحة رقم 11
SECTION 1: INTRODUCTON 1.1 PRODUCT DESCRIPTION The HEGS5000 is a controller designed to provide simple operation of the Honeywell KD6/HD6 series domes, VCRs, and multiplexers: 16 multiplexers, 16 VCRs and 256 domes can be controlled via the HEGS5000’s two serial ports. All functions of the individual units are supported remotely and intelligently. 1.2 FEATURES The HEGS5000 controller includes the following features: • Integrated control of Domes, VCRs, and Multiplexers. • Control of
ملخص المحتوى في الصفحة رقم 12
Notes: Rev. 1.01 2 900.0800 19-Jun-06
ملخص المحتوى في الصفحة رقم 13
SECTION 2: INSTALLATION AND EQUIPMENT SETUP 2.1 CONNECTIONS A terminal block is provided for connection between the HEGS5000 controller and peripheral equipment. A coiled cable is provided for connection between the HEGS5000 and the terminal block. Plug one end of the coiled cable into the connector on the back of the HEGS5000 and the other end into the jack on the terminal block. Description Power Supply Connect the power supply, part number 849193-0089, provided with the unit. CO
ملخص المحتوى في الصفحة رقم 14
2.2 INSTALLATION DIAGRAMS KX1610CN Multiplexer 2 - RX (data in) VCR 5 - Ground Cam 1 Input Input RS-232 Output Output 1 2 RX (Data In) 3 Spot Spot 4 Monitor 5 GND 6 7 8 9 DB9-Female Main Main Monitor Cam 16 2 - RX (data in) 5 - Ground RS-232 1 2 RX (Data In) 3 Part #849193-0089 4 5 PSU GND 6 12 VDC 7 2A RS-485 8 + - RS-232 9 GND DB9-Male R2 S 32 TX +12VDC RS-485 (D-) RS-485 (D+) GND RS-232 (RX) RS-232 (TX) RS-232 (RX) RS-232 (TX) RS-485 (D+) GND RS-485 (D-) +12VDC HEGS5000 System Controller
ملخص المحتوى في الصفحة رقم 15
2.2 INSTALLATION DIAGRAMS, CONTINUED 1 6 VCR 2 9 5 DB-9 Female rear view of connector KD6 / KD6Z 1 6 Dome -32 VCR 1 9 5 DB-9 Female rear view of connector 5 9 Multiplexer 2 KD6 / KD6Z 6 Dome - 1 1 DB-9 Male rear view of connector 5 9 Multiplexer 1 6 1 RS-485 (D-) +12VDC DB-9 Male rear view of connector GND RS-485 (D+) RS-232 (RX) RS-232 (TX) Figure 2: Connection Diagram 1 Rev. 1.01 5 900.0800 19-Jun-06
ملخص المحتوى في الصفحة رقم 16
2.2 INSTALLATION DIAGRAMS, CONTINUED 1 6 RS-232 To HEGS5000 to VCR 9 5 DB-9 Female rear view of connector RS-232 VCR cable connections 5 9 To HEGS5000 RS-232 to MUX 6 1 DB-9 Male rear view of connector RS-232 MUX cable connections Figure 3: Connection Diagram 2 Rev. 1.01 6 900.0800 19-Jun-06 +12VDC +12VDC RS-485 (D-) RS-485 (D-) RS-485 (D+) RS-485 (D+) GND GND RS-232 (RX) RS-232 (TX) RS-232 (RX) RS-232 (TX)
ملخص المحتوى في الصفحة رقم 17
2.3 EQUIPMENT SETUP 2.3.1 KD6/HD6 Setup The KD6/HD6 Dome must be set to Honeywell Diamond protocol. The address of the KD6/HD6 dome must be set to match the address set for that camera number in the HEGS5000. That is, the KD6/HD6 camera defined as camera 1 in the HEGS5000 system setup must be physically addressed 001 using the rotary switches on the KD6/HD6 receiver board. Refer to the KD6 or HD6 Series User Manual for switch settings and detailed operation. 2.3.2 Multiplexer Setup T
ملخص المحتوى في الصفحة رقم 18
Notes: Rev. 1.01 8 900.0800 19-Jun-06
ملخص المحتوى في الصفحة رقم 19
SECTION 3: MODES OF OPERATION 3.1 MODES OF OPERATION There are two modes of operation when using the HEGS5000 as a standalone controller: 1. HEGS5000 = Standalone = PTZ control (KD6/HD6 and KDZ series) only. Note: KDZ series domes have been discontinued. 2. HEGS5001 = MUX Mode = MUX/VCR control capability and PTZ control There is a third mode of operation that is only for use with the HSX3208L Matrix Video Switcher. 3. HEGS5002 = System = HSX3208L Switcher. Refer to the HSX3208L Swit
ملخص المحتوى في الصفحة رقم 20
3.2 MODE CONFIGURATION, CONTINUED 3. Press or keys to scroll through the available options. • Standalone (control KD6/HD6 PTZs only) • Mux Mode (control multiplexers, VCRs, and KD6/HD6 PTZs) • System Mode (must be used with HSX3208L switcher) • Stdalone/Mux Fw. (upload new firmware to the HEGS5000). Refer to Section 7 for uploading the latest firmware. • System Firmware (upload new firmware to the HEGS5000 system controller). Refer to the HSX3208L User Manual to upload the latest fi