ملخص المحتوى في الصفحة رقم 1
I N S T A L L A T I O N
I N S T R U C T I O N S
CARE AND USE MANUAL FOR:
CLASSICAL ISLAND RANGE HOODS
Models covered by these instructions:
SIU3, SIU4, SIU5, SIU8,
* * * B E F O R E I N S T A L L A T I O N * * *
ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED
DURING SHIPPING
* * * S H I P P I N G D A M A G E * * *
MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT
Telephone (Toll Free): 866.528.4987 Fax (Toll Free): 866.365.9204
www.siriush
ملخص المحتوى في الصفحة رقم 2
W A R N I N G S Thank you for purchasing a Sirius Range Hood. Please read all the instructions in this manual before installing the appliance. Save these instructions for future reference. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure they do not play with the appliance. If the range hood is vented, the air so vented must be ducted into a dedicated duct that is not showed with any other
ملخص المحتوى في الصفحة رقم 3
TABLE OF CONTENTS BEFORE YOU BEGIN 1 MINIMUM AND MAXIMUMS 1 DUCTING 1 Duct Run Calculation 2 ELECTRICAL 2 Electrical Supply 2 INSTALLATION 2 Structural preparation for the hood fan 2 installation Fixing the Main Support Bracket 3 Attaching the range hood to the ceiling 4 Connecting Electricity and Ducting 4 Re-Circulating Requirements 4 Schematic of Classical Island Components 5 OPERATING PROCEDURES 6 General Advice 6 Functions 6 MAINTENANCE 7 Cleaning the Filter 7 Cleaning the Hood 7 Light Bu
ملخص المحتوى في الصفحة رقم 4
B E F O R E Y O U B E G I N The manufacturer declines all BEFORE STARTING – please read responsibility in the event of failure this entire document and ensure you to observe the instructions given are fully conversant with the require- here for installation, maintenance ments and limitations. These units and suitable operation of the weigh approximately 125lbs and product. The manufacturer further therefore require a minimum of two declines all responsibility for injury peo
ملخص المحتوى في الصفحة رقم 5
heaters. To minimize the risk of based on the table below. drawing these lethal gases back into Maximum Run the home, please follow the heating 6” or 3 1/4 x 10” duct 100 FT equipment manufacturers safety Deduct standards and guidelines. Refer to NFPA and ASHRAE for additional Each 90 elbow used 15FT information. Each 45 elbow used 9FT Each 6” or 3 1/4 x 10” duct Duct Run Calculation Transition used 1FT The maximum duct run before Each 3’1/4 x 10” to 6” effecting the performance of
ملخص المحتوى في الصفحة رقم 6
and ideally not higher than 32”above the frame by screwing through the the cook-top. It is strongly ceiling into the heavy members recommended, at this point, that inside the ceiling. This is critically calculations and measurements be important as the entire hood fan made and all planning and heights hangs from this position, and be finalized. You will need to fit the ceiling board alone will not appropriate length of ducting to the support the weight
ملخص المحتوى في الصفحة رقم 7
items “B” on the schematic on page. machine screws at point “E” on the 5. schematic on page 5 – THIS MUST BE DONE IMMEDIATELY AND Check that the plastic flaps at the SHOULD NOT BE SKIPPED. exhaust outlet for the fan move freely and have not become jammed Ensure the entire structure is sturdy during shipping or whilst working - serious injury, death and MAJOR with the power unit. Connect an damage could result should the unit appropriate length of ducting to the not be well connect
ملخص المحتوى في الصفحة رقم 8
The deflector connects to the top of through the grills on the side of the Bracket “A” and forces the air out chimney section back into the room. SCHEMATIC OF MODULAR ISLAND COMPONENTS 5
ملخص المحتوى في الصفحة رقم 9
O P E R A T I N G P R O C E D U R E S Never pick up a flaming pan – you Read all the instructions before may be burned. DO NOT USE operating the appliance. WATER including wet dishcloths or Save these instructions for future towels, as a violent steam explosion reference. may occur. General Advice Functions Ensure that the grease filters are in Classical Island Range Hood – place. Without these components, Mechanical push buttons: operating blowers could catch on to A: Lig
ملخص المحتوى في الصفحة رقم 10
M A I N T E N A N C E On the surfaces that are exposed The hood-fan should provide many directly to heat from the cook-top, it years of trouble free service is advisable to clean these on a provided it is maintained properly. regular basis, to avoid the marks from becoming baked on. Cleaning the Filter Do not under any circumstances use Clean the grease filter either by an abrasive type cleaner as this will carefully hand washing (so as not to scratch and damage the stainles
ملخص المحتوى في الصفحة رقم 11
T h r e e Y e a r L i m i t e d W a r r a n t y WARRANTY SERVICE To qualify for warranty service, you must notify Sirius Range Hoods at the address stated below or call toll free USA or Canada 1-866-528-4987 and provide the model number, description of the fault or defect and original date of purchase. Sirius reserves the right to request proof of original purchase. Sirius will at its sole option and discretion replace products that arrive damaged through shipping, provided shipping
ملخص المحتوى في الصفحة رقم 12
USA: CANADA: SIRIUS RANGE HOODS (USA) LTD. SIRIUS RANGE HOODS LTD. 1051 Clinton Street 1252 Speers Road Unit 11 Buffalo, NY 14206 Oakville, ON L6L 5N9 Telephone (Toll Free): 866.528.4987 Telephone: 905.257.0046 Fax (Toll Free): 866.365.9204 Fax: 905.847.0330 www.siriushoods.com Email: info@siriushoods.com