ملخص المحتوى في الصفحة رقم 1
™
36" (91.4 cm) PRO-LINE SERIES ISLAND RANGE HOOD
Installation Instructions and Use and Care Guide
™
HOTTE D'ASPIRATION PRO-LINE DE 36" (91,4 cm)
POUR CUISINE CONFIGURÉE EN ÎLOT
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION RÉSI
ملخص المحتوى في الصفحة رقم 2
TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 SÉCURITÉ DE LA HOTTE DE CUISINIÈRE . . . . . . . . . . . . . .16 INSTALLATION REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . .4 EXIGENCES D'INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . .18 Outillage et pièces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Tools and Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 3
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave the surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON w
ملخص المحتوى في الصفحة رقم 4
INSTALLATION REQUIREMENTS Product Dimensions Tools and Parts Gather the required tools and parts before starting installation. Read and follow the safety instructions provided with any tools 12¹⁄₁₆" 13³⁄₄" listed here. (30.6 cm) (34.9 cm) Tools needed: ■ level ■ drill with 1¹⁄₄" (3.0 cm) drill bit ■ pilot hole drill bit (determined by chimney support attachment method) ■ pencil 26³⁄₈" (65.1 cm) ■ wire stripper or utility knife min. ■ measuring tape or ruler 39" (99.1cm) ■ pliers max. 23⁵⁄₈"
ملخص المحتوى في الصفحة رقم 5
Cold weather installations An additional backdraft damper should be installed to minimize Installation Clearances backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house. Make-up air Local building codes may require the use of make-up air systems when usi
ملخص المحتوى في الصفحة رقم 6
Calculating Vent System Length Electrical Requirements To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. WARNING Maximum equivalent vent length is 35 feet (10.7 meters). Vent piece 6" (15.2 cm) round 45° elbow 2.5 feet (0.8 m) Electrical Shock Hazard 90° elbow 5.0 feet Disconnect power before servicing. (1.5 m) Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. wall cap 90
ملخص المحتوى في الصفحة رقم 7
INSTALLATION INSTRUCTIONS 7. Tape the template (supplied in the chimney support carton) to Install Chimney Support the ceiling and mark the mounting holes, electrical hole and vent location (if used) on the ceiling. Because of the size and weight of this island hood, the chimney support must be securely attached to the ceiling. A ■ For plaster or drywall ceilings, the chimney support must be attached to joists. If this is not possible, you must build a B support structure behind the plaster or d
ملخص المحتوى في الصفحة رقم 8
3. Attach the extension to the support using the 4 bolts supplied 9. Replace the four screws and tighten securely. with the extension kit. Tighten bolts securely. Make Electrical Connection A WARNING D C B Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. A. Chimney extension frame Failure to do so can result in death or electrical shock. B. Chimney support C. Bolt D. Captive threaded insert 1. Disconnect power. 2. Use twist-on connectors
ملخص المحتوى في الصفحة رقم 9
4. Install the two vent extension pieces onto the diverter, pushing them until they stop. Install Chimney Covers A A Vented Installation Option 1. Attach the vent system to the damper. Seal all joints with duct tape. 2. Remove the plastic covering from the chimney covers. A. Vent extensions 3. Slide the upper chimney cover over the chimney support and attach to the top of the support using two screws provided. 5. Discard the lower chimney cover shipped with the hood and use the cover from the R
ملخص المحتوى في الصفحة رقم 10
3. Slide the chimney cover provided with the extension kit over 2. From the underside of the hood, plug control cables together the lower chimney support and extension frame and secure to as shown. the top of the extension frame using the two screws provided. A 3. Insert each connected cable into a black plastic connector box half. B 4. Place the top half of the connector box on each and screw the two halves together using the four screws provided for each connector box. A C B A A. Screw B B. Up
ملخص المحتوى في الصفحة رقم 11
2. Install grease filters using two hands by first pulling and turning the knob to the left so that the locking lever does not RANGE HOOD USE protrude from the filter. 3. Insert the opposite end of the filter into the retaining channel. Operation 4. Insert knob end and turn knob to the right to lock the filter into place. The hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes a
ملخص المحتوى في الصفحة رقم 12
Replacing a halogen lamp This hood uses four 12-volt, 20 watt halogen lamps. RANGE HOOD CARE Turn off the range hood and allow the halogen lamps to cool. Replace bulb using a tissue to handle bulb, or wearing cotton Cleaning and Maintenance gloves. Do not touch bulb with bare fingers. Be sure lights are cool before cleaning the hood. 1. Disconnect power. Exterior surfaces 2. Remove 2 screws from the circular metal trim around the ■ Do not use steel wool or soap-filled scouring pads. lamp assemb
ملخص المحتوى في الصفحة رقم 13
REQUESTING ASSISTANCE OR SERVICE If you need assistance or service in U.S.A. If you need assistance or service in Canada Call the KitchenAid Customer Interaction Center toll-free at For product related questions, please call the KitchenAid Canada 1-800-253-1301. Our consultants are available to assist you. Inc. Customer Interaction Center toll free: 1-800-461-5681 Monday to Friday 8:00 a.m. – 6:00 p.m. (EST). When calling: Please know the purchase date, and the complete Saturday 8:30 a.m. – 4:30
ملخص المحتوى في الصفحة رقم 14
® KITCHENAID VENTILATION WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid or KitchenAid Canada (hereafter ì KitchenAid”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company. ITEMS KITCHENAID WILL NOT PAY FOR 1. Service ca
ملخص المحتوى في الصفحة رقم 15
WIRING DIAGRAM 15
ملخص المحتوى في الصفحة رقم 16
SÉCURITÉ DE LA HOTTE DE CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte
ملخص المحتوى في الصفحة رقم 17
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla
ملخص المحتوى في الصفحة رقم 18
EXIGENCES D'INSTALLATION La hotte d'extraction a été configurée à l'usine pour la décharge à travers le toit ou à travers le mur. Pour une installation avec Outillage et pièces recyclage, voir “Installation avec recyclage, à la section Rassembler les outils et pièces nécessaires avant de commencer “Installation du cache-cheminée”. l'installation. Lire et suivre les instructions fournies avec les outils indiqués ici. On devra assurer l'étanchéité de toutes les ouvertures (plafond et mur) découp
ملخص المحتوى في الصفحة رقم 19
■ Ne pas connecter ensemble deux raccords coudés. Dégagements de séparation à respecter ■ Assurer l'étanchéité de chaque jointure du circuit d'évacuation avec du ruban adhésif pour conduit. ■ Utiliser un calfeutrant pour assurer l'étanchéité autour de la bouche de décharge à l'extérieur, entre le conduit et l'ouverture à travers le toit ou le mur. Installation dans une région à climat froid Il convient d'installer un clapet anti-reflux additionnel pour minimiser les reflux d'air froid, et d'inst
ملخص المحتوى في الصفحة رقم 20
Calcul de la longueur effective du circuit Spécifications électriques d'évacuation Pour calculer la longueur effective du circuit d'évacuation AVERTISSEMENT nécessaire, ajouter les longueurs équivalentes (pieds/mètres) de tous les composants utilisés dans le système. La longueur équivalente du circuit ne doit pas dépasser 35 pieds (10,7 mètres). Composant du circuit Conduit rond dia. 6" (15,2 cm) Risque de choc électrique Coude à 45° 2.5 pi Déconnecter la source de courant électrique avant (0,