ملخص المحتوى في الصفحة رقم 1
Owner's Manual
Manual del Propietario
®
SLIDER/CASEMENT AIR CONDITIONER
HORIZONTAL/MARCO ACONDICIONADOR DEAIRE
Model, Modelo 580. 75063 580.75123
Distributed by Sears, Roebuck and Co., Hoffman Estates, IL 60179
www.sears.com
ملخص المحتوى في الصفحة رقم 2
TABLE OF CONTENTS ........................2 Capacity and Running Time ..................... 9 Features ................................................. 10 WARRANTY ..............................................2 Using the Air Conditioner ....................... 10 SAFETY .....................................................3 Display ................................................... 11 Important Safety Instructions ...................... 3 Air Direction Adjustment ......................... 1I
ملخص المحتوى في الصفحة رقم 3
IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER. FOR YOUR SAFETY _ Avoid fire hazard or electric shock. Do not store or use gasoline or other flammabIe Do not use an extension cord or an adapter plug. vapors and liquids in the vicinity of this or any other Do not remove any prong from the power cord. appliance. Read product labels for flammability and other warnings. PR
ملخص المحتوى في الصفحة رقم 4
OBSERVE ALL LOCAL CODESAND ORDINANCES. RECOMMENDEDGROUNDINGMETHOD DO NOT,UNDERANY CIRCUMSTANCES,REMOVE Foryourpersonalsafety,thisappliancemustbegrounded. THE POWERSUPPLY CORD GROUNDPRONG. Thisappliancehasa powersupplycordwitha 3-prong ELECTRICAL GROUNDIS REQUIREDON THIS groundingplug.To minimizepossibleshockhazard,the APPLIANCE. cordmustbepluggedintoa matinggroundingtypewall For 230/208volt 60 Hz, AC only, 15Afusedand receptacle andgroundedinaccordance withthe National properlygroundedelectrical
ملخص المحتوى في الصفحة رقم 5
ELECTRICAL SERVICE INSTALLATION REQUIREMENTS Check your available electrical service. The power These instructions are for a horizontal sliding or a supply available must be the same as that shown casement window. The electricaI outlet must be on the unit nameplate (found on right side of cabinet). within reach of the power cord. AiI models are equipped with a 3-prong service plug to provide proper service and safe positive Side louvers and the rear of the air conditioner must grounding. Do not
ملخص المحتوى في الصفحة رقم 6
INSTALLATION HARDWARE INSTALLATION Pick a location that will allow the air conditioner to bIow the cold air into the area you want. Windows used for installation must be strong enough to support the weight of the air conditioner. Good installation with speciaI attention to the proper position of the unit will lessen the chance that service will be needed. When cooling more than one room, installation location is very important. To cool your rooms, cold air must be blown from the air conditioner
ملخص المحتوى في الصفحة رقم 7
_lput the Support Bracket against the outside H Measure height of window opening from top of wall and tighten the BoIts on top of the Bracket. Bracket assembly as shown Fig. 5. Subtract 20-3/4 inches. Mark this measurement on Curtain and cut Adjust the Leveling Bolt so that the air conditioner will be installed with a very slight tilt (about 1/4") the Curtain. (Fig. 5) downward toward the outside for proper drainage. Tighten the nut. (Fig. 3) NOTE: DO NOT drill a hole in the bottom of the base p
ملخص المحتوى في الصفحة رقم 8
_1_ Place Air Conditioner in window opening. It CASEMENT WINDOW should sit on Bracket assembly so that Curtain INSTALLATION Frame and cabinet Side Guides are against top and side window jambs. Mate front of Bracket with Base • Installation procedure [sthe same as that described m Guide attached to the bottom of base pan. steps 1 through I1 and step 13 of the Hobzenta_Sliding Window installation _i] Drill 1/8 inch holes in window track through the • If the window opening is wider than 15-3/4 inch
ملخص المحتوى في الصفحة رقم 9
HOW AND WHY Your room air conditioner provides the following ....Compressor functions to make hot weather living more The modern high efficiency comfortable: compressor may have a high •Cools and circulates room air. pitched hum or pulsating • Lowers humidity by removing excess moisture. I noise that cycles on and off. • Filters out summertime dust, dirt, and some Unit Vibration ........................... airborne impurities. -Fan The unit may vibrate You may hear air and make noise The air con
ملخص المحتوى في الصفحة رقم 10
FEATURES USING THE AIR CONDITIONER To reduce the risk of fire, electric shock, or injury to persons, read the important SAFETY instructions section before operating this appliance. To begin operating the air conditioner after installation, follow these steps: 1. Plug in the air conditioner. (To prevent electrical hazards, do not use an extension cord or an adapter plug.) 2. Set the exhaust vent to the CLOSE position. 3. Set the TEMP Control to the coolest setting. 4 4. Set the MODE control at th
ملخص المحتوى في الصفحة رقم 11
DISPLAY POWER j- MODE • To turn the air conditioner ON, push this button. To - Every time you push this button, itwill shift among turn the air conditioner OFF, push the button again, COOL, ENERGY SAVER and FAN • This button takes priority over any other buttons, - ENERGY SAVER • When you first turn it on, the unit is in cool mode, • The fan stops when the compressor stops cooling, High fan speed, Temperature setting at 72°F Approximately every 3 minutes the fan will turn on and the unitwilt che
ملخص المحتوى في الصفحة رقم 12
5, TIMER REMOTE CONTROL - SHUT-OFF TIME Note: The Remote Control wilI not operate properly if • You will usually use shut-off time while you sleep. strong light shines on the sensor window of the Air • With unit running, use Timer to set number of hours Conditioner or if there are obstacles between the Remote untiI shut-off. Control and the Air Conditioner. • Foryour steeping comfort, once Time is set, the Every time you push button, you will hear beep sound Temperature setting will raise 2F aft
ملخص المحتوى في الصفحة رقم 13
AIR FILTER CLEANING The Air Filter will become dirty as it removes dust from the inside air. It should be washed at least every 2 weeks, If the Air Filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced, possibly damaging the unit, •PulI the inlet grille forward, grasping both tabs, FIG. 20 then pull out the air filter. (FIG. 18) • Wash the Air Filter under the faucet with warm water, Be sure to shake off all the water before HOWTOREMOVETHE FRONTGRILLE r
ملخص المحتوى في الصفحة رقم 14
BEFORE CALLING FOR SERVICE Check the following list to be sure a service calI is reaIly necessary. A quick reference to this manual may help you avoid an unneeded service call. THE AIR CONDITIONER WILL NOT OPERATE Check if.., Then.,. The Current interrupterdevice is tdped. Press the RESET button locatedon the power cord plug Ifthe RESETbutton will not stay engaged,discontinue useof the air conditionerand contact a quaIifiedservicetechnician. Wall plugdisconnected. Pushplugfirmlyintowalloutlet. H
ملخص المحتوى في الصفحة رقم 15
-15-
ملخص المحتوى في الصفحة رقم 16
INDICE DE MATERIAS ............................. 16 OPERACION .............................................. 23 C6mo y por que ..................................... 23 GARANTJA ................................................ 16 Sonidos normales .................................. 23 Capacidad y tiempo de funcionamiente .--23 SEGURIDAD .............................................. 17 Caracteristicas ..................................... 24 Uso del equipo de aire acondicionado --24 Importantes in
ملخص المحتوى في الصفحة رقم 17
IMPORTANTES INSTRUCCIONES DE SEGURIDAD Las siguientes instrucciones de seguridad le indicaran c6mo usar su equipo de aire acondicionado de habitacion para evitar dafios para usted mismo y para su EQUIPO DE AIRE ACONDICIONADO. / POR SU SEGURIDAD _ Evite lospeIigrosde incendiosY No aImacene ni use gasolina u otros vapores y descargaset6ctbcas.No useuncable deextensi6nni un liquidos inflamables cerca de este o cualquier otro electrodomestico. Lea Ias etiquetas de los enchufeadaptador.No eliminening
ملخص المحتوى في الصفحة رقم 18
RESPETE TODOS LOS CODIGOS YREGLAMENTOS.METODO RECOMENDADO DE CONEXION A TIERRA Persupropia seguddad este aparato debe conectarse atiena. Este BAJO NINGUNA CIRCUNSTANCIA CORTE, QUITE 0 aparate viene equ_pado sonuncable dealimentacbn y una slavija de EVITE ELUSO DE LACONEXlON ATERRA DE ESTA tresterminales. Para reducir almaximo elpeligro dechoque electece, CLAVlJA. elcable debe estar conectado aunaconexbn depared conconexi6n ESTE APARATO NECESlTA SER CONECTADO ATERRA. atieITa y esta conexi6n debe
ملخص المحتوى في الصفحة رقم 19
SERVICIO ELECTRICO REQUISTIOS DE VENTANA Compruebe cual es ta atimentaci6n electrica que tlega a Estas instrucciones son para una ventana de su domicilio La alimentacion electrica disponibIe debe ser corredera horizontal o un marco de ventana. la misma que se muestra en la placa del fabricante de la unidad (que se halla en et lado derecho del gabinete de La salida etectrica debe quedar al alcance det cable corriente alterna). de conexi6n. Todos los modelos estan equipados con un enchufe de Para
ملخص المحتوى في الصفحة رقم 20
INSTALACION PIEZAS DE INSTALACION Escoja un lugar que le permita Ilevar el aire frio al area MONTAJE que desea. Las ventanas que se usen para la instaiaci6n deben tener la resistencia suficiente para soportar el peso del equipo de aire acondicionado. Una buena instalaci6n con atenci6n especial a la correcta posici6n de la unidad disminuir& ta probabilidad de que sea necesario efectuar reparaciones. Cuando se desea enfriar mas de una habitaci6n, la instalaci6n es muy importante puesto que el aire