ملخص المحتوى في الصفحة رقم 1
Portable Air Conditioner
OWNER’S MANUAL OWNER’S MANUAL
Read these instructions before use
Model: MM14CHCS
Voltage rating: 115V~60Hz
Power rating : 1400W
Customer Support : 1-800-474-2147
For product inquiries or support : www.honeywellportableac.com Made in China
ملخص المحتوى في الصفحة رقم 2
INDEX Read all instructions carefully before setting up and operating the unit. Keep this instruction manual for future reference. This manual is designed to provide important information needed to setup, operate, maintain and troubleshoot your portable air conditioner. Failure to follow these instructions may void the warranty. SECTION PAGE 1. INDEX .............................................................................................................. 1 2. THANK YOU......................
ملخص المحتوى في الصفحة رقم 3
THANK YOU Congratulations on your purchase of this versatile Honeywell Portable Air Conditioner. r. Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while a flexible air outlet hose sends heat outside. The air conditioner includes a window venting kit. No permanent installation is needed. The unit is easy to move from room to room and offers a truly flexible air
ملخص المحتوى في الصفحة رقم 4
USER TIPS To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier. If the product is being used with the fan function only, an open window could improve air circulation. Cooling and Dehumidifying Operation Fan Operation Important : Before installing the unit, place it UPRIGHT for 20 minutes before use to allow the refrigerant to stabilize. • Follow installation instructions to set up the unit. • Plug the unit into a pro
ملخص المحتوى في الصفحة رقم 5
SAFETY READ AND SAVE THESE INSTRUCTIONS Improper handling can cause serious damage to the appliance. WARNING 1. DO NOT operate the unit with a damaged plug or loose wall outlet. If the power cord is damaged, it must be replaced by the manufacturer or an authorized service agent. 2. DO NOT cover the air intake and exhaust when in use. 3. This appliance is not intended for use by children. Children should be supervised and should not play on or around the appliance. 4. DO NOT place objects on or
ملخص المحتوى في الصفحة رقم 6
SAFETY 8. DO NOT run the power cord under carpeting and rugs. 9. Use caution to prevent tripping on cord. 10. DO NOT use in areas where gasoline, paint or other flammable goods are stored. 11. Basic safety precautions should always be followed when using electrical appliances. 5
ملخص المحتوى في الصفحة رقم 7
PARTS DESCRIPTION 6 7 2 1 3 10 5 11 8 9 4 1. Control Panel (Incl. Signal Receptor) 7. Back Grill 2. Air Outlet 8. Lower Drain Plug 3. Handle 9. Power Supply Cord 4. Casters 10. Exhaust Hose Connector 5. Upper Drain Plug 11. Remote Control 6. Air Filter Installation Kit : 4 1 2 3 1. Window Bracket Kit............................. 1 Set x 1 x 1 x 2 2. Window Bracket Panel Adapter.......... 1 Piece 3. Plastic Pin........................................... 2 Pieces x 1 4. Hose Connector
ملخص المحتوى في الصفحة رقم 8
INSTALLATION 1 Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper fit on both ends. = 2 Adjust the window bracket as per width or height of your window and insert the plastic pins to fix at the desired position. Note : Do not install the window bracket to your window. This step is Plastic Pin required only to adjust it to the size of your window. The bracket should be removed from the window after the size is adjusted. Plastic Pin 3 Connect
ملخص المحتوى في الصفحة رقم 9
INSTALLATION 4 Connect the window bracket to the opposite end of the plastic hose. Ensure that all connections are tight and installed properly. 5 Connect the window bracket to the window. 6 The Portable Air Conditioner is now ready to use. 8
ملخص المحتوى في الصفحة رقم 10
INSTALLATION Note: 1. The supplied exhaust hose can be extended from 12 inches (1 foot) to 47 inches (3.9 feet). 2. Do not bend (to the extent shown below) the exhaust hose. A bent hose will block exhaust air and cause the unit to malfunction or shut-off. 20” NOT RECOMMENDED RECOMMENDED Warning: • The length of the exhaust hose is determined by the product specifications. Do not replace or lengthen it as this could cause the unit to malfunction. • Make sure the back of the unit is at least 20 i
ملخص المحتوى في الصفحة رقم 11
USE & OPERATION Warning Light Touch Screen Control Panel (when flashing) STOP Power Control Timer Control Mode Control Fan Speed Control Timer / Temperature Set Controls Power Control Fan Speed Control The Power Control turns the unit on and off. 3 settings: High, Medium and Low. Mode Control Timer Control Auto turn off: 3 settings: Cool, Dehumidify and Fan With machine in running mode, press timer button to select the A light will indicate which setting is currently being used. number of hours
ملخص المحتوى في الصفحة رقم 12
USE & OPERATION Remote Control The functions work the same as the portable air conditioner’s touch controls. All key functions can be accessed from the remote control. Temperature / Timer Set Control • Used for adjusting the timer and temperature. • The default display is room temperature. • When “ “ or “ “ key is Power Control pressed in cool mode, the set ON / OFF temperature is displayed and may be adjusted. After 10 seconds the display will revert Fan Speed Control back
ملخص المحتوى في الصفحة رقم 13
USE & OPERATION Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with ‘‘+’’ and ‘‘-’’ pointing in the proper direction. Caution • Use only two AAA or IEC R03 1.5V batteries. • Remove the batteries if the remote control is not in use for a month or longer. • All batteries should be replaced at the same time, do not mix with old batteries. • Properly dispose of used batteries. 12
ملخص المحتوى في الصفحة رقم 14
CLEANING & MAINTENANCE Appliance Maintenance: 1. Turn off the appliance before disconnecting the power supply. 2. Always clean the appliance with a soft dry cloth. Air Filter Maintenance: The air filter should be cleaned every two weeks. Clean it as follows: 1. Turn off the appliance and remove the air filter. (refer to page 5, #6) 2. Rinse it in lukewarm water. After cleaning, dry in a shaded and cool place, then reinstall. Maintenance After Use: 1. If the appliance will not be used for a long
ملخص المحتوى في الصفحة رقم 15
WATER CONDENSATION DRAINAGE Water Condensation Drainage When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (refer to page 10). This warning light indicates that the water condensation needs to be drained using the following procedures: Manual Draining Water may need to be drained in high humidity areas 1. Unplug the unit from power source. 2. Place a shallow pan under the lower drain plug. See diagram. 3. Remove the lower drain
ملخص المحتوى في الصفحة رقم 16
TROUBLESHOOTING GUIDE The following troubleshooting guide addresses the most common problems. If problems persist, call customer service. Unplug and disconnect the appliance from the power source before attempting to troubleshoot. Problem Possible Cause Solution • No electricity. • Check for power. • Batteries in the remote control need • Change remote control batteries. to be replaced. The air conditioning • The power cord is not properly • Remove and reconnect the power unit does not start
ملخص المحتوى في الصفحة رقم 17
TECHNICAL SPECIFICATIONS Description of Product Portable Air Conditioner Model MM14CHCS Voltage/Frequency 115 V~ 60 Hz Power (Cooling) 1400W Power (Heating) 1350W Cooling capacity 14000 BTU Heating capacity 12000 BTU Dehumidifying capacity 95 pints/24 hours Refrigerant Type R-410A Timer 24 hour (ON / OFF) Dimensions (W) x (D) x (H) (mm) 19.9 X 15.8 X 34 inches Weight (Kg) 92.6 lbs Electrical products should be properly disposed. Please recycle where facilities exist. Check with your local aut
ملخص المحتوى في الصفحة رقم 18
SERVICE AND WARRANTY 5-YEAR LIMITED WARRANTY 1st year parts and labor. 5 years on all parts of the sealed system, consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing. A. This warranty does not apply to any damage resulting from abusive, unreasonable use or damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. JMA NORTH AMERICA LLC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES
ملخص المحتوى في الصفحة رقم 19
SERVICE AND WARRANTY D. Please read the Instruction Manual carefully before setting up or using this product. If you believe this product to be suffering from a manufacturing fault, or if you have inquiries about this product, please contact our Customer Support: CUSTOMER SUPPORT JMA North America LLC Ramsey, New Jersey 07446 Phone: 800-474-2147 Email: info@jmana.us When contacting our Customer Support, please have the information below along with the proof of purchase. All warranty requests mus
ملخص المحتوى في الصفحة رقم 20
MM14CHCS_IM_Eng_USA_2 MM14CHCS_IM_Eng_Spa_USA_2 January 2013 January 2013 © 2013 AirTek Int’l Corp. Ltd. © 2013 AirTek Int’l Corp. Ltd. (JMATEK Int’l Group of Companies) (JMATEK Int’l Group of Companies) JMA North America LLC The Honeywell Trademark is used under license from The Honeywell Trademark is used under license from Ramsey, New Jersey 07446 Honeywell International Inc. Honeywell International Inc. Honeywell International Inc. makes no representation or Honeywell International Inc. mak