ملخص المحتوى في الصفحة رقم 1
TORNADO INDUSTRIES
7401 W. LAWRENCE AVENUE
CHICAGO, IL 60706
(708) 867-5100 FAX (708) 867-6968
www.tornadovac.com
Tornado
Operation & Maintenance Manual
For Commercial Use Only
Marathon 2000 Forward Only Extractor
CATALOG NO.
98190 (115V, 60 HZ)
For parts list see L8190GHP
Effective 12/19/2005
L8190GH Revised 12/05 2006 Tornado Industries All rights reserved.
ملخص المحتوى في الصفحة رقم 2
NOTES 2
ملخص المحتوى في الصفحة رقم 3
Write your machine’s serial number here:_________________________________ This illustrated instruction book covers: CATALOG NO. 98190 SERIES H SIZE 22” CAPACITY 20 Gal. VOLTS 115V AMPS 15 All specifications are subject to change without notice. TABLE OF CONTENTS: Warranty 4 Safety Instructions 5 Preparation & General Precautions 6 Cleaning Tips 9 Machine Specifications 11 Operation Instructions 12 Maintenance Issues 14 Troubleshooting Table 16 3
ملخص المحتوى في الصفحة رقم 4
Thank you for choosing Tornado products. We are proud to offer the most complete line of commercial and industrial cleaning equipment in the industry. Our reputation for quality, innovation and durability is unsurpassed. st * Effective January 1 , 2005. Terms subject to change without notice. 1) Windshear™ Blower-Dryer, Insulation Blowers, T191, T201, T12/1, CV 30, CV 38, CW 50, CW 100, Pro PAC Vacs, Duo-Upright Carpetkeepers™, and all chargers are warranted for 1 (one) year for both par
ملخص المحتوى في الصفحة رقم 5
IMPORTANT SAFETY INSTRUCTIONS FOR COMMERCIAL USE WHEN USING AN ELECTRICAL APPLIANCE, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY: 1. Do not leave machine when plugged in. Unplug from outlet when not in use and before servicing. 2. Use indoors only. Do not use outdoors and do not expose to rain. 3. Do not allow to be used as a toy. Close att
ملخص المحتوى في الصفحة رقم 6
SAVE THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this manual on file and handy. This machine will assure years of satisfactory service if operated and maintained according to recommendations in the manual. If additional information is needed, please contact your local distributor or call: TORNADO INDUSTRIES, INC. 7401 W.
ملخص المحتوى في الصفحة رقم 7
GENERAL PRECAUTIONS Make sure the machine is plugged into an electrical outlet with the same voltage and frequency rating as shown on the nameplate of the machine. Do not attempt to plug a 115-volt machine in a 230-volt outlet. Disconnect power cord from the outlet before attempting maintenance or repair work. Do not leave machine connected to an electrical outlet when unattended. Don’t abuse power cord. Never pull the machine by the cord or yank plug from the receptacle. If this machi
ملخص المحتوى في الصفحة رقم 8
ELECTRICAL This machine operates on a standard, 15 AMP, 115 volt AC circuit and has a grounded plug.* Make sure the machine is connected to an outlet having the same configuration as the plug. No ungrounded adapter should be used with this machine. *Special voltage models available. GROUNDING INSTRUCTIONS This machine must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk electric shock. This machine is e
ملخص المحتوى في الصفحة رقم 9
Sketch A Sketch B Sketch C STRAIN RELIEF Attaching the strain relief/cord retainer to the 50’ power cord. 1. Make a loop in power cord approximately 12” from receptacle end. 2. Slide cord loop through slot in retainer and over retainer arm. Pull slack cord back through slot to secure. Attach retainer to handle. EXTENSION CORD If an extension cord is used, the wire
ملخص المحتوى في الصفحة رقم 10
CLEANING TIPS Check the condition of the carpeting. If the carpet is loose, heavily soiled, stained, spotted or badly worn, point this out to the person in charge. Locate an inconspicuous spot on the area to be cleaned. Test carpet for colorfastness before proceeding. Pour the concentrated cleaning solution on the spot, cover with a white towel and place a heavy object on top to absorb the cleaning solution. Wait 10 minutes for any reaction to take place. Remove weight. If there is no c
ملخص المحتوى في الصفحة رقم 11
MACHINE SPECIFICATIONS ELECTRICAL: 115 V, 15 A, 60 HZ. DURABLE EXTENSION CORD: 75’ DRIVE SYSTEM: TRANSAXLE W/ VARIABLE SPEED, (0-100 FT/MIN) VACUUM MOTOR: 3 STAGE, 1 HP., 120 CFM VACUUM SHOE: 22” WIDE, CAST ALUMINUM, ADJUSTABLE, FLOATING ARM BRUSH: 19” LONG BRUSH SPEED /HP: 1000 RPM / 1/4 HP SOLUTION PUMP: 100 PSI, DIAPHRAGM STYLE W/ VARIABLE FLOW (0.2GPM/2.0 GPM) SOLUTION CAPACITY: 20 GALLONS RECOVERY CAPACITY: 20 GALLONS WHEELS: FRONT (4” DIA.), REAR (10” DIA.) SPRAY S
ملخص المحتوى في الصفحة رقم 12
OPERATION INSTRUCTIONS Main Controls: Your Marathon 2000 extractor is equipped with (4) main switches, which control the spray bar, the brush motor, the vacuum motor and the main power. The main switch must be activated before operating the transaxle drive. The machine will glide easily across the floor when pushed forward (without power). The machine will also be able to be pulled back easily when the power is on or off. The pump spray and brush will only be activated when the deadman switch is
ملخص المحتوى في الصفحة رقم 13
Set Up and Operation: Your Marathon 2000 is shipped complete and ready for carpet cleaning. This style of machine is sometimes referred to as a self-contained extractor, since everything is included in the body of the Marathon 2000 extractor. 1. Install recovery tank cover to the top of the tank and connect the suction hose to the cover. 2. Important! – Prior to first use: The unit has been tested with window washer fluid at the factory, and a small amount of this fluid may remain in the system
ملخص المحتوى في الصفحة رقم 14
15. While cleaning, pre-spray traffic areas and spots using the spray wand. The spray wand is attached to a quick disconnect and is pressurized when the MAIN SWITCH is turned on. WARNING: To avoid serious injury: Disconnect power before servicing. Electrical service must be performed by an authorized service station or electrician. Use only nonflammable commercial chemicals intended for machine application. Do not use where explosive vapors or dust are present in the air. Disconnect power if the
ملخص المحتوى في الصفحة رقم 15
Be sure to use Tornado genuine parts and service is provided by an authorized Tornado Service Center. Use of non-O.E.M. parts will void the warranty. PROTECT FROM FREEZING - Caution! If it becomes necessary to store in temperatures that could drop below 40 degrees F, the pumping system, hoses and valves must be protected from freezing with a methyl hydrate window washer antifreeze solution. Do not use ethylene glycol or cooling system antifreezes. Whenever unit will be stored in temperatures
ملخص المحتوى في الصفحة رقم 16
Troubleshooting Table: Problem Solution No Power, Nothing Works * Plug in Cord, Check Circuit Breakers * Activate Main Power Switch * Check For Loose Wiring * Call Service Machine Will Not Move Forward * Reset Circuit Breaker * Turn Speed Control Knob Clockwise * Call Service Brush Does Not Rotate * Reset Circuit Breaker * Activate Brush Switch * Check For Loose Wiring * Call Service Poor Water Spray * Spray Jets Clogged-Remove Spray Bar and Clean Spray Jets * Check Pump-Remove Spray Bar A