ملخص المحتوى في الصفحة رقم 1
SMART-BATT-II Remote Control Kits
- Installation and Operating Instructions -
FCC REQUIREMENTS
INTRODUCTION
The remote control system can be operated thermostati-
WARNING: CHANGES OR MODIFICATIONS TO
cally or manually from the transmitter. The system oper-
THIS UNIT NOT EXPRESSLY APPROVED BY THE
ates on radio frequencies (RF) within a 20 foot range. Can
PARTY RESPONSIBLE FOR COMPLIANCE COULD
be used with IPI or Standing Pilot systems.
VOID THE USER'S AUTHORITY TO OPERATE THE
EQUIPMENT.
This remo
ملخص المحتوى في الصفحة رقم 2
HEARTH MOUNT WIRE TERMINALS The remote receiver can be placed on the fireplace hearth (see Figure 1), or under the fireplace behind the control access panel. Position it close to the front in the right or left corner where the ambient tempera- 0 ture inside the receiver case does not exceed 120 F. NOTE: The remote receiver will only respond to trans- mitter when the switch cover on the receiver is in the REMOTE position. If the system does not respond to the transmitter, see MATCHING SECURITY O
ملخص المحتوى في الصفحة رقم 3
FOR USE WITH REMOTE OR WALL SWITCH ONLY MALE FEMALE RED BROWN MALE FEMALE REMOTE RECEIVER VALVE BOX ON/OFF REMOTE SWITCH Figure 4. Millivolt with Rocker Switch and Receiver If your fireplace is wired like Figure 3 find the leads on back of the switch marked “For use with remote or wall switch only” and take the leads and plug them into wire lead on remote receiver box (see Figure 4). B. Wiring Millivolt Valve with 3-Wire Assembly 3-WIRE ASSEMBLY PILOT PIEZO THERMOCOUPLE WHITE RED VALVE Figur
ملخص المحتوى في الصفحة رقم 4
REMOTE RECEIVER PIEZO PILOT THERMOCOUPLE WIRE TERMINALS WHITE LEARN RED ON/OFF REMOTE SWITCH VALVE Figure 6. Millivolt with Receiver C. Wiring Intermittent Pilot Ignition (IPI) with Rocker Switch INTERMITTENT PILOT I IGNITION MODULE IGNITOR 3 VAC S BLACK WIRE CAN BE PLUGGED INTO ANY OF WHT #1 - #5 LOCATIONS ON THE HOT SIDE ORG GROUND TO FIREPLACE CHASSIS WHITE WIRE CAN BE PLUGGED INTO ANY OF #1-#5 LOCATIONS ON THE NEUTRAL SIDE TRANSFORMER 3 VAC VALVE PLUG IN PIGGYBACK ON/OFF SWITCH Figure 7.
ملخص المحتوى في الصفحة رقم 5
NEUTRAL 5 4 3 2 1 5 4 3 2 1 HOT If your fireplace look like Figure 7 find the leads on the back of switch marked “For use with remote or wall switch only”. Take the leads and plus them into wire leads on remote receiver box (see Figure 8). I INTERMITTENT REMOTE PILOT RECEIVER IGNITOR S IGNITION MODULE 3 VAC ON/OFF SLIDE SWITCH WIRE TERMINAL TRANSFORMER WHITE 3 VAC ORANGE GROUND TO FIREPLACE CHASSIS PLUG IN BATTERY PACK For use with VALVE remote or wall switch only BLA
ملخص المحتوى في الصفحة رقم 6
NEUTRAL NEUTRAL 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 HOT HOT BLACK RED D. Wiring Intermittent Pilot Ignition (IPI) with 3-Wire Assembly IGNITION INTERMITTENT PILOT IGNITOR MODULE 3 VAC I S TRANSFORMER 3 VAC PLUG IN WHITE BATTERY PACK ORANGE GROUND TO FIREPLACE CHASSIS THERMOSTAT WIRE ASSEMBLY JUMPER WIRE (TO BROWN) Figure 9. VALVE If your fireplace looks like Figure 9 remove the 3-wire off the jumper wire by unplugging the spade fr
ملخص المحتوى في الصفحة رقم 7
NOTE: The remote receiver houses the microprocessor that TRANSMITTER responds to commands from the transmitter to control sys- Important: Before operating remote control, transmit- tem operation. It emits one beep when it receives an ON or ter and receiver must have matching security codes. OFF command manually, but no beep when cycling on and See section ‘Matching Security Codes’. off automatically in THERMO mode. The remote receiver has a 3-position slide switch: OFF/RE- Important: Review ‘The
ملخص المحتوى في الصفحة رقم 8
MODE SET UP TIMER DOWN TIME 1. LOW - Battery power low. Replace batteries within two weeks. 2. TIMER - Indicates time remaining before system shuts off, when timer-programmed, 9 - hour maximum setting. 3. MODE - Indicates operation MODE of system. ON indicates the system is on, either manually or thermostatically. THERMO indicates the system will automatically cycle ON/OFF, depending on programmed SET temperature. OFF indicates the entire system is turned off. LCD DISPLAY SCREEN 4. SET - Indica
ملخص المحتوى في الصفحة رقم 9
1. Press the MODE button to place the transmitter into THERMO mode. THERMO ON or OFF will display. 2. Press the UP or DOWN button to select the desired ON 0 room temperature. The highest SET temperature is 99 0 0 0 F (32 C). The lowest SET temperature is 45 F (6 C). 78F ROOM NOTE: To prevent repeated thermo-cycling of the gas appli- ance, the sensing unit in the transmitter will only activate AM SETTING : 800 the remote receiver when the temperature change exceeds BUTTON 0 0 2 F (1 C) above or
ملخص المحتوى في الصفحة رقم 10
Child Proof Lockout (CP) overridden and the system will return to normal operation The transmitter contains a “Child Proof” lockout feature that depending on the MODE selected at the transmitter. prevents unauthorized use of the remote control. To access We recommend the user check the batteries in the TRANS- the “Child Proof” activation button, remove cover on BACK of MITTER to make sure the voltage is no less than 2.7 volts. transmitter. To activate LOCKOUT: Auto Shutdown 1. Press and hold in
ملخص المحتوى في الصفحة رقم 11
4. Then press the MODE button on the transmitter to change GENERAL INFORMATION the system to ON. The spark electrode should begin Transmitter Wall Bracket sparking to ignite the pilot. After the pilot is lit, the main The transmitter can be hung on a wall using the bracket gas valve should open and the main gas flame should provided. Locate the bracket on an inside wall sufficiently ignite. far away from direct sources of heat such as a fireplace, 5. Press the MODE button on the transmitter to O
ملخص المحتوى في الصفحة رقم 12
• Cause the RF signal to get lost and not communi- Troubleshooting cate with the receiver. To check the operation of the remote: 1. Make sure receiver batteries are installed properly. If one • Cause the working distance to be shorter than nor- battery is installed backward, receiver will not operate in mal. remote mode. Be sure battery output is 5.3 volts or more. NOTE: A receiver located in an area, where the ambient (Slide switch is independent of battery condition). 0 temperature inside the