ملخص المحتوى في الصفحة رقم 1
HSU-07HV03/R2(DB)
HSU-09HV03/R2(DB)
HSU-09HV03/R2(SDB)
HSU-12HV03/R2(DB)
HSU-12HV03/R2(SDB)
HSU-18HV03/R2(DB)
No, 0010552537
ملخص المحتوى في الصفحة رقم 2
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner
ملخص المحتوى في الصفحة رقم 3
Cautions Disposal of the old air conditioner Safety Instructions and Warnings Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inop- information given in the User's Guide caref- erative and safe. Unplug the air conditioner ully. The User's Guide contains very impor- in order to avoid the risk of child entrapment. tant observations relating to the assembly, operation and maintenance of the air It must be noticed that
ملخص المحتوى في الصفحة رقم 4
Cautions 7. The appliance is not intended for use Do not obstruct or cover the ventilation by young children or infirm persons grille of the air conditoner.Do not put fingers without supervision. or any other things into the inlet/outlet and swing louver. 8. Young children should be supervised to ensure that they do not play with Do not allow children to play with the air the applience. conditioner.In no case should children be allowed to sit on the outdoor unit. 9.Ple
ملخص المحتوى في الصفحة رقم 5
Cautions Safety Instruction Please read the following Safety Instructions carefully prior to use. The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Installation WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water
ملخص المحتوى في الصفحة رقم 6
Cautions WARNING When abnormality such as burnt-small found, Use an exclusive power source with a immediately stop the operation button and circuit breaker contact sales shop. STRICT OFF ENFORCEMENT Connect power supply cord Use the proper voltage Do not use power supply cord to the outlet completely extended or connected in halfway STRICT STRICT PROHIBITION ENFORCEMENT ENFORCEMENT Do not insert objects into the air Do not use power supply cord Take care not to damage the power supply cord. in
ملخص المحتوى في الصفحة رقم 7
Parts and Functions Indoor unit Outlet Display board Air filter(inside) Inlet UV light degerming Air Purifying Filter device (inside) (inside) (Only for the units of SDB) Inlet grille Anion generator (inside) Vertical flap (adjust up and down air flow. Power plug Don't adjust it manually) Horizontal louver (adjust left and right air flow) Outdoor unit HSU-07HV03/R2(DB) HSU-09HV03/R2(SDB) HSU-09HV03/R2(DB) HSU-12HV03/R2(SDB) HSU-12HV03/R2(DB) HSU-18HV03/R2(DB) 1 5 CHANGE-FOR-FRESH-AIR TUBE OU
ملخص المحتوى في الصفحة رقم 8
Parts and Functions 19 18 34 24 16 17 9. HEALTH button Used to set healthy operation. 10. ON/OFF button Used for unit start and stop. 11. TIMER ON display 12. FAN SPEED display LOW HI MED AUTO 28 13. LOCK display FRESH 14. SWING UP/DOWN display 15. SLEEP display 16. HEALTH display STERILIZE 17.FRESH AIR display 18. Operation mode display Operation mode AUTO COOL DRY HEAT FAN 33 Remote controller Display board 19.Singal sending display 20. UV light degerming function display 21. Left/right air
ملخص المحتوى في الصفحة رقم 9
Parts and Functions 19 18 33 24 16 17 9. HEALTH button Used to set healthy operation. 10. ON/OFF button Used for unit start and stop. 11. TIMER ON display 12. FAN SPEED display LOW MED HI AUTO 28 13. LOCK display 14. SWING UP/DOWN display 15. SLEEP display 30 16. HEALTH display 31 17.FRESH AIR display 18. Operation mode display 32 Operation mode AUTO COOL DRY HEAT FAN Remote controller Display board 19.Singal sending display 20. POWER/SOFT display 21. Left/right air flow display HSU-07HV03/R2(
ملخص المحتوى في الصفحة رقم 10
Parts and Functions Clock Set When unit is started for the first time and after replacing batteries in FRESH remote controller, clock should be adjusted as follows: 1. Press CLOCK button,"AM" or "PM" flashes. STERILIZE 2. Press or to set correct time. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly. 3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working. Remote controller's operatio
ملخص المحتوى في الصفحة رقم 11
Operation HEALTH operation 1.Unit start Press ON/OFF on the remote controller, unit starts. Remote controller Health function includes health anion function, UV light degerming function and change-for-fresh-air function. 2.Health anion function Press HEALTH button. For each press, is displayed. Air conditioner starts health anion function operation. For twice press, disappears,the operation stops. 3.UV light degerming function Press STERILIZE button ," "and " "displayed on the remo
ملخص المحتوى في الصفحة رقم 12
Operation Auto Operation 1. Unit start Press ON/OFF on the remote controller, unit starts. Remote controller 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select Auto operation On the displaying board,colorful displaying bar will be white. 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting increase 1 C,if kept depressed, it will increase rapidly Every time the butt
ملخص المحتوى في الصفحة رقم 13
Operation Cool Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select COOL operation On the displaying board,colorful displaying bar will be blue. 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting o increase 1 C,if kept depressed, it will increase FRESH rapidly Every time t
ملخص المحتوى في الصفحة رقم 14
Operation Dry Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select DRY operation On the displaying board,colorful displaying bar will be light blue 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting o increase 1 C,if kept depressed, it will increase FRESH rapidly Every tim
ملخص المحتوى في الصفحة رقم 15
Operation Fan Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select FAN operation On the displaying board,colorful displaying bar will be pink. 3.Fan speed selection Press FAN button. For each press, fan speed changes as follows: FRESH Remote controller: LOW MED HI STERILIZE 4.Unit stop Press ON/OFF button, th
ملخص المحتوى في الصفحة رقم 16
Operation Heat Operation 1. Unit start Remote controller Press ON/OFF on the remote controller, unit starts. 2.Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY FAN HEAT Then Select HEAT operation On the displaying board,colorful displaying bar will be red 3.Select temp.setting Press TEMP. button Every time the button is pressed, temp.setting FRESH o increase 1 C,if kept depressed, it will increase rapidly STERILIZE Ever
ملخص المحتوى في الصفحة رقم 17
Operation Air Flow Direction Adjustment 1.Status display of air sending Vertical flap Horizontal louvers Pos.1 Pos.1 Pos.2 Pos.2 Pos.3 Pos.3 FRESH Pos.4 Pos.4 STERILIZE Pos.5 Pos.5 Pos.6 Pos.6 (Auto swing) Pos.7 Pos.8 2.Up and down air flow direction For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN Pos.1 Pos.2 Pos.3 Pos.4 Pos.6 remote controller: : HEAT: remote controller: Pos.5 Pos.4 Pos.3 Pos.2 Po
ملخص المحتوى في الصفحة رقم 18
Operation Sleep Operation SLEEP operation starts SLEEP operation stops Approx.6hrs Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP O Rises 1 C 1 hr mode and bring you a sound sleep. O Use of SLEEP function Rises 1 C 1 hr After the unit starts, set the operation status, then press SLEEP button before which the Unit stop Temp.setting clock must be adjusted and time being set. In COOL, DRY mode Operation Mode 1. In COOL,DRY mode 2. In HEAT mode 1 hours af
ملخص المحتوى في الصفحة رقم 19
Operation Timer On/Off Operation Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode Remote Controller Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash. 3.T
ملخص المحتوى في الصفحة رقم 20
Operation Timer On-Off Operation Set clock correctly before starting TIMER operation. Remote Controller 1. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. 2. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Then select your desired TIMER mode (TIMER ON - OFF). " "will flash. 3.Time setting Press H