ملخص المحتوى في الصفحة رقم 5
100BASE-FX 10/100BASE-TX PWR 1 TX PWR 2 FAULT RX 100M TX RING MASTER RX 100M SISTF10xx-130-LR(T) Operation Operation -- Continued Status LEDs Features Use the status LEDs to monitor the SISTF10xx-130-LR(T) in the network. Auto-Negotiation With the Auto-Negotiation feature, the SISTF10xx-130-LR(T) automatically configures itself to achieve the best possible mode of operation over the The three LEDs near the top indicate the power and fault status: copper link. The device broadcasts its spe
ملخص المحتوى في الصفحة رقم 6
SISTF10xx-130-LR(T) Cable Specifications -- Continued Cable Specifications Copper Cable The physical characteristics must meet or exceed IEEE 802.3™ specifications. Category 5: (minimum requirement) Fiber Cable Gauge: 24 to 22 AWG Bit Error Rate: <10-9 Attenuation: 22.0 dB /100m @ 100 MHz Single mode fiber (recommended): 9 µm Maximum Cable Distance: 100 meters Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm Straight-through OR crossover
ملخص المحتوى في الصفحة رقم 7
SISTF10xx-130-LR(T) Technical Specifications Technical Specifications -- Continued For use with Transition Networks Model SISTF10xx-130-LR(T) or equivalent EMS Type Tests Standards: IEEE 802.3™, 802.3u™; 802.3x™ Test Description Test Levels Severity Data Rate: 10 Mb/s, 100 Mb/s (copper); 100 Mb/s (fiber) IEC61000-4-2 ESD Air discharge +/- 8 KV 3 Contact discharge +/- 6 KV 3 Processing Type: Store and Forward w/ IEEE802.3x™ full-duplex, non-blocking flow control ESD contact discharge +/- 6 KV 3 I
ملخص المحتوى في الصفحة رقم 8
SISTF10xx-130-LR(T) Troubleshooting Troubleshooting -- Continued If the device fails, isolate and correct the fault by determining the answers to the 6. Are either 100M LEDs (near the fiber links) flashing? following questions and then taking the indicated action: NO If there is activity on the corresponding fiber port, disconnect and 1. Is the PWR1 LED illuminated? reconnect the fiber cable to restart the initialization process. NO If there is no activity on the corresponding fiber port, co
ملخص المحتوى في الصفحة رقم 9
Compliance Information UL Listed; C-UL Listed (Canada) NOTE: The following part numbers are UL listed: SISTF1013-130-LR, SISTF1013-130-LRT, SISTF1014-130-LR, SISTF1014-130-LRT. CISPR22/EN55022 Class A CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
ملخص المحتوى في الصفحة رقم 1
User’s Guide
SISTF10xx-130-LR(T)
Stand-Alone Redundant Ring Industrial Switch
• Copper to Fiber
Ethernet / Fast Ethernet
10Base-T / 100Base-TX to 100Base-FX
Extended Temperature
Hazardous Environment
Transition Networks SISTF10xx-130-LR(T) redundant
ring industrial switch connects three (3) 10Base-T /
100Base-TX twisted-pair copper cable lines to two
(2) 100Base-FX fiber-optic cable lines. The
SISTF10xx-130-LR(T) is designed for harsh industrial
environments such as hazardous location
ملخص المحتوى في الصفحة رقم 2
100BASE-FX 10/100BASE-TX 100BASE-FX 100BASE-FX 10/100BASE-TX 10/100BASE-TX 100BASE-FX 10/100BASE-TX 100BASE-FX 100BASE-FX 100BASE-FX 10/100BASE-TX 10/100BASE-TX 10/100BASE-TX TX PWR 1 PWR 2 FAULT RX 100M TX RING MASTER RX 100M FAULT FAULT RX RX 100M 100M TX TX RING MASTER RING MASTER RX RX TX PWR 1 TX PWR 1 100M PWR 2 PWR 2 100M TX PWR 1 PWR 2 FAULT RX 100M TX RING MASTER RX 100M FAULT FAULT RX RX 100M 100M TX TX RING RING MASTER MASTER RX PWR 1 RX TX TX PWR 1 PWR 2 100M PWR 2 10
ملخص المحتوى في الصفحة رقم 3
100BASE-FX 10/100BASE-TX 100BASE-FX 100BASE-FX 10/100BASE-TX 10/100BASE-TX TX PWR 1 PWR 2 FAULT RX 100M TX RING MASTER RX 100M TX PWR 1 TX PWR 1 PWR 2 PWR 2 FAULT FAULT RX RX 100M 100M TX TX RING RING MASTER MASTER RX RX 100M 100M SISTF10xx-130-LR(T) Installation -- Continued Installation -- Continued CAUTION: Disconnect the SISTF10xx-130-LR(T) from the DC power Install the Copper Cable source BEFORE installing and/or wiring the device. The AutoCross feature allows either straight-thro
ملخص المحتوى في الصفحة رقم 4
SISTF10xx-130-LR(T) Installation -- Continued Installation -- Continued Power the SISTF10xx-130-LR(T) Switch 6: Ring Master on: Enables the device to be the Ring Master in a Redundant Ring topology. This device is suitable for use in Class I, Division 2, Groups A, B, C and D or This setting also enables the Redundant Ring break alarm. If a link in the non-hazardous locations only. Redundant Ring breaks (and if the SISTF10xx-130-LR(T) is the Ring WARNING: EXPLOSION HAZARD - Do not disconne