ملخص المحتوى في الصفحة رقم 1
MULTI-TASKER
MANUAL PART NUMBER: 400-0226-003
MT105-110/MT105-111
8/16-IN, 8-OUT SYNC MATRIX SWITCHER
CARDS FOR MULTI-TASKER
USER’S GUIDE
ملخص المحتوى في الصفحة رقم 2
MULTI-TASKER TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS ...............3 GENERAL..........................................................3 INSTALLATION..................................................3 CLEANING.........................................................3 FCC / CE NOTICE..............................................3 ABOUT YOUR MT105-110/111.............................4 TECHNICAL SPECIFICATIONS............................4 DESCRIPTION OF MT105-110/111...................
ملخص المحتوى في الصفحة رقم 3
MULTI-TASKER • This equipment has been tested and found to PRECAUTIONS / SAFETY WARNINGS 1 comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. Please read this manual carefully before using your These limits are designed to provide MT105-110/111. Keep this manual handy for future reasonable protection against harmful reference. These safety instructions are to ensure interference when the equipment is operated the long life of your MT105-110/111 and
ملخص المحتوى في الصفحة رقم 4
MULTI-TASKER ABOUT YOUR MT105-110/111 2 TECHNICAL SPECIFICATIONS 3 MT105-110/MT105-101 FEATURES/ MT105-110/111 DESCRIPTION 8/16-in 8-out Sync Matrix Switcher GENERAL Cards Inputs 8/16 The MT105-110/111 16-in/8-in, 8-out Sync Matrix External Input Connectors 8/16 BNC Female Switcher card is designed for use in the Multi- Outputs 8 Tasker™ enclosure to allow the routing of computer Output Connector 8 BNC Female and broadcast video in audio/visual presentation Compatibility systems. When instal
ملخص المحتوى في الصفحة رقم 5
MULTI-TASKER DESCRIPTION OF MT105-110/111 4 5 5
ملخص المحتوى في الصفحة رقم 6
MULTI-TASKER APPLICATION DIAGRAM 5 6 6
ملخص المحتوى في الصفحة رقم 7
MULTI-TASKER Block Diagrams: Internal View of MT105-110/111 7 7
ملخص المحتوى في الصفحة رقم 8
MULTI-TASKER Commands such as [ON], [OFF], and [IO] that INSTALLING YOUR MT105-110/111 6 end in "S" will be saved into memory. Commands not ending in "S" will still be Step 1. Slide the MT105-110/111 into an available executed but will not be restored when the slot in the Multi-Tasker™ Enclosure in system is reset (power off & power on again). order to connect to the bus. Make sure that the MT105-110/111 card fits into 7.2 DESCRIPTION OF COMMANDS place. Secure the card to the Multi- Eac
ملخص المحتوى في الصفحة رقم 9
MULTI-TASKER Example: Input8 is connected to Output5 and Output5 is disabled If one MT105-110/111 card is in slot #2 of unit Input7 is connected to Output6 and Output6 is 3: disabled When sending command [VERC2U3], the Multi- Input10 is connected to Output7 and Output7 is Tasker™ Enclosure will return feedback as disabled MT105-111 690-0126-011. Input16 is connected to Output8 and Output8 is 2. [C] disabled This command displays the status of the card Note: If there is no card in slot #2
ملخص المحتوى في الصفحة رقم 10
MULTI-TASKER Ix = select input x (x is # from 1 to 16) [ONmGkUiS]: for a group of cards Oy = connect to output y (y is # from 1 to 8) This command enables output "m" for each card in group "k" of unit "i". Cn = card ID number (n is # from 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) m = card output (m = # from 1-8) Ui = unit ID, i is # from 0 to 9). (Refer to MT100- k = group number (k = # from 1-9) 100 user’s guide to set Unit ID). i = unit number (i = # from 0-9) S = saves comma
ملخص المحتوى في الصفحة رقم 11
MULTI-TASKER [ON…..F]: feedback m = card output (m = # from 1-8) After processing a command, an OK or ER will k = group number (k = # from 1-9) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) be returned as feedback if "F" is included at the end of a command string or if the unit ID is zero. i = unit number (i = # from 0-9) Example: S = saves command to memory [ON1C2U3F]: if path is not set Example: [ON1C2U3PF]: if path is set 1. [OFF1G5U1]: Turns OFF output 1 for each card in group5 of
ملخص المحتوى في الصفحة رقم 12
MULTI-TASKER Example: [CLRCnUi]: for a single card [OFF1C2U3F]: if path is not set n = Card ID number (n = 1 to 19) (1 to 8 for MT100-101 or 1 to 4 for MT100-106) [OFF1C2U3PF]: if path is set Ui = Unit ID number (i = 0 to 9) 6. [SW] – Switch Note that all outputs will be connected to input1. The switch command immediately connects [CLRGkUi]: for a group of cards inputs and outputs, which were previously set with the path command on this card or any other Gk = group number (k = # from 1-9)
ملخص المحتوى في الصفحة رقم 13
MULTI-TASKER 10. [RD] TROUBLESHOOTING GUIDE 8 This command displays the members in each We have carefully tested and have found no group. problems in the supplied MT105-110/(111); however, we would like to offer suggestions for the Command Format: [RDGkUi] following: k = group number (k = # from 1-9) NO DISPLAY i = unit number (i = # from 0-9) Cause 1: The source has a problem. member = C1 - C19 (card 1 to 19) (1 to 8 for Solution: Check the source and make sure, that MT100-101 or 1 to 4
ملخص المحتوى في الصفحة رقم 14
MULTI-TASKER ALTINEX POLICY 9 9.0 LIMITED WARRANTY / RETURN POLICY Please see the Altinex website at www.altinex.com for details on warranty and return policy. 9.1 CONTACT INFORMATION ALTINEX, INC. 592 Apollo Street Brea, CA 92821 USA TEL: 714-990-2300 TOLL FREE: 1-800-ALTINEX WEB: www.altinex.com E-MAIL: solutions@altinex.com FAX: 714-990-3303 14 14