ملخص المحتوى في الصفحة رقم 1
INSTALLATION/OPERATION
VS5004/VS5008
Sequential Switcher
®
C808M-G (4/05)
ملخص المحتوى في الصفحة رقم 2
Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Installation . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 3
Description The VS5004 and VS5008 sequential switchers are designed to switch up to four (VS5004) or eight (VS5008) cameras manually or automatically to ® one or two monitors with automatic response to alarm inputs. Both versions are Coaxitron compatible and can be placed on a desktop or rack mounted. MODELS VS5004 Sequential switcher with four camera inputs and two monitor outputs, 120 VAC VS5004/220 Same as VS5004 except 230 VAC VS5008 Sequential switcher with eight camera inputs and
ملخص المحتوى في الصفحة رقم 4
Installation TERMINATED CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Make all equipment connections. Refer to Figure 1 (VS5004) or Figure 2 (VS5008). VS5008 only: When configured for one-monitor operation, the monitor must be connected to the MON 2 output. The MON 1 output must be terminated with a 75-ohm BNC terminator. 2. Make alarm connections if required. Refer to Figure 3 (VS5004) or Figure 4 (VS5008) and do the following: VS5004 a. Input: Connect the alarm contact bet
ملخص المحتوى في الصفحة رقم 5
NOTE: MON 1 MUST BE TERMINATED. CAMERAS MON 1 ALARM COM 12 VAC INPUT 87654321 MON 2 MON X 12345678 INPUT ALARM OUT VS5008 (REAR) Figure 2. VS5008 Terminated Camera Inputs - One Monitor 6-PIN CONNECTOR RECEPTACLE YEL BRN REAR VIEW 4 1 GRN RD BLK 5 2 OR 3 6 CAMERAS 12VAC ALARM INPUT MON 1 3 4 2 1 IN 1 2 3 4 MON 2 4 3 2 1 OUT 6 -- TO VCR COMMON 5 TO EXTERNAL ALARM CIRCUITRY Figure 3. VS5004 Alarm Connections C808M-G (4/05) 5
ملخص المحتوى في الصفحة رقم 6
UP TO EIGHT ALARM INPUTS (ALARM INPUT FROM MOTION DETECTOR, DOOR CONTACT, ETC., THROUGH NORMALLY OPEN SWITCH). EACH ALARM DEVICE MUST BE CONNECTED TO THE "COM" TERMINAL. UP TO EIGHT VIDEO INPUTS CAMERAS MON 1 ALARM COM 12 VAC INPUT 87654321 MON 2 MON X 12345678 INPUT ALARM OUT VS5008 (REAR) VCR OPEN COLLECTOR OUTPUT FOR VCR ACTIVATION IN ALARM CONDITION. ONLY ONE VCR CAN BE USED IN THIS CONFIGURATION. Figure 4. VS5008 Alarm Connections 6 C808M-G (4/05)
ملخص المحتوى في الصفحة رقم 7
LOOPING CAMERA INPUTS AND ONE MONITOR OUTPUT 1. Convert the switcher to looping operation. Refer to Figure 5 and do the following: NOTE: Looping and terminated inputs may be mixed. a. Remove the cover. b. Remove the rear panel of the chassis. c. Locate the 75-ohm resistors located on the inside of the rear panel BNC jacks. d. For each input to be looped, use wire cutters to clip one of the attached resistor leads. e. Replace the cover. 2. Make all equipment connecti
ملخص المحتوى في الصفحة رقم 8
75-OHM RESISTOR CLIP HERE FOR EACH CHANNEL REAR PANEL (SWITCHER) BNC CONNECTOR Figure 5. Looping Conversion Modification MON 1 BRIGHT CONTRAST 12 VAC INPUT ALARM MON 1 43 2 1 IN 1 2 3 4 OUT 6 MON 2 COMMON 5 VIDEO INPUTS ADDITIONAL EQUIPMENT TERMINATED Figure 6. VS5004 Looping Camera Inputs - One Monitor 8 C808M-G (4/05)
ملخص المحتوى في الصفحة رقم 9
NOTE: IN THIS CONFIGURATION, MON 1 MUST BE TERMINATED AND THE UNIT MUST BE MODIFIED TO BE LOOPING (REFER TO FIGURE 5). CAMERAS MON 1 ALARM COM 12 VAC INPUT 87654321 MON 2 MON X 12345678 INPUT ALARM OUT VS5008 (REAR) VIDEO INPUTS ADDITIONAL EQUIPMENT TERMINATED Figure 7. VS5008 Looping Camera Inputs - One Monitor TERMINATED CAMERA INPUTS AND TWO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover. b. R
ملخص المحتوى في الصفحة رقم 10
4. Set the ALARM switch to the ON position. NOTES: • With all channel switches set to the AUTO position, both monitors immediately switch to the alarmed channel and the associated LED blinks. Multiple alarmed channels sequence every five seconds (VS5004) or three seconds (VS5008). The alarm has priority over the MONITOR/AUTO/BYPASS switch settings. • If a channel switch is set to the MONITOR position, Monitor 1 switches to the alarmed channel while Monitor 2 displays
ملخص المحتوى في الصفحة رقم 11
MON 2 MON 1 BRIGHT CONTRAST BRIGHT CONTRAST 12 VAC INPUT ALARM MON 1 43 2 1 IN 1 2 3 4 OUT 6 MON 2 COMMON 5 NOTE: IN THIS CONFIGURATION, MON 1 MUST BE TERMINATED WITH A 75-OHM TERMINATOR AND MON 2 MUST BE IN THE “HI Z” POSITION. Figure 9. VS5004 Terminated Camera Inputs - Two Monitors CAMERAS MON 1 ALARM COM 12 VAC INPUT 87654321 MON 2 MON X 12345678 INPUT ALARM OUT VS5008 (REAR) Figure 10. VS5008 Terminated Camera Inputs - Two Monitors C808M-G (4/05) 11
ملخص المحتوى في الصفحة رقم 12
LOOPING CAMERA INPUTS AND TWO MONITOR OUTPUTS 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover. b. Remove the rear panel of the chassis. c. Remove the four screws attaching the PC board to the chassis. d. Pull the PC board and rear panel assembly out of the chassis. e. Turn the PC board over and rewire. 2. Convert to looping operation. Refer to Figure 5 and do the following: NOTE: Looping and term
ملخص المحتوى في الصفحة رقم 13
7. Connect the AC adapter to the 12 VAC input plug on the rear of the VS5004 or VS5008. Connect the transformer to a 120 VAC (VS5004 or VS5008) or 230 VAC (VS5004/220 or VS5008/220) power source. After power up, the switcher will begin sequencing. 8. Using a screwdriver, adjust the DWELL interval control to the desired setting. This control adjusts the interval time from a minimum of 1 second to a maximum of 70 seconds nominal. To increase the interval, turn the control clockwis
ملخص المحتوى في الصفحة رقم 14
COAXITRON CONTROL To convert for use with a Coaxitron transmitter, do the following: 1. Convert the VS5004 to dual-monitor operation. Refer to Figure 8 and do the following: a. Remove the cover. b. Remove the rear panel of the chassis. c. Remove the four screws attaching the PC board to the chassis. d. Pull the PC board and rear panel assembly out of the chassis. e. Turn the PC board over and rewire. 2. Convert to looping operation. Refer to Figure 5 and do the fo
ملخص المحتوى في الصفحة رقم 15
6. For channels with cameras connected to the video inputs, set the front panel switches to the AUTO position. All unconnected video inputs should have their channel switch set to the BYPASS position. NOTES: • VS5004 and VS5008 with one-monitor configuration: All channels with a switch set in the AUTO position will automatically sequence through the monitor. To view one specific channel continuously, set the corresponding switch to the MONITOR position. To remove a channel from th
ملخص المحتوى في الصفحة رقم 16
MON 1 COAXITRON® RECEIVER TO FIXED CAMERAS OR ADDITIONAL RECEIVERS BRIGHT CONTRAST 12 VAC INPUT ALARM MON 1 43 2 1 IN 1 2 3 4 OUT 6 MON 2 COMMON 5 VS5004 (REAR) LOOPING INPUT FROM OUTPUT FROM OUTPUT RECEIVER MONITOR J8 J7 J6 COAXITRON® TRANSMITTER (REAR) Figure 13. VS5004 with Coaxitron Control COAXITRON RECEIVER UP TO EIGHT RECEIVERS CAMERAS MON 1 ALARM COM 12 VAC INPUT 87654321 MON 2 MON X 12345678 INPUT ALARM OUT VS5008 (REAR) LOOPING INPUT FROM OUTPUT TO OUTPUT
ملخص المحتوى في الصفحة رقم 17
Specifications VIDEO Inputs Terminating (75 ohms) or looping Outputs Monitor 1 75 ohms Monitor 2 VS5004 Hi Z VS5008 75 ohms Monitor X VS5008 Coaxitron transmitter (nonamplified) output Gain Unity Dwell Adjustable from 1-70 seconds nominal Frequency Response Flat within +/-1 dB to 10 MHz Maximum Signal Level 2 Vp-p Tilt Less than 2% Crosstalk Better than -40 dB at 5.5 MHz ELECTRICAL Power Requirements for Transformer 1.5 VA (0.125 A) at 12 volts RMS +/-15%, 50/60 Hz
ملخص المحتوى في الصفحة رقم 18
18 C808M-G (4/05)
ملخص المحتوى في الصفحة رقم 19
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or workmanship for a period of one year after the date of shipment. (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: Exceptions to this warranty are as noted below: 1. Model and serial number 2. Date of shipment, P.O. number
ملخص المحتوى في الصفحة رقم 20
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO9001 United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East | | | | | | | |