Part No. 204518-B
April 2000
4401 Great America Parkway
Santa Clara, CA 95054
Installing the Passport 8010
Chassis
ملخص المحتوى في الصفحة رقم 2
Copyright © 2000 Nortel Networks All rights reserved. April 2000. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks NA In
ملخص المحتوى في الصفحة رقم 3
Japan/Nippon Requirements Only Voluntary Control Council for Interference (VCCI) Statement Taiwan Requirements Bureau of Standards, Metrology and Inspection (BSMI) Statement Canada Requirements Only Canadian Department of Communications Radio Interference Regulations This digital apparatus (Passport 8010 Chassis) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications. Règle
ملخص المحتوى في الصفحة رقم 4
iv
ملخص المحتوى في الصفحة رقم 5
About this Guide ™ This guide provides information about installing and using the Passport 8010 Chassis. It includes the following information: Requirements for the operating environment of the chassis Instructions for attaching rack-mounting brackets Instructions for installing the chassis Instructions for installing one or more power supplies in the chassis Instructions for installing cable guides Instructions for installing a module in the chassis Specifications for the chassi
ملخص المحتوى في الصفحة رقم 6
Before You Begin The physical requirements for installing the Passport 8010 Chassis in an equipment rack are: Adequate room (13.1 spaces) is provided in an EIA or IEC standard 19-inch (48.2-centimeter) equipment rack that is: — Bolted to the floor — Braced if necessary — Grounded 3 in = 7.6 cm Side rail dimensions are similar to this illustration. Typical racks with these dimensions are the Chatsworth Products, Inc. (CPI) rack and the B-Line rack. 9114FA At least 6 inches (15.2 cm)
ملخص المحتوى في الصفحة رقم 7
Unpacking 1 3 2 4 5 6 7 9 8 9073FA 1 = Passport 8010 Chassis 2 = Power Supply (one or more—ordered separately) 3 = Documentation 4 = Power cord (optional) 5 = DB-25 to DB-9 adapter for use with comm port cable 6 = Comm port cable for Passport 8132TX module, purchased separately 7 = Rack mounting brackets 8 = Screws for brackets and equipment rack 9 = Cable guides For detailed information about the comm port cable for the Passport 8132TX Switch Module, refer to the documentation that was shipped
ملخص المحتوى في الصفحة رقم 8
Attaching the Rack-Mounting Brackets Required tool: Phillips screwdriver Note: Each bracket fits only one side of the chassis. If the mounting holes do not line up between a bracket and the chassis, try that bracket against the other side of the chassis. 9103FA 9104FA 2. Insert the supplied flat-head screws to fasten 1. Hold each rack-mounting bracket against each bracket to the chassis. one side of the chassis. Make sure the attachment holes in the bracket match the holes in the chassis. 4
ملخص المحتوى في الصفحة رقم 9
Installing the Chassis in a Rack Required tool: Phillips screwdriver 9074FA 9075FA 1. Slide the chassis into the rack. 2. Insert and tighten the rack-mounting screws. To complete the installation process, refer to “Installing the Power Supply.” 5
ملخص المحتوى في الصفحة رقم 10
Installing the Power Supply Required tool: Phillips screwdriver 8957FA 8958FA 1. If necessary, remove the filler panel from a 2. Push the supply firmly into the bay. power supply bay. Note: If you are installing a power supply in a new chassis, be sure to remove the bag of dessicant from the middle power supply bay. 8959FA 8960FA 4. Connect the power cord to the power supply 3. Align and tighten the retaining screws. and to an AC power outlet that is on a circuit with no other equipment conne
ملخص المحتوى في الصفحة رقم 11
8964FA 5. Turn on the power switch. Note: In a newly installed chassis that requires two power supplies (nonredundant configuration), you must turn on both units within 2 seconds of each other. If you wait longer to turn on the second power supply, both power supplies will turn off. To correct this condition, turn off both power supplies, wait at least 30 seconds, and turn both power supplies on again within 2 seconds. Operational Notes for the Power Supply A Passport 8010 Chassis with up to
ملخص المحتوى في الصفحة رقم 12
Attaching a Cable Guide Attach the cable guides to the left side of the chassis so the bundled cables will not obstruct airflow to the right side of the chassis. 9105FA 9106FA 2. Slide the guide onto the loosened screws. 1. Loosen, but do not remove, the rack-mounting screws needed to install one cable guide. 9107FA 3. Tighten the screws to secure the guide to the chassis. 8
ملخص المحتوى في الصفحة رقم 13
Installing a Module For details about the operation of modules, refer to the documentation that was shipped with each module. Required tool: Phillips screwdriver 9058FA 9059FA 1. Remove a filler panel from a module slot. 2. Make sure the inserter/extractor levers are rotated away from the front of the module. 9060FA 9070FA 3. Align the module circuit board with the card 4. Rotate the inserter/extractor levers to seat the guides in the chassis. Slide the module into a backplane connectors. slo
ملخص المحتوى في الصفحة رقم 14
9071FA 5. Align and tighten the retaining screws. Chassis Specifications Environmental Specifications Operating temperature: 0° to 40° C (32° to 104° F) Storage temperature: –25° to 70° C (–13° to 158° F) Operating humidity: 85% maximum relative humidity, noncondensing Storage humidity: 95% maximum relative humidity, noncondensing Operating altitude: 3,024 m (10,000 ft) Physical Specifications Height: 22.9 in. (58.2 cm) Width: 17.5 in. (44.5 cm) Depth: 19.9 in. (50.5 cm) Weight (Empty): 85 l
ملخص المحتوى في الصفحة رقم 15
Electrical Specifications System Line Frequency 47 to 63 Hz System with one power supply or two supplies in redundant configuration: Input Volt Amperes Rating: 1,236 VA maximum Input Power: 1,112 W maximum Input Voltage: 100-240 VAC Input current: 12 to 6 A per line cord Thermal rating: 3,792 BTU per hour maximum System with two power supplies (nonredundant) or three supplies in redundant configuration: Input Volt Amperes Rating: 2472 VA maximum Input Power: 2224 W maximum Input Voltage: 100-240
ملخص المحتوى في الصفحة رقم 16
12