ملخص المحتوى في الصفحة رقم 1 
                    
                         
 
 
 
DX User IP  
User Guide 
 
 
 
 
 
 
 
www. m i n i c o m .c o m  
International HQ North American HQ European HQ 
Jerusalem, Israel Linden, NJ, USA Dübendorf, Switzerland 
Tel: + 972 2 535 9666 Tel: + 1 908 4862100 Tel: + 41 44 823 8000 
minicom@minicom.com info.usa@minicom.com 
info.europe@minicom.com 
Customer support - support@minicom.com 
5UM20140 V1.3 7/06 
                                                                                                                              
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        DX USER IP  Table of Contents  1. Welcome.................................................................................................................3  2. Introduction............................................................................................................4  3. Features of DX User IP ...........................................................................................5  4. DX User IP components ........................................................................
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        USER GUIDE  40. Maintenance ......................................................................................................... 50  41. Accessing the remote console............................................................................. 54  42. Keyboard layout ................................................................................................... 54  43. The Control buttons /toolbar icons ...................................................................... 55  44. The Ch
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        DX USER IP  1. Welcome  Thank you for buying the DX User IP system. The DX User IP system is produced  by Minicom Advanced Systems Limited.  Technical precautions   This equipment generates radio frequency energy and if not installed in accordance  with the manufacturer’s instructions, may cause radio frequency interference.   This equipment complies with Part 15, Subpart J of the FCC rules for a Class A  computing device. This equipment also complies with the Class A limits for radio  noise emi
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        DX USER IP  3. Features of DX User IP  • KVM (keyboard, video, mouse) access over IP or analogous telephone line.   • Automatically senses video resolution for best possible screen capture   • High-performance mouse tracking and synchronization   • Connect a user console for direct access to KVM switch   • Local Mouse suppression (only when using SUN's Java Virtual Machine)   DX User IP supports PS/2 type keyboards and mice and HD 15 video output. See  the pin assignments in Appendix C.   4. DX 
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        www.minicom.com USER GUIDE  6. DX User IP front panel  Figure 2 illustrates the DX User IP front panel.  DXU - IP MINICOM Activity System OK   Figure 2 Front panel  The table below explains the functions of the front panel LEDs.  LED Function  Activity LED blinks when a remote user operates the DXU IP  System OK LED solid when DX User IP connected and functioning    7. DX User IP rear panel  Figure 3 illustrates the rear panel of the DX User IP.  RS232 Serial USB Monitor port ports SERIAL I USER
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        www.minicom.com DX USER IP  Terminal port  When there are X-RICC RS232s in the DX system, you can control them through an  RS232 terminal connected to the DX User IP.   Ethernet - Connects the DX User IP to an Ethernet network.  8. Rack mounting the DX User IP  Use the L-shaped brackets and screws provided to mount the DX User IP on a  server rack as illustrated below.  Insert screws to connect to rack SERIAL I USER 0 RST SYSTEM POWER USB TERMINAL ETHERNET 100-240 VAC 50/60 Hz Insert screws to c
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        USER GUIDE  Windows 2000 Pro and 2000 Server  Deactivate Mouse Acceleration.  To do so:  From the Control Panel select Mouse. Select the Motion tab. See Figure 5.    Figure 5 Motion tab  The Speed section slider bar must be in the center, and the Acceleration section  must be set to None. Click OK to save changes.  Windows XP and 2003 Server  Deactivate Enhanced pointer precision. To do so:  From the Control Panel select Printers and Other Hardware. Click the Mouse  icon. The Mouse Properties bo
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        www.minicom.com DX USER IP  The Motion section slider bar must be in the center, and the Enhanced pointer  precision box must be unchecked. Click OK to save changes.  Disable Active Desktop  Disable Active Desktop, or do not use a plain background, use wallpaper.  11. DX User IP connections  Figure 7 below illustrates the connections of the DX User IP to the DX system. See  below for more details.  P1 10 SD SERIAL USER I 0 RST SYSTEM POWER USB TERMINAL ETHERNET 100-240 VAC 50/60 Hz Ethernet CAT5
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        www.minicom.com USER GUIDE  10 Mbps connection   For 10BASE-T Ethernet networks, the Fast Ethernet adapter uses Category 3, 4, or 5  UTP/FTP cable. To establish a 10 Mbps connection, the cable must be connected to  a 10BASE-T hub. Ensure the cable is wired appropriately for a standard 10BASE-T  adapter. Align the RJ-45 plug with the notch on the adapter's connector and insert it  into the adapter's connector.   100 Mbps connection   For 100BASE-TX Fast Ethernet networks, the DX User IP supports 
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        DX USER IP  15. Order of powering on   Connect the DX User IP to the power supply using the power cord provided.  The devices and servers can be powered on at any time. Power on the DX  components in the following order:  1. The primary and secondary level DX Centrals.  2. The DX User and DX User IP units.   16. Configuring the system   The DX User IP's communication interfaces are based on TCP/IP, and it comes  configured with the values listed below.  • DHCP - disabled   • IP address - 192.168
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        USER GUIDE  1. Choose Start/Programs/Accessories/Communications/Hyperterminal.  2. When prompted enter a name and click OK. The Connect To box appears.  See Figure 9.   3. Fill in the connection details. Select COM 1 in the Connect using box and  click OK. The COM 1 properties box appears. See Figure 10.    Figure 9 Connect To box    Figure 10 COM 1 Properties box  12                                                                                                                                  
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        DX USER IP  4. Set the port settings to the following values:   • Bits/second - 115200  • Data bits - 8   • Parity - None   • Stop bits - 1   • Flow Control - None   5. Click OK. The Hyperterminal appears. See Figure 11.    Figure 11 The Hyperterminal  6. Press Enter. Some device information and a prompt appear.   7. Type config and press Enter. Configuration questions appear. DHCP must be  disabled. You can change the IP address, net mask and default gateway. Pressing  Enter without entering va
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        USER GUIDE  Via Ethernet Crossover connection  Connect an Ethernet Crossover cable to the DX User IP and to the computer back- to-back, the DX User IP is configured to 192.168.1.22, configure your computer to  use a static IP in that range. For example 192.168.1.10. Open your browser and type  192.168.1.22. Configure the device via the WEB interface.  Via the IP Device Setup utility  The IP Device Setup utility is located on the supplied CD under Customer  Support/Utilities. Click the IP Device 
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        DX USER IP  This section deals with the HTTP interface. The other two interfaces are explained  on pages 19 and 45.   The Web browser must come with a Java Runtime Environment version 1.1 or  higher. Without Java support, you can still maintain the remote host system using  the administration forms displayed by the browser.   We recommend the following browsers for an unsecured connection:   • For Windows 98, ME, 2000 and XP, Microsoft Internet Explorer 5.0 or  higher  • For Windows 98, ME, 2000
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        USER GUIDE      Figure 14 The DX User IP Home page  19. Timeout  After half an hour of non-activity the system automatically logs out. Clicking  anywhere on the screen will lead back to the Login screen.   20. The Work area  The Work area has a short summary about your DX User IP.  • Server Power Status - On or Off   • Firmware Version - installed on your DX User IP  • Device management – self managed or connected to a management device  • Users - all currently logged in users and IP addresses. 
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        DX USER IP    Figure 15 The Remote Console Settings  All settings are user specific. Choose a user from the Drop-down menu.  Transmission Encoding  Transmission Encoding optimizes the speed of the remote screen depending on the  number of parallel users and the bandwidth of the connection line.  Automatic Detection - The encoding and the compression level is determined  automatically from the available bandwidth and the current content of the video  image.  Pre-configured – Choose the connection
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        USER GUIDE  Various Remote Console Options  Start in Monitor Mode - Check this option to open the Remote Console window in  read only mode. (No keyboard or mouse transferred to Host computer).  Exclusive Access- Enables the Exclusive Access mode at Remote Console startup.  This forces the Remote Consoles of all other users to close. No one can open the  Remote Console until this user disables the Exclusive Access or logs off.  Remote Console Type  Default Java VM – Uses your Browser’s default Ja
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        DX USER IP  To require a confirmation request before keystrokes are sent, write confirm at the  start. E.g. confirm Ctrl+Alt+Delete.  For a list of key codes and aliases DX User IP recognizes, refer to Appendix B on  page 63.   Press Apply for the changes to take effect.   Home Page Refresh – Refreshes the DX User IP Home page, so that direct Smart  IP Links updates their status.  22. Telnet Console   The Telnet Console offers a Java applet for the Telnet protocol to open a connection  to DX Use