ملخص المحتوى في الصفحة رقم 1
General-Purpose AC Servo
J2M Series
SSCNET Compatible
MODEL
MR-J2M-P8B
MR-J2M- DU
MR-J2M-BU
SERVO AMPLIFIER
INSTRUCTION MANUAL
G
ملخص المحتوى في الصفحة رقم 2
Safety Instructions (Always read these instructions before using the equipment.) Do not attempt to install, operate, maintain or inspect the units until you have read through this Instruction Manual, Installation Guide, Servo Motor Instruction Manual and appended documents carefully and can use the equipment properly. Do not use the units until you have a full knowledge of the equipment, safety information and instructions. In this Instruction Manual, the safety instruction levels are classifi
ملخص المحتوى في الصفحة رقم 3
1. To prevent electric shock, note the following: WARNING Before wiring or inspection, switch power off and wait for more than 15 minutes. Then, confirm the voltage is safe with voltage tester. Otherwise, you may get an electric shock. Connect the base unit and servo motor to ground. Any person who is involved in wiring and inspection should be fully competent to do the work. Do not attempt to wire for each unit and the servo motor until they are installed. Otherwise, you can obtain the electri
ملخص المحتوى في الصفحة رقم 4
4. Additional instructions The following instructions should also be fully noted. Incorrect handling may cause a fault, injury, electric shock, etc. (1) Transportation and installation CAUTION Transport the products correctly according to their masses. Stacking in excess of the specified number of products is not allowed. Do not carry the servo motor by the cables, shaft or encoder. Do not hold the front cover to transport each unit. Each unit may drop. Install the each unit in a load-bearing p
ملخص المحتوى في الصفحة رقم 5
(2) Wiring CAUTION Wire the equipment correctly and securely. Otherwise, the servo motor may misoperate. Do not install a power capacitor, surge absorber or radio noise filter (FR-BIF option) between the servo motor and drive unit. Connect the output terminals (U, V, W) correctly. Otherwise, the servo motor will operate improperly. Connect the servo motor power terminal (U, V, W) to the servo motor power input terminal (U, V, W) directly. Do not let a magnetic contactor, etc. intervene. Drive
ملخص المحتوى في الصفحة رقم 6
(4) Usage CAUTION Provide a emergency stop circuit to ensure that operation can be stopped and power switched off immediately. Any person who is involved in disassembly and repair should be fully competent to do the work. Before resetting an alarm, make sure that the run signal of the servo amplifier is off to prevent an accident. A sudden restart is made if an alarm is reset with the run signal on. Do not modify the equipment. Use a noise filter, etc. to minimize the influence of electromagne
ملخص المحتوى في الصفحة رقم 7
(6) Maintenance, inspection and parts replacement CAUTION With age, the electrolytic capacitor of the drive unit will deteriorate. To prevent a secondary accident due to a fault, it is recommended to replace the electrolytic capacitor every 10 years when used in general environment. Please consult our sales representative. (7) General instruction To illustrate details, the equipment in the diagrams of this Instruction Manual may have been drawn without covers and safety guards. When the equipme
ملخص المحتوى في الصفحة رقم 8
About processing of waste When you discard servo amplifier, a battery (primary battery), and other option articles, please follow the law of each country (area). FOR MAXIMUM SAFETY These products have been manufactured as a general-purpose part for general industries, and have not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the products for special purposes such as nuclear power, electric power, aerospace, medic
ملخص المحتوى في الصفحة رقم 9
COMPLIANCE WITH EC DIRECTIVES 1. WHAT ARE EC DIRECTIVES? The EC directives were issued to standardize the regulations of the EU countries and ensure smooth distribution of safety-guaranteed products. In the EU countries, the machinery directive (effective in January, 1995), EMC directive (effective in January, 1996) and low voltage directive (effective in January, 1997) of the EC directives require that products to be sold should meet their fundamental safety requirements and carry the CE marks
ملخص المحتوى في الصفحة رقم 10
(3) Environment Operate MELSERVO-J2M at or above the contamination level 2 set forth in IEC60664-1. For this purpose, install MELSERVO-J2M in a control box which is protected against water, oil, carbon, dust, dirt, etc. (IP54). (4) Power supply (a) Operate MELSERVO-J2M to meet the requirements of the overvoltage category II set forth in IEC60664-1. For this purpose, a reinforced insulating transformer conforming to the IEC or EN standard should be used in the power input section. (b) When supply
ملخص المحتوى في الصفحة رقم 11
CONFORMANCE WITH UL/C-UL STANDARD The MELSERVO-J2M complies with UL508C. (1) Unit and servo motors used Use the each units and servo motors which comply with the standard model. Drive unit :MR-J2M- DU Interface unit :MR-J2M-P8B Base unit :MR-J2M-BU Servo motor :HC-KFS HC-MFS HC-UFS (2) Installation 3 Install a fan of 100CFM (2.8m /min)air flow 4 in (10.16 cm) above MELSERVO-J2M or provide cooling of at least equivalent capability. (3) Short circuit rating MELSERVO-J2M conforms to the circ
ملخص المحتوى في الصفحة رقم 12
CONTENTS 1. FUNCTIONS AND CONFIGURATION 1- 1 to 1-10 1.1 Overview................................................................................................................................................... 1- 1 1.2 Function block diagram .......................................................................................................................... 1- 2 1.3 Unit standard specifications...............................................................................................
ملخص المحتوى في الصفحة رقم 13
4. OPERATION AND DISPLAY 4- 1 to 4-10 4.1 Normal indication.................................................................................................................................... 4- 1 4.1.1 Display sequence............................................................................................................................... 4- 2 4.1.2 If alarm/warning occurs ................................................................................................................... 4-
ملخص المحتوى في الصفحة رقم 14
9. TROUBLESHOOTING 9- 1 to 9-10 9.1 Alarms and warning list ......................................................................................................................... 9- 1 9.2 Remedies for alarms................................................................................................................................ 9- 3 9.3 Remedies for warnings...........................................................................................................................9-10 10.
ملخص المحتوى في الصفحة رقم 15
Optional Servo Motor Instruction Manual CONTENTS The rough table of contents of the optional MELSERVO Servo Motor Instruction Manual is introduced here for your reference. Note that the contents of the Servo Motor Instruction Manual are not included in this Instruction Manual. 1. INTRODUCTION 2. INSTALLATION 3. CONNECTORS USED FOR SERVO MOTOR WIRING 4. INSPECTION 5. SPECIFICATIONS 6. CHARACTERISTICS 7. OUTLINE DIMENSION DRAWINGS 8. CALCULATION METHODS FOR DESIGNING 4
ملخص المحتوى في الصفحة رقم 16
1. FUNCTIONS AND CONFIGURATION 1. FUNCTIONS AND CONFIGURATION 1.1 Overview The Mitsubishi general-purpose AC servo MELSERVO-J2M series is an AC servo which has realized wiring-saving, energy-saving and space-saving in addition to the high performance and high functions of the MELSERVO-J2-Super series. Connected with a servo system controller or like by a serial bus (SSCNET), the equipment reads position data directly to perform operation. Data from a command unit are used to control the speeds a
ملخص المحتوى في الصفحة رقم 17
1. FUNCTIONS AND CONFIGURATION 1.2 Function block diagram Base unit Interface unit CNP1B L11 I/F Control Power L21 supply Controller or 3-phase FR-BAL CNP3 Servo amplifier NFB MC Position command 200 to I/F Control 230VAC L1 Servo amplifier (Note) or termination L2 connector 1-phase L3 200 to Personal 230VAC RS-232C CNP1A computer Regenerative brake option P Analog monitor D/A (3 channels) N C Drive unit Servo motor Dynamic brake (Earth) U Current V M detector W Overcurrent Current Base amplifie
ملخص المحتوى في الصفحة رقم 18
1. FUNCTIONS AND CONFIGURATION 1.3 Unit standard specifications (1) Base unit Model MR-J2M-BU4 MR-J2M-BU6 MR-J2M-BU8 Number of slots 4 6 8 (Note) Voltage/frequency 3-phase 200 to 230VAC or 1-phase 200 to 230VAC, 50/60Hz Control Permissible voltage fluctuation 1-phase 170 to 253VAC circuit Permissible frequency fluctuation Within 5% power Inrush current 20A (5ms) supply Voltage/frequency 3-phase 200 to 230VAC or 1-phase 200 to 230VAC, 50/60Hz Permissible voltage fluctuation 3-phase 170 to 253VAC
ملخص المحتوى في الصفحة رقم 19
1. FUNCTIONS AND CONFIGURATION 1.4 Function list The following table lists the functions of this servo. For details of the functions, refer to the Reference field. (1) Drive unit (Abbreviation DRU) Function Description Reference High-resolution encoder High-resolution encoder of 131072 pulses/rev is used as a servo motor encoder. Automatically adjusts the gain to optimum value if load applied to the servo motor Auto tuning Chapter 6 shaft varies. Adaptive vibration MELSERVO-J2M detects mechanica
ملخص المحتوى في الصفحة رقم 20
1. FUNCTIONS AND CONFIGURATION 1.5 Model code definition (1) Drive unit (a) Rating plate SON ALM Rating plate MODEL Model MR-J2M-40DU Capacity POWER 400W INPUT DC270V-311V Applicable power supply OUTPUT 170V 0-360Hz 2.3A Rated output current SERIAL N9Z95046 Serial number TC300A***G51 MITSUBISHI ELECTRIC Rating plate (b) Model code MR-J2M- DU Rated output Symbol Capacity of applied servo motor 10 100 20 200 40 400 70 750 (2) Interface unit (a) Rating plate MITSUBISHI AC SERVO Model MODEL MR-J2M-P