ملخص المحتوى في الصفحة رقم 1
Carson Manufacturing Co., Inc.
5451 North Rural Street
Indianapolis, IN 46220
Phone: (888) 577-6877 Fax: (317) 254-2667
www.carsonsirens.com
SC-411RD-10 14
REMOTE SIREN AMPLIFIER
WITH LIGHT CONTROL
YELP PHSR
CARSON
WAIL CYCLE
OFF 1 2 3
STBY RADIO
PA VOL
HORN MANUAL
OUT/DIM
S SC C- -4 41 11 1
S SC C- -4 41 11 1
Elite Force
S1 S2 S3 S4 S5 S6
WARNING: WEAR HEARING PROTECTION REF. OSHA 1910.95
INSTALLATION AND OPERATING
INSTRUCTIONS
Carson is a trademark
ملخص المحتوى في الصفحة رقم 2
Page 2 of 12 Installation and Operating Instructions SC-411RD-10 TABLE OF CONTENTS GENERAL DESCRIPTION ..................................................................................................................................... 3 SPECIFICATIONS .................................................................................................................................................. 3 INSTALLATION.................................................................................
ملخص المحتوى في الصفحة رقم 3
SC-411RD-10 Installation and Operating Instructions Page 3 of 12 GENERAL DESCRIPTION The SC-411RD Remote Light Control/Siren is a premium unit designed for dual 100W speaker use. The pri- mary operating modes are Radio, Cycler, Standby, Yelp, Wail, and Phaser. A Noise Canceling PA Override and push-button Horn Override are available in all modes except Radio. A push-button is provided for toggling between Wail, Yelp, and Phaser tones, and Manual siren control in silent modes. The Phaser
ملخص المحتوى في الصفحة رقم 4
Page 4 of 12 Installation and Operating Instructions SC-411RD-10 INSTALLATION Proper installation of the unit is essential for years of safe, reliable operation. Please read all instruction before installing the unit. Failure to follow these instructions can cause serious damage to the unit or vehicle and may void warranties. SAFETY PRECAUTIONS For the safety of the installer, vehicle operator, passengers and the community please observe the following safety precautions. Failure to fol
ملخص المحتوى في الصفحة رقم 5
L3 SPKR1 L2 SPKRC L1 SPKR2 CUTOUT S6 SIRCTRL S5 LITCTRL S4 BACKLIT S3 RADIO S2 RADIO S1 POWER RGT-A GND LFT-A GND CTR-A VIDEO SC-411RD-10 Installation and Operating Instructions Page 5 of 12 AMPLIFIER WIRING DIAGRAM Aux switch 3 output Aux switch 4 output Aux s
ملخص المحتوى في الصفحة رقم 6
Page 6 of 12 Installation and Operating Instructions SC-411RD-10 OPTION SETTINGS Enter/Exit Program Mode Turn unit on with POWER input. Enter the program mode by pressing and holding OUT/DIM, S1 and S2 for 3 seconds. The unit will beep 3 times and the backlighting will begin flashing to indicate that the unit is in program mode. It will continue to flash until program mode is exited by pressing and holding OUT/DIM for 3 seconds, saving the settings—the unit will emit a long beep. NOTE:
ملخص المحتوى في الصفحة رقم 7
SC-411RD-10 Installation and Operating Instructions Page 7 of 12 Option Set 1 S1 (CUTOUT Input), S2 (SIRCTRL Input), S3 (LITCTRL Input) - These inputs are Press Lever Switch = OFF Shows blinking normally activated by a 12V input (ON). 0↓ On (Default) Cutout Input Active + Press the switch once until it FLASHES to 1↓ S1 Flash Cutout Input Active - change to ground activation. Press the 2 Off Cutout Input Off switch again for OFF to disable. 0↓ On (Default) Siren Control Input Activ
ملخص المحتوى في الصفحة رقم 8
Page 8 of 12 Installation and Operating Instructions SC-411RD-10 OPERATION This unit is designed for easy operation under the stress associated with high-speed pursuit. Most siren func- tions are accessible with one simple motion. Certain operational features or controlled by option settings and/or installation connections. POWER ON/OFF The unit is powered by the ignition switch. SIREN CONTROLS The Rotary Switch selects the primary operating mode of the siren. RADIO - Also known as R
ملخص المحتوى في الصفحة رقم 9
SC-411RD-10 Installation and Operating Instructions Page 9 of 12 YELP PHSR CARSON WAIL CYCLE OFF 1 2 3 STBY RADIO PA VOL HORN MANUAL OUT/DIM S S S SC C C C- - - -4 4 4 41 1 1 11 1 1 1 Elite Force S1 S2 S3 S4 S5 S6 WARNING: WEAR HEARING PROTECTION REF. OSHA 1910.95 LIGHT SYSTEM CONTROLS A 4-position lever switch provides control of primary lighting functions. It also provides automatic activation of the siren. Six additional programmable pushbuttons provided for auxiliary ligh
ملخص المحتوى في الصفحة رقم 10
Page 10 of 12 Installation and Operating Instructions SC-411RD-10 SERVICE This unit is designed to provide years of reliable service under even the worst conditions. Many times there may appear to be a problem with the unit when the true problem is in the speaker(s), controlled devices, or improper installation. The following chart shows typical symptoms and possible causes. A blown siren fuse doesn't necessarily mean that the unit is bad. If a speaker or speaker lead is shorted the int
ملخص المحتوى في الصفحة رقم 11
SC-411RD-10 Installation and Operating Instructions Page 11 of 12 RETURN If you have any questions concerning this or any other Carson product, please contact our Technical Service Department at (888) 577-6877. Many issues can be handled over the phone. We can also be reached via e- mail at service@carson-mfg.com If a product must be returned for any reason, please contact our Technical Service Department to obtain a Returned Merchandise Authorization number (RMA#) before you ship th
ملخص المحتوى في الصفحة رقم 12
Page 12 of 12 Installation and Operating Instructions SC-411RD-10 INSTALLATION CONFIGURATION RECORD Terminal AWG Color Connected to Terminal AWG Color Connected to POS (2) L1 GND (2) L2 POWER L3 RADIO (2) S1 BACKLIT S2 LITCTRL S3 SIRCTRL S4 CUTOUT S5 SPKR1 S6 SPKR2 RGT-A SPKRC LFT-A VIDEO CTR-A S1—S6 Operation: Blank=Default, V=No Video, M=Momentary, 10 or 20=Hold Time Lever / S1 - S6 Switch Association: Bla