ملخص المحتوى في الصفحة رقم 1
®
3 4 4
CS 000/ 000/ 080 HZ
Power Amplifier Owner's Manual
For more information on other great Peavey products, visit your local Peavey dealer or go online to www.peavey.com
ملخص المحتوى في الصفحة رقم 2
Intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. Intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. CAUTION: Risk of electrical shock — DO NOT OPEN! CAUTION: To reduce the risk of electric shock, do not remove cover. No user serviceable parts insi
ملخص المحتوى في الصفحة رقم 3
ملخص المحتوى في الصفحة رقم 4
ملخص المحتوى في الصفحة رقم 5
ملخص المحتوى في الصفحة رقم 6
ملخص المحتوى في الصفحة رقم 7
ENGLISH ® 3 4 4 CS 000/ 000/ 080 HZ Power Amplifiers Congratulations on your purchase of a Peavey CS Series power amplifier! Designed for years of reliable operation, CS Series amplifiers offer the sonic superiority and unsurpassed reliability for which Peavey is famous in a rugged, compact unit. Advanced technologies and extensive protection circuitry allow operation with greater efficiency, even under difficult loads ™ and power conditions. The DDT (Distortion Detection Technique) circuit
ملخص المحتوى في الصفحة رقم 8
ملخص المحتوى في الصفحة رقم 9
Wire Guage Charts Stranded Cable Lgth. Wire Gauge (AWG) Power Loss Power Loss Power Loss (ft.) (8 ohm load) (4 ohm load) (2 ohm load) 5 18 0.81% 1.61% 3.2% 16 0.51 1.02 2.0 14 0.32 0.64 1.28 12 0.20 0.40 0.80 10 0.128 0.25 0.51 10 18 1.61% 3.2% 6.2% 16 1.02 2.0 4.0 14 0.64 1.28 2.5 12 0.40 0.80 1.60 10 0.25 0.51 1.01 40 18 6.2% 11.9% 22% 16 4.0 7.7 14.6 14 2.5 5.0 9.6 12 1.60 3.2 6.2 10 1.01 2.0 4.0 8 0.60 1.20 2.4 18 11.9% 22% 37% 80 16 7.7 14.6 26 14 5.0 9.6 17.8 12 3.2 6.2 11.8 10 2.0 4.0 7.7
ملخص المحتوى في الصفحة رقم 10
Operation Modes Stereo Operation For stereo (dual channel) operation, turn the amplifier OFF and set the mode select switches on the back panel to the out (extended) position. In this mode, both channels operate independently of each other, with their input attenuators controlling their respective levels. Thus, a signal at channel A’s input produces an amplified signal at channel A’s output, while a signal at channel B’s input produces an amplified signal at channel B’s output. Parallel Oper
ملخص المحتوى في الصفحة رقم 11
CAUTION: The on/off switch in this unit does not break both sides of the primary mains. Hazardous energy can be present inside the chassis when the on/off switch is in the off position.
ملخص المحتوى في الصفحة رقم 12
Front Panel 3 1 1 3 2 2 Indicators ® ™ CS Series amplifiers feature three front panel LED indicators per channel: PWR (power), SIG (signal) and DDT (Distortion Detection Technique). These LED indicators inform the user of each channel’s operating status and warn of possible abnormal conditions. PWR LED (1) The Power LED indicates that the channel is operational. It illuminates under normal operation and remains on even when the channel’s DDT circuit is activated. SIG LED (2) The Signal LED il
ملخص المحتوى في الصفحة رقم 13
Protection Features ® The Peavey CS Series incorporates several circuits to protect the amplifier and speakers under virtually any situation. Peavey has made the amplifiers as foolproof as possible by making them immune to short and open circuits, mismatched loads, ™ DC voltage and overheating. If a channel goes into the DDT gain reduction mode, the DDT LED illuminates. The clipping percentage or output power is instantly reduced. When a problem occurs that causes a channel to go into a prote
ملخص المحتوى في الصفحة رقم 14
Protection Features ™ RampUp Signal Control ® Whenever a CS Series amplifier powers up or comes out of a protect mode, the RampUp circuit activates. While the ™ speakers are disconnected, the RampUp circuit fully attenuates the signal and activates the DDT LED. After the output relay closes, the signal slowly and gradually raises up to its set level. The PWR LED will illuminate and the DDT LED will turn off when the signal is no longer attenuated. The RampUp Signal Control circuit has some i
ملخص المحتوى في الصفحة رقم 15
Amplifier Maintenance and User Responsibility A CS Series amplifier requires no routine maintenance and should not need internal adjustment during its lifetime. Your CS Series amplifier is very powerful and can be potentially dangerous to loudspeakers and humans alike. It is your responsibil- ity to read the Important Precautions section and to make sure that the amplifier is installed, wired and operated properly as instructed in this manual. Many loudspeakers can be easily damaged or destroyed
ملخص المحتوى في الصفحة رقم 16
® CS Series 3000/4000/4080 HZ Power Amplifiers SPECIFICATIONS CS 3000 CS 4000 CS 4080 HZ 3,050 watts @ 1 kHz at 4,000 watts @ 1 kHz at 4,080 watts @ 1 kHz at Rated Power Bridged <0.1% T.H.D. @ 4 ohms <0.1% T.H.D. @ 4 ohms <0.1% T.H.D. @ 8 ohms 1,500 watts per channel 2,000 watts per channel N/A Rated Power 2 x 2 ohms @ 1 kHz <0.05% T.H.D. @ 1 kHz <0.1% T.H.D. both channels driven both channels driven 1,025 watts per channel 1,350 watts per channel 2,040 watts per channel Rated Power 2 x
ملخص المحتوى في الصفحة رقم 17
® CS Series SPECIFICATIONS CS 3000 CS 4000 CS 4080 HZ > 15V/us > 15V/us > 15V/us Slew Rate > 500:1 @ 20 Hz - 1 > 500:1 @ 20 Hz - 1 > 500:1 @ 20 Hz - 1 Damping Factor (8 ohms) kHz kHz kHz +5 to - 15 degrees from +5 to - 12 degrees from +5 to - 12 degrees from Phase Response 20 Hz to 20kHz 20 Hz to 20kHz 20 Hz to 20kHz 1.6 volts +/- 3% for 1 1.84 volts +/- 3% for 1 2.25 volts +/- 3% for 1 Input Sensitivity kHz. 4 ohms rated power, kHz. 4 ohms rated power, kHz. 4 ohms rated power 1.37 volts
ملخص المحتوى في الصفحة رقم 18
DEUTSCH ® 3 4 4 CS 000/ 000/ 080 HZ Endstufen Herzlichen Glückwunsch zum Kauf einer Endstufe der CS Series von Peavey! Die Verstärker der CS Series wurden für einen zuverlässigen Betrieb und lange Lebensdauer entwickelt. In einem robusten, kompakten Gerät bieten sie die überragende Schallleistung und die unübertroffene Zuverlässigkeit, für die Peavey bekannt ist. Fortschrittliche Technologien und umfassende Schutzschaltungen ermöglichen einen effizienteren Betrieb auch bei problematischen L
ملخص المحتوى في الصفحة رقم 19
ملخص المحتوى في الصفحة رقم 20
Kabelstärkentabellen Stranded Cable Lgth. Wire Gauge (AWG) Power Loss Power Loss Power Loss (ft.) (8 ohm load) (4 ohm load) (2 ohm load) 5 18 0.81% 1.61% 3.2% 16 0.51 1.02 2.0 14 0.32 0.64 1.28 12 0.20 0.40 0.80 10 0.128 0.25 0.51 10 18 1.61% 3.2% 6.2% 16 1.02 2.0 4.0 14 0.64 1.28 2.5 12 0.40 0.80 1.60 10 0.25 0.51 1.01 40 18 6.2% 11.9% 22% 16 4.0 7.7 14.6 14 2.5 5.0 9.6 12 1.60 3.2 6.2 10 1.01 2.0 4.0 8 0.60 1.20 2.4 18 11.9% 22% 37% 80 16 7.7 14.6 26 14 5.0 9.6 17.8 12 3.2 6.2 11.8 10 2.0 4.0