ملخص المحتوى في الصفحة رقم 1
(Ver 1.04)
Technical Manual (Ver 1.03)
Color Camera Module
• NTSC Model
Model No.
VCC-MD800 (×36, Day/Night type)
VCC-MD700 (×36, Color type)
VCC-MD600 (×30, Day/Night type)
VCC-MD500 (×30, Color type)
VCC-MD400 (×22, Day/Night type)
VCC-MD300 (×22, Color type)
• PAL Model
VCC-MD800P (×36, Day/Night type)
VCC-MD700P (×36, Color type)
VCC-MD600P (×30, Day/Night type)
VCC-MD500P (×30, Color type)
VCC-MD400P (×22, Day/Night type)
VCC-MD300P (×22, Color type)
VCC-MD500/MD500P VCC-MD400/MD400P
VCC-MD
ملخص المحتوى في الصفحة رقم 2
Contents Parts Names and Dimensions ........ 2 Function Descriptions ................... 27 [1] Zoom Control .......................................................27 Connection ....................................... 4 [2] Focus Control ...................................................... 28 [1] Connection of the Interface Board and Camera Unit ..........................................................4 [3] White Balance Control ......................................... 28 [2] Interface Bo
ملخص المحتوى في الصفحة رقم 3
Parts Names and Dimensions ■ VCC-MD800/700/600/500 Series CN204 terminal Lens Dimensions ■ Note: The numbers within the brackets refer to the dimensions of the VCC-MD700 and MD800 models. 3-M2 SCREW 25.1 29 4-M2 SCREW TAP TAP 7.1 18 (2.2) 50 3.53 84 3-M2 SCREW 4-M2 SCREW TAP 7.1 18 TAP 25.1 29 − 2 − 60 38.6)* 12 8 40.5 12 8 16 16
ملخص المحتوى في الصفحة رقم 4
Parts Names and Dimensions ■ VCC-MD400/MD300 Series CN204 terminal: MD300 CN301 terminal: MD400 Lens Dimensions ■ Note: The numbers within the brackets refer to the dimensions of the VCC-MD400 model. 24 29 4-M2 50 12.5 77 24 29 4-M2 − 3 − 60 29.7)* 32.1 16 16
ملخص المحتوى في الصفحة رقم 5
Connection [1] Connection of the Interface Board and Camera Unit Connect the camera unit and the interface board using the FFC (flexible flat cable). Connect the various terminals of the interface board using the necessary cables. FFC CN005 S0001 B A CN004 CN003 CN001 CN002 GND V PULSE DC12V GND ■ V PULSE [2] Interface Board Specifications Input the signal of the following external tuning into the V PULSE terminal (CN004). Connector Terminal Name Details Input a signal that satisfies the requi
ملخص المحتوى في الصفحة رقم 6
Input-Output Terminal Descriptions [1] Input-Output Terminal Layout and Specifications Power Supply: DC 6-12V Pin Number Signal Name Function I/O Signal Specifications CAMERA 1 RD: RS-232C Communication Line Low: Max 0.8V (Receiving) High: Min 2.0V 1 RD 2 SD: RS-232C Communication Line Low: Max 0.1V 2 SD (Transmitting) High: Min 4.4V 3 GND 3 RD&SD GND Communication GND — 4 DC IN DC Power Supply Input DC +6 – 12V 4 DC N (+6 – 12V) 5 DC IN GND Power Supply GND — FFC 5 GND (DC) 6 VIDEO OUT 75Ω C
ملخص المحتوى في الصفحة رقم 7
Communications Protocol ⁃ Checksum Format [1] Communications Format The communication unit is a 4 (min)-24 (max) byte 0 0/1 0/1 0/1 0/1 0/1 0/1 0/1 packet. Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 ・Communications Speed: (MSB) (LSB) 2400, 4800, 9600, 19200, 38400 ・Bit 0-6: Take the value that sets the lower 7 bits of 9600 bps the values added from the header to the (DEFAULT MD800 – 500) * MD400 and MD300 cannot connect at 38400bps. checksum to 0. DEFAULT is 19200bps. ・Bit 7: Fix
ملخص المحتوى في الصفحة رقم 8
Communications Protocol 3 During Query Command (ACK) [2] Communications Flow Note: Start the transmission of the next data after ◦ Transmission Transmission Source Destination (Unit) confirming the response command. The maximum transmission interval of the ◦ Header various byte data is 500 [msec]. If this is exceeded, a communication error is detected Message 1 in the camera unit, the receiving data is deleted, and data from the header is waiting Message 2 to be received again. Further
ملخص المحتوى في الصفحة رقم 9
Communications Protocol Model: VCC-MD800/700/600/500 [3] Command List for MD800-500 Message System All Initial A0 01 0A CS FF Initialization of Unadjusted EEPROM Values (Set to Factory Defaults) All Menu Initial A0 01 0B CS FF Initialization of All Menu Settings Lens Initial A0 01 0C CS FF Detection of initial lens position Reset A0 01 0D CS FF Restarting camera (Saves the setting value) Menu Initial A0 01 0E CS FF Initialization of menu settings other than privacy ma
ملخص المحتوى في الصفحة رقم 10
Communications Protocol Model: VCC-MD800/700/600/500 Message Backlight BLC OFF A0 06 00 CS FF Backlight compensation OFF Multi BLC ON A0 06 01 CS FF Backlight compensation multifractionated evaluative metering mode (Backlight compensates after measuring the light of the entire screen.) Multi BLC Weight - A0 06 04 00 CS FF Sensitivity settings during Multi BLC BLC is easier to determine with a larger value (Initial value: 7) Multi BLC Weight + A0 06 04 01 CS FF Multi BLC Weight
ملخص المحتوى في الصفحة رقم 11
Communications Protocol Model: VCC-MD800/700/600/500 Message Sync Sync INT A0 09 00 CS FF Internal synchronization mode Sync L-L A0 09 01 CS FF Power supply synchronization mode L-L Phase + A0 09 0B CS FF Synchronous phase settings for power source synchronization L-L Phase - A0 09 0C CS FF L-L Phase Preset A0 09 0F CS FF Returns synchronous phase settings for power source synchronization to factory defaults (Initial value: 0) L-L Phase Direct A0 09 13 0p 0q 0r CS FF pqr: Sync
ملخص المحتوى في الصفحة رقم 12
Communications Protocol Model: VCC-MD800/700/600/500 Message OSD Zoom Ratio A0 14 00 0p CS FF p: Zoom magnification display Zoom Ratio Position A0 14 01 p 0q CS FF Zoom magnification display position p: x-position (0-19) q: y-position (0-11) (Initial value: x: 19 y: 11) Direction A0 14 02 0p CS FF p: Orientation / angle information display (1: ON/0: OFF) (Note 4) Direction Position A0 14 03 0p 0q CS FF Positioning of the orientation / angle information display p: x-position (0-11) q: y-pos
ملخص المحتوى في الصفحة رقم 13
Communications Protocol Model: VCC-MD800/700/600/500 − 12 − [4] Command List (Query) for MD800-500 Message Query Command Response Command Zoom Tele/Wide Speed 80 02 08 CS FF C0 02 08 0p CS FF Configured Tele/Wide Speed 1: speed1, 2: speed2, 3: speed3, 4: speed4 Direct 80 02 09 CS FF C0 02 09 0p 0q 0r CS FF Current Zoom Lens Position Direct Position 0:Wide 2263:Tele Digital Zoom Tele Limiter 80 02 18 CS FF C0 02 18 0p CS FF Current Digital Zoom Limit V-Reso.UP OFF/ON 80 02 1F CS
ملخص المحتوى في الصفحة رقم 14
Communications Protocol Model: VCC-MD800/700/600/500 − 13 − Message Query Command Response Command Sync L-L Phase Direct 80 09 13 CS FF C0 09 13 0p 0q 0r CS FF Power Source Synchronous Set Value Direct 0-524(NTSC) / 0-624(PAL) AGC Max Gain at AGC 80 0A 09 CS FF C0 0A 09 0p CS FF AGC MAX Gain Set Value p: 0:LOW, 1: NORM, 2: MID, 3: HIGH (COLOR) (D/N camera set value when in COLOR) p: 0:LOW, 1: NORM, 2: MID, 3: HIGH Max Gain at AGC(BW) 80 0A 0A CS FF C0 0A 0A 0p CS FF A
ملخص المحتوى في الصفحة رقم 15
Communications Protocol Model: VCC-MD800/700/600/500 − 14 − Message Query Command Response Command DAY/NIGHT D/N LEVEL 80 28 05 CS FF C0 28 05 0p CS FF Color/Black and White Switch Level 0: LOW, 1: MID, 2: HIGH, 3: ADJ Set Value D/N ADJ DIRECT 80 28 06 CS FF C0 28 06 0p CS FF Color Black and White Switch Level 0-6 (C->B/W) Manual Set Value D/N ADJ DIRECT (B/ 80 28 07 CS FF C0 28 07 0p CS FF Black and White Color Switch Level 0-6 W->C) Manual Set Value D/N FOCUS
ملخص المحتوى في الصفحة رقم 16
Communications Protocol Model: VCC-MD400/300 [5] Command List for MD400 and 300 Message System CAMERA TYPE Unit A0 01 01 00 CS FF CAMERA TYPE Dome A0 01 01 01 CS FF Sanyo Dome Camera ID CAMERA TYPE Zoom A0 01 01 02 CS FF Sanyo Dome Camera ID All Initial A0 01 0A CS FF Initialization of Unadjusted EEPROM Values (Set to Factory Defaults) All Menu Initial A0 01 0B CS FF Initialization of All Menu Settings Lens Initial A0 01 0C CS FF Detection of initial lens position Reset A0 0
ملخص المحتوى في الصفحة رقم 17
Communications Protocol Model: VCC-MD400/300 Message Backlight BLC OFF A0 06 00 CS FF Backlight compensation OFF Multi BLC ON A0 06 01 CS FF Backlight compensation multifractionated evaluative metering mode (Backlight compensates after measuring the light of the entire screen.) Multi BLC Weight - A0 06 04 00 CS FF Sensitivity settings during Multi BLC BLC is easier to determine with a larger value (Initial value: 7) Multi BLC Weight + A0 06 04 01 CS FF Multi BLC Weight Preset
ملخص المحتوى في الصفحة رقم 18
Communications Protocol Model: VCC-MD400/300 Message Camera OFF A0 15 00 CS FF Camera ID display ID ON A0 15 01 CS FF ID SET (ASCII code) A0 15 09 p q r s t Camera ID settings (Note 5) u v w x y z g h i j k CS FF ID X-Position + A0 15 0B CS FF Setting the positioning of the Camera ID display (horizontal) ID X-Position - A0 15 0C CS FF ID Y-Position + A0 15 10 CS FF Setting the positioning of the Camera ID display (vertical) ID Y-Position - A0 15 11 CS FF AGC COLOR MAX Gain *1 A0 0A 00 0p CS
ملخص المحتوى في الصفحة رقم 19
Communications Protocol Model: VCC-MD400/300 Message DAY/ D/N COLOR *1 A0 28 00 CS FF Color Mode NIGHT D/N BLACK/WHITE *1 A0 28 01 CS FF Black and White Mode D/N AUTO *1 A0 28 02 CS FF Color/Black and White Auto Switch Mode D/N BURST OFF *1 A0 28 03 CS FF Burst Settings ON/OFF D/N BURST ON *1 A0 28 04 CS FF D/N LEVEL *1 A0 28 05 0p CS FF Color/Black and White Switch Level Settings (0: LOW, 1: MID, 2: HIGH, 3: ADJ) Switch Level LOW: Dark-HIGH: Bright ADJ: Manual Settings D/N
ملخص المحتوى في الصفحة رقم 20
Communications Protocol Model: VCC-MD400/300 − 19 − [6] Command List (Query) for MD400 and 300 Message Query Command Response Command Zoom Tele/Wide Speed 80 02 08 CS FF C0 02 08 0p CS FF Configured Tele/Wide Speed 1: speed1, 2: speed2, 3: speed3, 4: speed4 Direct 80 02 09 CS FF C0 02 09 0p 0q 0r CS FF Current Zoom Lens Position Direct Position D/N Model 0:Wide 2069:Tele Color Model 0:Wide 2488:Tele Focus Far/Near Speed 80 03 08 CS FF C0 03 08 0p CS FF Configured Far