ملخص المحتوى في الصفحة رقم 1
®
EH3508/EH3512/
EH3515 Series
Environmental
Enclosure
Installation/
Operation Manual
C478M-L (11/03)
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • DataFAX (1-559) 292-0435
ملخص المحتوى في الصفحة رقم 2
IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by qualified service personnel and con- form to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclo- sure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4. After repl
ملخص المحتوى في الصفحة رقم 3
EH3512-3 Same as EH3512 except unit is supplied with 230 VAC heater, defroster, and blower, 22 watts. EH3512-3HD Same as EH3512 except unit is supplied with 230VAC heater and defroster, 13 watts. EH3515 Enclosure, indoor/outdoor, 15.75-inch (40.00 cm) lower body length. (CE) EH3515-1 Same as EH3515 except unit is supplied with 120 VAC heater, defroster, and blower, 27 watts. EH3515-1HD Same as EH3515 except unit is supplied with 120 VAC heater and defroster, 23 watts. EH3515-2 Same as EH3515 exc
ملخص المحتوى في الصفحة رقم 4
7. Pull the video and power cables through the glands or conduit on the bottom of the en- closure. Refer to Tables A and B to determine the size of power wire to use. Refer to Table C for the type of video coaxial cable to use. 8. Attach the cables to the camera. 9. If the enclosure has accessories that require power, connect the power to pins 1 and 2 on the PC Board (refer to Figures 1, 2, and 3 for information about accessory wiring). Connect ground to pin 3 if required. You can connect the ca
ملخص المحتوى في الصفحة رقم 5
120 VAC MODEL 24 VAC MODEL INPUT, AC HIGH INPUT, AC HIGH INPUT, AC LOW (NEUTRAL) INPUT, AC LOW (NEUTRAL) 1 1 GROUND GROUND 2 2 3 3 RED RED 4 4 DIODE DEFROSTER BLOWER DEFROSTER BLOWER BLK BLK 5 5 BRIDGE 6 6 CAP 7 7 8 8 9 9 FRONT HEATER FRONT HEATER 10 10 REAR HEATER REAR HEATER 230 VAC MODEL INPUT, AC HIGH INPUT, AC LOW (NEUTRAL) 1 GROUND 2 RESISTOR 3 4 DEFROSTER 120 VAC BLOWER NOTE: BLOWER APPLIES 5 6 TO -1/-2/-3 MODELS ONLY. 7 8 9 FRONT HEATER 10 REAR HEATER Figure 3. EH3515-1/-1HD/-2/-2HD/-3
ملخص المحتوى في الصفحة رقم 6
Table A. Enclosure Accessory Wiring Distances (Continued) Model Number Input Voltage Accessories Power Consumption Cable Size Cable Distance EH3515-2 24 VAC Heater 25 watts 20 AWG 128 ft (39 m) at 60 Hz Defroster 18 AWG 204 ft (62 m) Blower 16 AWG 323 ft (98 m) 14 AWG 516 ft (157 m) EH3515-3 230 VAC Heater 32 watts 20 AWG 21 ft (6 m) at 50 Hz Defroster 18 AWG 34 ft (10 m) Blower* 16 AWG 55 ft (16 m) 14 AWG 88 ft (26 m) EH3515-1HD 120 VAC Heater 23 watts 20 AWG 21 ft (6 m) at 60 Hz Defroster 18
ملخص المحتوى في الصفحة رقم 7
OPERATION If your enclosure has a thermostatically controlled heater, the thermostat is set to turn on at 50°F (10°C) and to turn off at 80°F (27°C). If your enclosure has a blower and/or defroster, they operate continuously. MAINTENANCE Regularly scheduled maintenance prolongs the operational life and appearance of the equipment. Clean the window regularly with a soft cloth using a mild, nonabrasive detergent and water to maintain picture clarity. SERVICE MANUAL If you need to repair the camera
ملخص المحتوى في الصفحة رقم 8
5.14 (13.05) A 3.88 (9.86) B C 2.00 EH3508 EH3512 EH3515 (5.08) A 10.75 (27.30) 14.75 (37.47) 17.75 (45.09) B 8.75 (22.22) 12.75 (32.38) 15.75 (40.00) C1 7.32 (18.59) 1.25 (28.57) 14.25 (36.20) NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES Figure 4. EH3508, EH3512, EH3515 Dimension Drawing WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or If a warranty repair is required, the Dealer must c