INSTALLATION/OPERATION
DF5S Series
Fixed Mount Dome
C1475M-C (9/08)
ملخص المحتوى في الصفحة رقم 2
ملخص المحتوى في الصفحة رقم 3
Important Safety Instructions Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4. After replacemen
ملخص المحتوى في الصفحة رقم 4
Description The DF5S Series fixed mount dome is designed for indoor use where there is limited space above the ceiling. The dome can be installed in hard ceilings or standard 2 x 2 ft (61 x 61 cm) suspended ceilings. The back box requires only 2.75 inches (7 cm) of room. When there is not enough room to install the DF5S Series back box in the ceiling, the back box can be attached to the surface of the ceiling. A special trim ring, the DF5S-SMKIT, hides the back box. The entire assembly (back b
ملخص المحتوى في الصفحة رقم 5
Hard Ceiling Installation 1. Locate the center point of the mounting location. Drill a hole in the ceiling using a 3/32-inch drill. Insert the compass tool into the hole. Use a pencil and the compass tool to draw a circle on the ceiling. Carefully cut out the circle. Figure 1. Preparing the Ceiling C1475M-C (9/08) 5
ملخص المحتوى في الصفحة رقم 6
2. Attach a conduit fitting (not supplied), safety chain bracket, and lock nut (not supplied). Install a safety chain/cable (not supplied) that will support up to 16 pounds (7.3 kg). Install one end of the safety chain/cable to the safety chain bracket and the other end to a support structure in the ceiling. 3. Prepare the wiring for camera and lens power; refer to Table A and Table B on page 8 for wiring distances. Pull the wiring into the back box through the conduit fitting. 4. Compress t
ملخص المحتوى في الصفحة رقم 7
Suspended Ceiling Installation 1. Remove the ceiling tile from the ceiling. Insert the compass tool (supplied) into the center of the tile. (If necessary, use a 3/32-inch bit to drill a hole.) NOTE: The ceiling tile cannot be thinner than 0.50-inch (1.27 cm) or thicker than 1.75 inches (4.45 cm). 2. Draw a circle on the tile using the compass tool and a pencil. Carefully cut out the circle. Figure 3. Preparing the Ceiling Tile 3. Attach a conduit fitting (not supplied), safety chain bracket, a
ملخص المحتوى في الصفحة رقم 8
Table A. Video Coaxial Wiring Distances Cable Type* Maximum Distance RG59/U 750 ft (299 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) *Cable requirements: 75-ohm impedance All-copper center conductor All-copper braide shield with 95% braid coverage Table B shows the recommended maximum distances for 24 VAC with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) Table B. 24 VAC Wiring Distances Wire Gauge Total VA 20 18 16 14 12
ملخص المحتوى في الصفحة رقم 9
Lower Dome Installation 1. Snap the clip, located on the end of the trim ring leash, into the hole on the lip of the back box. 2. Line up the snaps on the trim ring with the mounting screws on the back box. Snap the trim ring into the plastic snap washers on the mounting screws. Figure 6. Installing the Lower Dome Maintenance Clean the acrylic dome as needed. Be careful not to scratch the surfaces of the dome. Exterior surface: Clean the dome’s exterior surface with a nonabrasive cleaning clot
ملخص المحتوى في الصفحة رقم 10
Specifications MECHANICAL Construction Back Box Aluminum Mounting Bracket Steel Lower Dome Acrylic Trim Ring Eggshell white molded plastic, UL94V0 GENERAL Environment Indoor Operating Temperature 32° to 122°F (0° to 50°C) Weight (without camera) 1.75 lb (0.80 kg) CAMERA Maximum Camera and Lens Size 5.00" L x 2.75" W x 2.75" H (12.70 x 6.99 x 6.99 cm) (Design and product specifications subject to change without notice.) IN-CEILING DOME 7.25 (18.41) 6.60 (16.76) 2.75 (6.99) 3.25 (8.26) 5.90 (14.9
ملخص المحتوى في الصفحة رقم 11
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in Pelco assumes no risk and shall be subject to no liability for damages or loss material or workmanship for a period of one year after the date of shipment. resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of Exceptions to this warranty are as noted below
ملخص المحتوى في الصفحة رقم 12
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: (800) 289-9100 Fax: (800) 289-9150 International Tel: +1 (559) 292-1981 Fax: +1 (559) 348-1120 www.pelco.com ISO9001 Australia Finland France Germany Italy Macau The Netherlands Russia Singapore | | | | | | | | South Africa Spain Sweden United Arab Emirates United Kingdom United States | | | | |