ملخص المحتوى في الصفحة رقم 1
K
L
E
T
I
R
S
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,SLR SLC SLD - LINEAR P/N: 227968 X11 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
SLR - SLC - SLD
Slide Gate Operator
Installation Guide
CM
C US
Operator models contained in this manual
conform to UL325 standard for use in
Class I, II, III, and IV applications
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp
ملخص المحتوى في الصفحة رقم 2
Table of Contents Pre-installation Information . . . . . . . . . . . . . . . . . . . . . . . .1 . . .Ad . .v . anced Contr . . . . oller Programming . . . . . . . . . . . . . . . . . . . . . . . . . . 13 . Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . Enter . . . ing Adv . . anced Programming Mode . . . . . . . . . . . . . . .1 .3 . . . . . Always Check the Gate’s Action . . . . . . . . . . . . . . . . . . . .1 . . . . . .Maxim . . um Run Time .
ملخص المحتوى في الصفحة رقم 3
Pre-installation Information Safety Information and Warnings THE FOLLOWING FORMATS ARE USED FOR SAFETY NOTES Before You Begin... IN THESE INSTRUCTIONS. Before unpacking, inspect the carton for exterior damage . If CAUTION you find damage, advise the delivery carrier of a potential This type of warning note is used to claim . Inspect your package carefully . You can check your indicate the possibility of damage to the accessory box parts with the enclosed packing slip for your gate or ga
ملخص المحتوى في الصفحة رقم 4
MODEL SLR POWER WIRING Wiring Specifications MAXIMUM DISTANCE (FEET) VOLTS & HP WIRE GAUGE Refer to the following steps for details on power and SINGLE DUAL 316 158 12 accessory wiring for the operator . 502 251 10 115 VOLTS 800 400 8 WARNING 1/2-HP 1272 636 6 ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE AND 2022 1011 4 THE OPERATOR MUST BE MADE BY A LICENSED ELECTRICIAN 764 382 12 AND MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL 1218 609 10 230 VOLTS CODES. 1936 968 8 1/2-HP 3076
ملخص المحتوى في الصفحة رقم 5
Mounting Pad Installation WARNING The operator is intended for installation only on gates used for The gate operator mounts bolted to a custom poured vehicles. Pedestrians must be supplied with a separate access concrete mounting pad . The pad supports the operator and opening. The pedestrian access opening shall be designed to prevents it from moving during operation . promote pedestrian usage. Locate the gate such that persons An optional post mount kit is also available (P/N 2120-483)
ملخص المحتوى في الصفحة رقم 6
Gate Bracket and Chain Assembly 8 ✓ NOTE: The item numbers shown in these illustrations are for reference only. For the actual part numbers, refer 9 to the parts lists in the rear of this manual. Assemble a gate bracket (1) to the front edge of the gate, using two U-bolts (2), and mounting hardware (3) . Before tightening down completely, be sure the bracket is parallel to the gate . Tighten the U-bolt hardware the rest of the way, 5 then screw the square head bolts (4) into the threaded
ملخص المحتوى في الصفحة رقم 7
GEAR Operator Preparation REDUCER Vent Plug Installation In order to keep gear oil from spilling out during shipping, REMOVE THE SOLID PLUG gear reducers used in this gate operator has either a solid WITH AN ALLEN plug, or a sealed vent plug, installed at the factory . WRENCH For operators with a solid plug, replace the solid plug with the vent plug provided (see Figure 5) . With the vent plug installed, remove the vent plug’s breather pin to allow the gear box to vent (see Figure 5) . INSTA
ملخص المحتوى في الصفحة رقم 8
Operator Setup (Continued) LEFT-HAND INSTALLATION RIGHT-HAND INSTALLATION CLOSE LIMIT OPEN LIMIT OPEN LIMITCLOSE LIMIT Limit Nuts Rough Adjustment The limit nuts are not preset at the factory and must be adjusted for the length of the gate in each installation . The limit switches are activated by two threaded nylon rotary RIGHT-HAND limit nuts which are attached to a threaded limit shaft driven LIMIT OPEN by a chain and sprockets from the main drive shaft (see SHAFT DIRECTION LIMIT Figure 8
ملخص المحتوى في الصفحة رقم 9
Controller Features WHIP ANTENNA ANTENNA CONNECTOR OPERATION AND POWER OPERATION PROGRAMMING INDICATORS BUTTONS INDICATORS DISPLAY PROGRAMMING SOLAR BUTTONS PANEL TERMINALS INPUT POWER MOTOR TERMINALS BOARD COVER ACCESSORY POWER BATTERY TERMINALS TERMINALS RESET BUTTON TERMINALS PLUG-IN LOOP PRIMARY/ DETECTOR SECONDARY CONNECTORS COMM LINK TERMINALS SINGLE INPUT TERMINALS FIRE DEPT INPUT TERMINALS OPEN INPUT TERMINALS 3-BUTTON SHADOW/RESET STATION TERMINALS AUXILIARY OPEN AND CLOSE REVERSE LOOP
ملخص المحتوى في الصفحة رقم 10
Indicator Descriptions INDICATOR DEFINITION INDICATION WHEN LIT INDICATION WHEN LIT DURING NORMAL OPERATION DURING PROGRAMMING OPERATION PROGRAMMING 24 VOLT INPUT LOW VOLTAGE AC POWER IS PRESENT POWER 24 VOLT DC LOW VOLTAGE DC POWER IS PRESENT ACCY POWER OPEN SIGNAL PRESENT FROM THE INTERNAL OPEN RECEIVER OR AN EXTERNAL DEVICE CONNECTED TO THE OPEN INPUT TERMINAL CLOSE SIGNAL IS PRESENT FROM A DEVICE CLOSE CONNECTED TO THE CLOSE INPUT TERMINAL STOP INPUT TERMINAL IS OPEN AND STOP NOT CONN
ملخص المحتوى في الصفحة رقم 11
Terminal Descriptions TERMINAL GROUP FUNCTION AC N FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR 24 VOLT INPUT 24 VDC FROM CONTINUOUS DUTY DC SUPPLY. AC DC - ACCESSORY POWER PROVIDES 24 VOLT DC POWER FOR ACCESSORIES. (.5A MAX) DC + RESET RESET BUTTON FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON. COMMON C B COMM LINK FOR 3-WIRE NETWORK CONNECTION TO SECOND OPERATOR IN DUAL GATE INSTALLATIONS. A COMMON CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES SINGLE BUTTON
ملخص المحتوى في الصفحة رقم 12
Operator Accessory Connections 3-BUTTON STATION PHOTOEYE FOR REVERSE TELEPHONE ENTRY KEYPAD PHOTOEYE FOR CLOSE OBSTRUCTION KEYSWITCH FIRE ACCESS SWITCH SOLENOID LOCK EXTERNAL POWER PHOTOEYE FOR OPEN OBSTRUCTION SINGLE-CHANNEL RADIO RECEIVER MAGLOCK GATE EDGE SENSOR FOR REVERSE TWO-CHANNEL RADIO RECEIVER WARNING STROBE OR AUDIBLE SOUNDER CHANNEL #1 WIRELESS GATE EDGE SENSOR OPEN/CLOSE MGT TRANSMITTER Figure 11. Operator Accessory Connections SLR • SLC • SLD Slide Gate Operator Installation Guide
ملخص المحتوى في الصفحة رقم 13
Basic Controller Programming Programming Overview PROGRAM The Controller can be programmed with various options for the operator. INDICATOR The programming fields are defined as “functions” that have “options”. To DOWN AND UP make setup easier for the installer, the Controller’s programming is divided into two groups: basic and advanced. The basic programming group PRESS DOWN AND UP PROGRAM INDICATOR contains the functions commonly used in most slide gate installations. BUTTONS TOGETHER WILL
ملخص المحتوى في الصفحة رقم 14
Basic Controller Programming (Cont.) FUNCTION OPTIONS Run Alarm and Pre-start Alarm RUN ALARM OFF "RP" The factory default is Run Alarm on and a 3-second Pre-start Alarm. The PRE-START ALARM OFF operator’s beeper will sound 3 seconds before the operator starts. The options are: RUN ALARM ON PRESS UP OR PRE-START ALARM OFF DOWN TO CYCLE • Run Alarm Off and Pre-start Alarm Off THROUGH OPTIONS • Run Alarm On and Pre-start Alarm Off RUN ALARM ON PRESS ENTER TO • Run Alarm On and Pre-start Alarm
ملخص المحتوى في الصفحة رقم 15
Advanced Controller Programming FUNCTION OPTIONS Entering Advanced Programming Mode ADVANCED PROGRAMMING FUNCTIONS "AD" To access and program the Advanced Programming functions, for each WILL NOT BE DISPLAYED programming session, Advanced Programming must be enabled. ADVANCED PROGRAMMING OPTIONS After exiting programming, the Advanced Programming functions WILL BE DISPLAYED will be available on the programming display during the next programming session unless the operator has run 50 or more
ملخص المحتوى في الصفحة رقم 16
Advanced Controller Programming (Cont.) FUNCTION OPTIONS Auxiliary Relay Mode AUXILIARY RELAY DISABLED "AR" The Auxiliary Relay has normally open and normally closed contacts. The factory setting disables the Auxiliary Relay. The relay can be set for: AUXILIARY RELAY USED FOR MAGLOCK CONTROL • Maglock: The relay will energize during any pending or actual gate PRESS UP OR DOWN TO CYCLE motion (open only), to deactivate a magnetic or solenoid gate lock. AUXILIARY RELAY USED FOR THROUGH OPTIONS
ملخص المحتوى في الصفحة رقم 17
Advanced Controller Programming (Cont.) FUNCTION OPTIONS Soft Start/Stop Duration SOFT START DISABLED "SS" This function is only used with DC slide gate Model SLD. This function causes the operator to start and stop the DC motor slowly SET SOFT START DURATION TIME reducing gate wear and tear (at the full open or closed positions only). FROM 1 TO 10 SECONDS The factory default sets the Soft Start/Stop Duration to 3 seconds. The Soft Start/Stop Duration can be set from 1 to 10 seconds. PRESS U
ملخص المحتوى في الصفحة رقم 18
Advanced Controller Programming (Cont.) FUNCTION OPTIONS Radio Enable "RA" INTERNAL RADIO RECEIVER DISABLED ® The Controller contains a built-in MegaCode radio receiver to allow activation from up to 40 access control transmitters and two Model MGT (gate edge) transmitters. The factory default enables the internal radio INTERNAL RADIO RECEIVER ENABLED receiver. Alternately, the internal receiver can be disabled. PRESS UP OR Antenna Installation DOWN TO CYCLE THROUGH OPTIONS The Controller is
ملخص المحتوى في الصفحة رقم 19
Loop Layout Illustration SLR • SLC • SLD Slide Gate Operator Installation Guide - 17 - 227968 Revision X13 2-3-09 2" MAX. TWIST WIRE FROM END OF LOOPS BACK TO OPERATOR AT LEAST SIX TIMES PER FOOT 3/8" LOOP SEALANT 2" MULTIPLE TURNS REFER TO LOOP INSTALLATION NOTES FOR DETAILS USE RELIEF CUTS SEPARATE PEDESTRIAN AT CORNERS GATE REQUIRED 7 FEET MINIMUM DISTANCE FROM GATE
ملخص المحتوى في الصفحة رقم 20
Safety Edge Layout Illustration #1 SLR • SLC • SLD Slide Gate Operator Installation Guide - 18 - 227968 Revision X13 2-3-09 THIS DRAWING IS INTENDED TO DRAW ATTENTION TO POSSIBLE LOCATIONS FOR THE INSTALLATION OF CONTACT OR NON-CONTACT OBSTRUCTION SENSING DEVICES. OTHER AREAS OF ENTRAPMENT MAY EXIST DEPENDING ON EACH SPECIFIC INSTALLATION. SEE NOTE REVERSING EDGE ITEM #2 ASSY CLOSEUP SEE NOTE ITEM #4 4 FOR CLARITY, FENCE AND PEDESTRIAN GATE NOT SHOWN 2 SEE NOTE 3 ITEM #1 SEE NOTE ITEM #1 ITEM