ملخص المحتوى في الصفحة رقم 1
L
I
S
O WNER ’ S M ANU AL
GP-SW050
Residential Duty Swing Gate Operator
With Inherent UPS Battery Back-up System
TWO 12VDC, U1, 230A BATTERIES ARE REQUIRED BUT NOT INCLUDED.
DO NOT Install This Operator Without Safety Edges and Photo Beams!
APPROPRIATE ENTRY/EXIT DEVICES WILL BE REQUIRED - SEE YOUR DEALER.
This product meets and exceeds the requirements of UL 325 gate operator safety standards.
US
For more information on GTO’s full line of automatic gate openers and access controls visit our web
ملخص المحتوى في الصفحة رقم 2
The GP-SW050 automatic gate operators are intended for use with vehicular swing gates. The operators can be used in Class I, II, III, and IV applications. VEHICULAR GA TE OPER A TOR class categories c lass i: Residential Vehicular Gate Operator – A v ehicular ga t e oper a t or (or sy st em) in t ended f or use in a home of one -t o -f our single family dw elling , or a gar age or par k ing ar ea associa t ed ther ewith. c lass ii: Commercial/General Access Vehicula
ملخص المحتوى في الصفحة رقم 3
t able of c ontents Gate Operator Class Categories ...................................................................................... I nside C o v er M etr ic C on v ersion Char t .......................................................................................................................... I nside C o v er S af et y I nstruc tions f or the GP -SW050 S wing G a t e Oper a t ors ....................................................1 I mpor tan t S af et y I nstruc tions f or the S
ملخص المحتوى في الصفحة رقم 4
Important Safety Instructions SAFETY INSTRUCTIONS FOR ThE GP-SW050 SWING GATE OPERATORS Because automatic gate operators produce high levels of force, all system designers, installers, and consumers ha v e an obliga tion t o k no w the pot en tial hazar ds associa t ed with impr oper ly desig ned , installed , or main tained gate operator systems. Keep in mind that the gate operator is just one component of the total gate operating system. Each c omponen t must w or k in uniso
ملخص المحتوى في الصفحة رقم 5
Important Safety Instructions ImPORtant Safety InStRUctIOnS For the Installer WARNING–To reduce the risk of injury or death: I. Before Installation 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. V er ify this oper a t or is pr oper f or the t ype and siz e of ga t e , and its fr equenc y of use . 3. M ake sur e tha t the ga t e has been pr oper ly installed and swing fr eely in both dir ec tions . R epair or r eplac e all w or n or damaged ga t e har dw ar e pr ior t o
ملخص المحتوى في الصفحة رقم 6
Important Safety Instructions ImPORtant Safety InStRUctIOnS Specific to Secondary Means of Protection Against Entrapment A s specified b y Under wr it ers Labor a t or ies I nc . UL 325 (30A.1.1), aut oma tic ga t e oper a t ors shall ha v e provisions for, or be supplied with, at least one independent primary and one independent secondary means to protect against entrapment. GTO gate operators utilize Type A, an inherent entrapment sensing system, as the primary type of entrapm
ملخص المحتوى في الصفحة رقم 7
Important Safety Instructions important s afety instructions f or the C onsumer/End U ser WARNING: To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Distr ibut e and discuss c opies of the IMPORTANT SAFETY INSTRUCTIONS manual with all persons authorized to use your gate. SAVE THESE INSTRUCTIONS. 3. A lw a y s keep people and objec ts a w a y fr om the ga t e and its ar ea of tr a v el . NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Y
ملخص المحتوى في الصفحة رقم 8
Important Safety Instructions required s afety Precautions for g ates Entrapment Protection GTO’s internal obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily injury. For this reason, safety devices such as safety edges and photo beams MUST be installed. Furthermore, a walk-through gate must be installed if pedestrian traffic is expected near the gate. We recommend the GTO Bulldog Pedestrian Gate Lock
ملخص المحتوى في الصفحة رقم 9
L I S Important Safety Instructions Warning l abels These warning signs and labels should be found at the locations specified below. If any of them are missing, immediately contact your installer for replacements. ! WARNING Moving Gate Can Cause Injury Or Death 1. KEEP CLEAR! Gate may move at any time. 2. Do not allow children to operate gate or play in gate area. 3. This gate is for vehicles only. Pedestrians must use a separate entrance. Warning signs (2) to be installed
ملخص المحتوى في الصفحة رقم 10
t echnical specifications Motor • Brushless DC mot or 24VDC 300 w a tts • ½ Horsepo w er • M aximum mot or cur r en t 20A mp • 2500 RP M • Open and close time f or 90° opening is appr o xima t ely 15 sec onds g ear reducer • A luminum C ased 1200:1, siz e 40/63, c ompound , w or m r educ er with ball bear ings . • P er manen tly lubr ica t ed with syn thetic gear oil – oil specifica tions 5w -30, M obil 1 r ec ommended Power • 120 v ac @60 H z with inher en t 24 v dc ba tt er y bac
ملخص المحتوى في الصفحة رقم 11
Parts identification Fully Assembled Operator Operator Chassis 12½ in 13 in (31.8 cm) (33 cm) 17 in (42 cm) 27 in 23¾ in (69 cm) (60.3 cm) 19¾ in 24 in 33 in (61 cm) (50.2 cm) (84 cm) TO BASE 18 in 6 in (46 cm) 14½ in 12½ in (15.2 cm) (36.8 cm) (31.8 cm) 15 in (38 cm) 3 in NOTE: GTO receiver (RB709U), (7.6 cm) batteries (12vdc, U1, 230A minimum) not included. Must order separately. Owner’s Manual GTO/PRO GP-SW050 AC Powered Swing Gate Operators WARNING Gate Bracket Gate Warning Signs Owner
ملخص المحتوى في الصفحة رقم 12
installing the g ate o perator This unit must only be installed by an experienced technician. Preparation of the Gate Before installing the GTO swing gate operator, make sure: • the ga t e is pr oper ly installed . • the ga t e is plumb , lev el , and mo v es fr eely . • the ga t e does not bind or dr ag on the g r ound . Overview of a Single Gate Operator Installation T he diag r am belo w is an e xample of a single swing ga t e installa tion with r equir ed saf et y f ea tur es . T he op
ملخص المحتوى في الصفحة رقم 13
GROUND LEVEL Using the Mounting t emplate The mounting template (see insert) is desig ned t o simplify moun ting the oper a t or . I t pr o vides the installer with the pr oper loca tions f or running po w er and ac c essor y wir ing c onduits . T he t empla t e is also mar ked with the c or r ec t distanc e bet w een the oper a t or moun ting holes and sho w s the installer ho w t o position the oper a t or f or the c or r ec t clear anc e bet
ملخص المحتوى في الصفحة رقم 14
Gate closed position Hinge centerline Gate open position Drill 3/8” x 3” deep Gate post 6 places. Use 3/8” wedge type anchors. 2½” 3” 18½“ From Hinge Centerline 7“ From Hinge Centerline Output Shaft 10” Concrete pad 16” x 16”. Consult local building codes for depth below ground. Absolute minimum depth 30” below ground level. 4 5/8” 6 3/8” 11” Mounting t emplate (NO T T O SC ALE) 11
ملخص المحتوى في الصفحة رقم 15
removing the o perator Housing B ef or e y ou can gain ac c ess t o the oper a t or fr ame and its moun ting holes , the housing will ha v e t o be removed from the operator. 1. R emo v e the (2) 3/8” allen bolts and (2) m8 w ashers fr om the oper a t or housing (this har dw ar e is located on each side of the housing). 2. Lift the housing off the operator and set it aside. Allen Bolts with 5mm key Washers Mounting the o perator 1. Lif t the oper a t or and alig n its m
ملخص المحتوى في الصفحة رقم 16
c onnecting Power to the o perator 1. T ur n the br eaker po w er swit ch off bef or e c onnec ting A C po w er . Ha v e a lic ensed elec tr ician run 115 V ac wir ing in t o the F ield W ir ing C onnec tion C ompar tmen t . T he 115 V ac line will po w er the ga t e oper a t or sy st em. T he cir cuit must be pr ot ec t ed with a 15 A main disc onnec t br eaker (not provided). NOTE: Power and wiring connections MUST be performed by a licensed electrician in accordan
ملخص المحتوى في الصفحة رقم 17
g ate a rm c onnection o verview Right Mounted Arm Center point of gate hinge Center point to center of gate bracket pin of gate hinge (approximately) 50” Column Closed Gate Range of Arm Movement 5°-10° 160°-175° Housing Pivot point of operator Center point of gate hinge Round Column Opened Gate Closed Gate CAUTION: DO NOT STAND Housing IN THIS AREA Pivot point 2 ft. square area of operator Opened Gate IMPORTANT: Be sure the operator housing will not be hit by a fully open gate and that
ملخص المحتوى في الصفحة رقم 18
ON 1 2 3 4 c onnecting the g ate a rm to the g ate Key Bolts Reducer and Arm Output Shaft Washers Fig. 1 Fig. 2 1. Install the key into the output shaft. (Fig. 1) OPTIONS 2. Fit the end of the reducer arm onto the output shaft as sho wn and OFF ON MODE 1 tighten the bolts. (Fig. 2) OFF ON MODE 2 <<< >>> OPEN DIR. 3. Turn the power on. DELAY SIMUL SLV OPN MASTER SLAVE DUAL MODE 4. Set DIP switch 1 to designate the operator arm as left or right (Fig. 3) SECURE LOW BATT SAFE
ملخص المحتوى في الصفحة رقم 19
ON 1 2 3 4 ACC. POWER DUAL CABLE RELAY OUTPUTS c ontrol Board Description 2 1 BLDC SPEED CONTROL EXIT SHADOW SAFETY LIMIT SENSORS ALARM GTO LOOP DETECTORS 3 STATUS AT OPEN +12Vdc LIMIT + ACC. PWR. PRISON 4 12VDC MODE COM - 300ma DUAL LINK DUAL LINK 5 LINK COM 14 20 LOCK N.C. 13 LOCK LOCK COM 6 LOCK N.O. 12 RUNNING DIAG. RUN 1 PORT 7 RUN 2 11 OPTIONS CLOSED CLOSED 1 OFF ON MODE 1 19 8 OFF ON MODE 2 CLOSED 2 <<< >>> OPEN DIR. DELAY SIMUL SLV OPN MASTER SL
ملخص المحتوى في الصفحة رقم 20
s etting the limits CAUTION: Be extremely careful not to stand in the path of the gate arm while setting limits. OPEN LIMIT SETTING: 1. T ur n on oper a t or po w er . 2. Press and release the OPEN button on the board and be prepared to press the STOP button when the ga t e r eached the desir ed open position/limit . 3. The JOG buttons can be used to bring the gate to the precise open position. The JOG buttons will slo wly run the ga t e when pr essed and st op the g