ملخص المحتوى في الصفحة رقم 1
QUICK START GUIDE
Cisco ASR 1004 Router
1 Documentation and Resources
2 Prepare for Installation
3 Rack-Mount the Router
4 Connect the Router to the Network
5 Start the System
6 Configure the Router
7 After Installation
ملخص المحتوى في الصفحة رقم 2
1 Documentation and Resources Documentation for the Cisco 1000 Series Aggregation Services Routers documentation is online with the exception of the regulatory compliance and safety documentation and the Cisco 1000 Series Aggregation Services Routers documentation flyer. For detailed hardware installation instructions, refer to the online Cisco Series 1000 Aggregation Services Routers Hardware Installation and Initial Configuration Guide. Refer to the following documentation for installation
ملخص المحتوى في الصفحة رقم 3
2 Prepare for Installation This section contains information about tools and parts, warnings, site preparation information, and information for rack-mount and equipment shelf or tabletop installation. Warning Only trained and qualified personnel should install, replace, or service this equipment. Statement 1030 Before beginning this router installation, read the Regulatory Compliance and Safety Information for the Cisco 1000 Series Aggregation Services Routers document. Site Preparation and U
ملخص المحتوى في الصفحة رقم 4
Prepare for Rack-Mount Installation Before you begin the rack-mounting tasks: Decide whether or not you want to front- mount or rear-mount the chassis Decide whether or not you want to attach cable-management brackets to your chassis. Note If you install cable management brackets, make certain that you use the specified rack-mount ear holes as stated in the procedure. Decide if a two-post or four-post rack-mount will be used 3 Rack-Mount the Router This section provides information for
ملخص المحتوى في الصفحة رقم 5
1 1 0 Step 6 To install the Cisco ASR 1004 Router in an equipment rack, see “Four-Post Rack Installation” section on page 6 or “Two-Post Rack Installation” section on page 8. Note If you install cable management brackets, make certain that the chassis is mounted in the equipment rack first. Attach the Rack-Mount Brackets—Chassis Rear-Mounted To install the rack-mount on a Cisco ASR 1004 Router for a rear rack-mount configuration, follow these steps: Step 1 Locate the threaded holes in the rear
ملخص المحتوى في الصفحة رقم 6
Four-Post Rack Installation This section describes the types of racks used for rack-mounting the chassis. Figure 3 Installing the Cisco ASR 1004 Router in a Four-Post Rack 1 2 3 4 1 Equipment rack rear rail 3 Front rack-mount bracket and ear holes 2 Chassis rear rack-mount bracket and ear holes 4 Equipment rack front rail Note Because the rack-mount brackets support the weight of the entire chassis, be sure to use all screws to fasten the two rack-mount brackets on the chassis to the rack post
ملخص المحتوى في الصفحة رقم 7
Step 5 Lift the chassis into position between the rack posts (requires two people). Step 6 Align the mounting bracket holes with the rack post holes and attach the chassis to the rack. At this point, if there is a third person, then that person can insert the screws while the other two people hold that chassis in place, unless the chassis is resting on a shelf. Step 7 Position the chassis until the rack-mounting flanges are flush against the mounting rails on the rack. Note To allow space to a
ملخص المحتوى في الصفحة رقم 8
Two-Post Rack Installation The Cisco ASR 1004 Router can be installed in a two-post rack, either 19 inch or 23 inch. Note Inner clearance (the width between the inner sides of the two posts or rails) must be at least 19 inches (48.26 cm). The height of the chassis is 1.73 inches (4.39 cm). Airflow through the chassis is from front to back. Figure 4 Installing a Cisco ASR 1004 Router in a Two-Post Rack 1 2 1 Rack-mount bracket ear and holes 2 Rack equipment rail Caution If you are using a two-po
ملخص المحتوى في الصفحة رقم 9
Step 4 Hold the chassis in position against the mounting rails and follow these steps: a. Insert the bottom screw into the third hole up from the bottom of the rack mount ear and use a hand-held screwdriver to tighten the screw to the rack rail (see Figure 4). Tip Insert the bottom screw first and then the second screw at the top of the chassis diagonally from the bottom screw. This helps secure the chassis in place while you insert the other screws. b. Insert the top screw into the third hole
ملخص المحتوى في الصفحة رقم 10
Figure 5 Attaching the Cable-Management Bracket to the Cisco ASR 1004 Router 1 3 2 1 Cable-management bracket screws Chassis front rack-mount bracket ear 1 3 2 Cable-management bracket Step 3 Using the bottom rack-mount ear hole, insert the screw through cable-management bracket and into the chassis rack-mount (see Figure 5). Figure 4 shows the cable-management brackets attached to the chassis in a rack. Step 4 Using a Phillips screwdriver and the cable management screw, thread and tighten the
ملخص المحتوى في الصفحة رقم 11
Figure 6 Chassis Ground Lug Location on the Cisco ASR 1004 Router 1 1 Chassis ground connector on the Cisco ASR 1004 Router Use the following procedure to attach the grounding lug to the chassis ground connector on your chassis: Step 1 Use the wire stripper to strip one end of the AWG #6 wire approximately 0.75 inches (19.05 mm). Step 2 Insert the AWG #6 wire into the wire receptacle on the grounding lug. Step 3 Use the crimping tool to carefully crimp the wire receptacle around the wire; this
ملخص المحتوى في الصفحة رقم 12
Step 5 Locate the chassis ground connector on the side of your chassis. Step 6 Insert the two screws through the holes in the grounding lug. Step 7 Use the Number 2 Phillips screwdriver to carefully tighten the screws until the grounding lug is held firmly to the chassis. Do not overtighten the screws. Step 8 Connect the opposite end of the grounding wire to the appropriate grounding point at your site to ensure an adequate chassis ground. This completes the procedure for attaching a chassis
ملخص المحتوى في الصفحة رقم 13
Step 2 After you establish normal router operation, you can disconnect the terminal. Note For console and auxiliary port pinouts, see Appendix A in the Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide. Management Ethernet Port Cable Connection Before you can use the console interface on the router using a terminal or PC, you must perform the following steps: Step 1 Configure your terminal emulation software with the following settings: 9
ملخص المحتوى في الصفحة رقم 14
Step 3 Insert an Ethernet RJ-45 cable into the MGMT ETHERNET port. Step 4 Insert the other end of the RJ-45 cable to your management device or network. Step 5 Configure to a fixed speed through the command line interface (CLI) commands. Connect the Shared Port Adapter Cables The instructions for connecting the cables for the shared port adapter installed in the Cisco ASR 1004 Router are contained in the Cisco ASR 1000 Series Aggregation Services Routers SPA and SIP Hardware Installation Guide.
ملخص المحتوى في الصفحة رقم 15
Step 3 Insert the AC power cable into the power supply inlet. Step 4 Plug the power supply cable into the power source. Step 5 The power supply LEDs light when power is supplied to the router. Figure 10 Cisco ASR 1004 Router AC Power Supply 1 2 OUTPUT INPUT FAN FAIL OK OK 100V-240V~ 12A-5A ALARMS 50-60Hz 60V 1A MAX OUTPUT INPUT FAN FAIL OK OK 100V-240V~ 12A-5A ALARMS 50-60Hz 60V 1A MAX 5 4 3 1 AC power supply Standby switch 4 AC power supply fan 2 AC power supply LEDs 5 AC power inlet 3 DB-25 Al
ملخص المحتوى في الصفحة رقم 16
Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024 Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Statement 1028 Warning This product relies on the building’s instal
ملخص المحتوى في الصفحة رقم 17
Figure 10 shows the DC power supply for the Cisco ASR 1004 Router. DC Power Supply for the Cisco ASR 1004 Router 1 2 OUTPUT INPUT FAN FAIL OK OK 60V 1A MAX OUTPUT INPUT FAN FAIL OK OK 60V 1A MAX 7 6 5 4 3 DC power supply terminal block and plastic cover DC power supply earth ground symbol 1 5 2 DC power supply LEDs 6 DC power supply On (I)/ Off (O) DB-25 alarm connector DC power supply handle 3 7 4 DC power supply fan The Cisco ASR1004 has two of the same type power supplies in power supply Slot
ملخص المحتوى في الصفحة رقم 18
Figure 11 DC Power Supply Grounding Stud Location and Connection on the Cisco ASR 1004 Router 4 3 2 1 DC power supply grounding stud DC power supply chassis grounding stud location 1 3 2 Grounding stud screws 4 Earth ground symbol Step 1 Make certain that the chassis ground is connected before you begin installing the DC power supply. Step 2 Locate the ground stud on the DC power supply for the GND connection which must be installed first and replace the ground stud components in the following
ملخص المحتوى في الصفحة رقم 19
Figure 12 Cisco ASR 1004 Router DC Power Supply Terminal Block 2 1 5 4 3 Ground lug and positive lead wire Washer 1 4 2 Terminal block and positive stud 5 Kepnut screw Earth grounding symbol 3 Caution Before you continue to install the terminal block wires, stop and perform Step 3 to prevent any contact with metal lead on the ground wire. Step 3 You must wrap the positive and negative cables with sleeving. Take each ground wire and cover the area from the lug to the wire with heavy shrink sle
ملخص المحتوى في الصفحة رقم 20
Step 8 Connect the other ends of the terminal block cables to the site ground connection. Move the circuit-breaker switch to the On position (|). This completes the procedure for connecting DC-input power. Your installation is complete. Proceed to the “Start the System” section on page 14 to start the router. Note After powering off the router, wait a minimum of 30 seconds before powering it on again. Verifying Power Supply Operation Follow this procedure to verify power supply is operating co