INSTALLATION INSTRUCTIONS
DROP-IN ELECTRIC RANGE
Table of Contents
RANGE SAFETY .............................................................................1
INSTALLATION REQUIREMENTS................................................2
Tools and Parts............................................................................2
Location Requirements................................................................2
Electrical Requirements...............................................................
ملخص المحتوى في الصفحة رقم 2
WARNING Tip Over Hazard A child or adult can tip the range and be killed. Install anti-tip bracket to floor or wall per installation instructions. Slide range back so rear range foot is engaged in the slot of the anti-tip bracket. Re-engage anti-tip bracket if range is moved. Do not operate range without anti-tip bracket installed and engaged. Failure to follow these instructions can result in death or serious burns to children and adults. To verify the anti-tip bracket is installed and engaged:
ملخص المحتوى في الصفحة رقم 3
Mobile Home - Additional Installation Requirements Cabinet Dimensions The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 Cabinet opening dimensions shown are for 25" (64 cm) (formerly the Federal Standard for Mobile Home Construction countertop depth, 24" (61 cm) base cabinet depth and and Safety, Title 24, HUD Part 280). When such standard is not 36" (91.4 cm) countertop height. applicable, the Standard for Manufa
ملخص المحتوى في الصفحة رقم 4
■ A circuit breaker is recommended. Electrical Requirements ■ Flexible conduit from appliance should be connected directly to the junction box. If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that ■ Do not cut the conduit. The length of conduit provided is for the ground path and wire gauge are in accordance with local serviceability of the range. codes. ■ A UL listed or CSA approved conduit connector must be Check with
ملخص المحتوى في الصفحة رقم 5
5. Drill two ¹⁄₈" (3.0 mm) holes that correspond to the bracket holes of the determined mounting method. See the following Install Anti-Tip Bracket illustrations. Floor Mounting Wall Mounting WARNING A B A B Tip Over Hazard A child or adult can tip the range and be killed. Install anti-tip bracket to floor or wall per installation instructions. Slide range back so rear range foot is engaged in the slot of the anti-tip bracket. Re-engage anti-tip bracket if range is moved. A. #12 x 1⁵⁄₈" scre
ملخص المحتوى في الصفحة رقم 6
Electrical Connection 4-Wire Cable from Home Power Supply WARNING IMPORTANT: Use the 4-wire cable from home power supply where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes, recreational vehicles, and new construction. A B Electrical Shock Hazard E Disconnect power before servicing. F Use 8 gauge solid copper wire. G Electrically ground oven. Failure to follow these instructions can result in death, fire, or electrical shock. H
ملخص المحتوى في الصفحة رقم 7
1. Connect the 2 black wires (C) together using a UL listed wire connector. Install Lower Trim 2. Connect the 2 white wires (D) and the green (or bare) ground wire (of the range cable) using a UL listed wire connector. 3. Connect the 2 red wires (G) together using a UL listed wire connector. 4. Install junction box cover. Verify Anti-Tip Bracket Is Installed and Engaged 1. Verify that the anti-tip bracket is installed and engaged by completing the following steps. 2. If the lower trim is al
ملخص المحتوى في الصفحة رقم 8
Moving the Range If removing the range is necessary for cleaning or maintenance: WARNING WARNING Tip Over Hazard Electrical Shock Hazard A child or adult can tip the range and be killed. Disconnect power before servicing. Install anti-tip bracket to floor or wall per installation Replace all parts and panels before operating. instructions. Failure to do so can result in death or electrical shock. Slide range back so rear range foot is engaged in the slot of the anti-tip bracket. 1. Disconnect