ملخص المحتوى في الصفحة رقم 1
AX400 / AE 500 H First Edition
Owner’s Manual
Thank you for purchasing our receiver
For proper use of this receiver, please read this manual thoroughly.
Keep this manual in a safe place for future reference.
WARNING
l Do not use any batteries other than size AA Alkaline or manganese batteries. Using different batteries could
cause fire, electric shock or failure.
l Do not place consumed batteries in a fire. They could explode, causing fire or burns.
l Do not install or remove batteries while you
ملخص المحتوى في الصفحة رقم 2
l Never disassemble the receiver. Never touch the receiver ’ s core. l It is adjusted for optimum performance. l Avoid hot places and locations exposed to direct sunlight. l Avoid extremely cold places. l Avoid exposing the receiver to excessive vibrations and dusty places. l Applicable batteries are either AA-size manganese or alkaline batteries. Never use any other batteries. l This receiver require 2.2 to 3.5 volts DC. l This receiver is capable of receiving AM, FM Narrow Band (Amateur Rad
ملخص المحتوى في الصفحة رقم 3
by the POWER key. Please take out the batteries and replace them! Adjusting the Volume To increase the volume, turn the VOL knob clockwise. (Illust. 8) To decrease the volume, turn the VOL knob counterclockwise. (Illust. 7) CAUTION l Set the volume to an acceptable loudness level. Be sure to decrease the volume level before switching from built-in speaker to earphones. Adjusting the Squelch When a signal is not being received, a noise is emitted. The Squelch adjustment eliminates this n
ملخص المحتوى في الصفحة رقم 4
(Illust. 13-2) Hold down FUNC key and press POWER key. (A high pitched beep is emitted). Release the keys and confirm if the original state is displayed in the display. (Illust. 13-3) Resetting the All Settings (All Reset) With following procedure, your receiver is set at factory ’ s original setting. Use this function only when it is necessary such event as CPU is locked up. All channel memories will be lost and rewritten to factory settings. Refer to the table below for detail factory set
ملخص المحتوى في الصفحة رقم 5
l Pressing this key while the FUNC key is pressed activates the light. 2 MODE Key l Enters numeric „ 2“ . l Pressing this key while the FUNC key is pressed changes the reception Mode from AM to FM or to FM Wide. 3 SEARCH Key l Enters numeric „ 3“ . l Pressing this key while the FUNC key is pressed initiates the Search stand-by state. 4 MY/ Key l Enters numeric „ 4“ . l Pressing this key while the FUNC key is pressed changes the Set Mode function stored in the My Key. l Pressing this key while th
ملخص المحتوى في الصفحة رقم 6
Confirm the display. If M is displayed, press CLEAR PROGRAM key. (When ‘ M ’ is displayed, you are in the Channel Memory Mode. ) Use rotary selector to change the frequency up or down to confirm you are in FREQ Mode. Changing the Frequency There are three methods for changing the frequency, 1) using rotary elector, 2) using the 5 key or ENT key while the FUNC key is pressed, and 3) using the numeric keys. Before changing the frequency, confirm you are in FREQ Mode by pressing CLEAR PROGRAM ke
ملخص المحتوى في الصفحة رقم 7
How to Recall the Channel Memory [1] The frequencies that have previously been programmed into channel memories can be recalled by using following method. Using the selector Hold down FUNC key and press 7 FREQ/CH key to set to the channel memory mode. (Illust. 18) Turning the Selector in the clockwise direction to increase the channel memory address number. Turning counterclockwise to decrease the channel memory address number. Using the 5(Up) or ENT (Down) key Hold down FUNC key and press 7
ملخص المحتوى في الصفحة رقم 8
4. To complete this procedure, press CLEAR PROGRAM key. Note: l All the contents of channel memories are cleared during All Reset procedure even when this function is activated. l This function does not apply to protect Search Pass Channel Memories. Erasing Channel Memories by Block at a Time Channel Memory can be cleared by blocks. A block of channel memory is made up of 100 channel memory addresses grouped consecutively. The relationship between the block number and the channel memory addres
ملخص المحتوى في الصفحة رقم 9
Search and Scan Function Search and Scan Function l In the Expanded Mode, in order to search for the desired frequencies, Search and Scan functions are provided. A Dual Watch function is also provided where a specific frequency can be received alternately with a frequency stored in channel memory. l The Search function has three different types. All Search ( ‘ 39) Searches the entire band. One Touch Search ( ‘ 39) Searches between two frequencies written to Search Band Channel Memory. Program Se
ملخص المحتوى في الصفحة رقم 10
Using a One Touch Search In this mode, you are able to set upper and lower limits of frequencies to be searched between. The 10 sets frequencies (20 frequencies) are already preprogrammed in 20 Search Band Channel Memories Set the unit to the FREQ Mode by pressing CLEAR PROGRAM key. Hold down FUNC key and press 3 SEARCH key. (SEArCH is displayed.) Press corresponding numeric key to select a desired search band listed below. The unit starts searching the specified band immediately. (Illust.2
ملخص المحتوى في الصفحة رقم 11
Erasing the Search Band Channel Memory The frequencies entered in Search Band Channel Memory can be erased. 1. Set the unit to the Channel Memory Mode by pressing 7 FREQ./CH while FUNC is pressed until ‘ M ’ appears on the display. 2. Turn the selector to select the Channel Memory address of the search band that you wish to erase. (Illust. 30-1) 3. Hold down FUNC key and press CLEAR PROGRAM key. (CLr is displayed.) (Illust. 30-2) 4. Hold down FUNC key and press CLEAR PROGRAM key once again.
ملخص المحتوى في الصفحة رقم 12
appears on the display. 2. Hold down FUNC key and press 7 FREQ/CH key once again. 3. Select the channel memory address to be erased by using the selector or numeric keys. (Illust. 33-1) 4. Hold down FUNC key and press 9 L/OUT key. ( „ CLr“ is displayed.) (Illust. 33-2) 5. Hold down FUNC key and press 9 L/OUT key once again to confirm deletion. ( A high pitched beep is emitted and the frequency is erased from search pass channel memory.) 6. To complete the procedure, press CLEAR PROGRAM key. Not
ملخص المحتوى في الصفحة رقم 13
Scanning A Block of Channels (Block Scan) You can scan through only specified block of channels. One block consists of 100 channel memory addresses. ( ‘ 34) Hold down FUNC key and press 8 SCAN key. (All channel scan starts.) Enter the block number to be scanned using the numeric key. (Illust. 37) To scan another block, enter the block number using the numeric key. To end, press CLEAR PROGRAM key. l When the block number is specified while in Memory Scan Memory, only specified channels within
ملخص المحتوى في الصفحة رقم 14
TO USE YOUR RECEIVER MORE EFFECTIVELY In order to use your receiver more effectively, the unit enables you to change various settings. All these functions are programmed in SET mode initiated by pressing FUNC and 0 SET key simultaneously. Changing the Frequency Step When the frequency is changed either manually or by searching, it increases or descreses in accordance with the frequency step assigned or specified. In the initial state (when shipped from the factory), the frequency step is set au
ملخص المحتوى في الصفحة رقم 15
To complete the setting, press CLEAR PROGRAM key. Changing Light Operation The light stays on for 5 seconds after the Light key is released. The Light operation can be changed so that it remains on until the Light key is pressed again. Hold down FUNC key and press 0 SET Key. Turn the selector to change Set menu to display „ nor LAmP“ . (Illust. 43) Hold down FUNC key and turn the selector to change the display from „ nor“ to „ tGL“ . To complete the setting, press CLEAR PROGRAM key. To tu
ملخص المحتوى في الصفحة رقم 16
To activate the programmed SET MODE, simply hold down FUNC key and press 4 MY key. The value of the settings are changed by repeating the action. When Reset or All Reset are performed, the contents of this key return to the memorized frequency step. Using the Selector in Key Lock When Key Lock is activated, all the keys except POWER/SQL OFF/SQL/VOLUME are locked. This function additionally allows rotary selector to effective even when Key Lock is activated. Hold down FUNC key and press 0 SET ke
ملخص المحتوى في الصفحة رقم 17
Changing the Frequency to MHz Digit (Fast Step) In order to change the frequency rapidly, this receiver is equipped with FAST STEP function. This is activated by turning the rotary selector while FUNC key is pressed. Initially at the factory, a digit of 1MHz is set for this mode therefore the frequencies change at the digit of 1MHz by activating FAST STEP. The digit of frequency may be reprogrammed of your preference. To change the digit of FAST STEP, Hold down FUNC key and press 0 SET key. Tu
ملخص المحتوى في الصفحة رقم 18
The channel memory is not stored. There are no vacant channel Memory addresses. Does not scan/ search. Squelch is off. Not able to scan Channel Memories The frequencies are not stored or only one frequency is stored. Specifications General Frequency range 0.500MHz - 1299.999MHz Speaker impedance 8 ohms Antenna impedance 50 ohms Antenna connector BNC Frequency Step 1kHz, 5kHz, 6.25kHz, 9kHz, 10kHz, 12.5kHz, 15kHz, 20kHz, 25kHz, 30kHz, 50kHz, 100kHz, AUTO Number of Channel Memory Channel Memor