CONTENTS SAFETY PRECAUTIONS .......................................... 1 ADJUSTING THE DIRECTION OF AIR CIRCULATION ..... 10 FEATURES AND FUNCTIONS ................................. 2 SWING OPERATION ............................................ 11 NAME OF PARTS ...................................................... 3 CLEANING AND CARE ........................................ 12 PREPARATION .......................................................... 5 SELECTING THE REMOTE CONTROL UNIT OPERATION ..
ملخص المحتوى في الصفحة رقم 3
FEATURES AND FUNCTIONS AUTOMATIC OPERATION REMOVABLE INTAKE FILTER COOLING MODEL The indoor unit’s INTAKE FILTER can be removed for easy Merely press the START/STOP button, and the unit will cleaning and maintenance. begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room. MILDEW-RESISTANT FILTER HEAT & COOL MODEL (REVERSE CYCLE) The INTAKE FILTER has been treated to resist mildew growth, Merely pre
ملخص المحتوى في الصفحة رقم 4
NAME OF PARTS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Fig. 1 C 1 2 Fig. 2 4 3 B 0 76 5 8 Fig. 3 A 9 D Fig. 5 D Fig. 4 E Fig. 6 Fig. 8 Fig. 7 En-3
ملخص المحتوى في الصفحة رقم 5
Fig. 1 Indoor Unit Fig. 6 Remote Control Unit 1 Operating Control Panel (Fig. 2) F SLEEP button 2 MANUAL AUTO button G MASTER CONTROL button H SET TEMP./SET TIME buttons ( ) 3 Remote Control Signal Receiver I Signal Transmitter 4 Indicator Lamps (Fig. 3) J TIMER button 5 OPERATION Indicator Lamp K FAN CONTROL button (green ...... COOL, DRY, FAN) L START/STOP button (red .......... *HEAT) M AIR FLOW DIRECTION 6 TIMER Indicator Lamp (yellow) VERTICAL SET button 7 SWING Indicator Lamp (orange) N
ملخص المحتوى في الصفحة رقم 6
PREPARATION CAUTION! Load Batteries (R03/LR03 ××× 2) ×× Take care to prevent infants from accidentally swallowing batteries. Press and slide the battery compartment lid on the re- When not using the remote control unit 1 verse side to open it. for an extended period, remove the batteries to avoid possible leakage and Slide in the direction of the arrow while pressing the mark. damage to the unit. If leaking battery fluid comes in contact Insert batteries. with your skin, eyes, or mouth,
ملخص المحتوى في الصفحة رقم 7
OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Select Mode Operation Press the START/STOP button (Fig. 6 L). 1 The indoor unit’s OPERATION indicator lamp (green or red) (Fig. 3 5) will light. The air conditioner will start operating. Press the MASTER CONTROL button (Fig. 6 G) to se- 2 lect the desired mode. Each time the button is pressed, the mode will change in the following order: ss AUTO COOL s DRY t t *HEAT FAN About three secon
ملخص المحتوى في الصفحة رقم 8
OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). About Mode Operation AUTO: COOLING MODEL When the room temperature is 4 °F higher Cooling Operation than the set temperature, the mode will switch between Cooling and Drying. Dry Operation During Drying mode operation, FAN set- Thermostat control ting is switched to LOW gentle cooling effect, and the room fan may stop rotat- ing temporarily . 4 °F If the mode automatically selected by
ملخص المحتوى في الصفحة رقم 9
TIMER OPERATION Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 5). To Use the ON timer or OFF timer To Cancel the Timer Press the START/STOP button (Fig. 6 L) Use the TIMER button to select “TIMER 1 RESET”. (if the unit is already operating, proceed to step 2). The air conditioner will return to normal The indoor unit’s OPERATION indicator lamp (green or red) (Fig. 3 5) will light. operation. Press the TIMER button (Fig. 6 J) to
ملخص المحتوى في الصفحة رقم 10
SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP timer To Cancel the Timer: While the air conditioner is operating or stopped, press the Use the TIMER button to select “TIMER SLEEP button (Fig. 6 F). RESET”. The air conditioner will return to normal Both the indoor unit’s OPERATION indicator lamp (green or red) (Fig. 3 5) and the operation. TIMER indicator lamp (yellow) (Fig. 3 6) will
ملخص المحتوى في الصفحة رقم 11
ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Vertical (up-down) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION VERTICAL SET button. Horizontal (right-left) direction of airflow is adjusted by pressing the remote control unit’s AIR FLOW DIRECTION HORIZONTAL SET button. DANGER! Vertical Air Direction Adjustment Never place fingers or foreign objects inside Pres
ملخص المحتوى في الصفحة رقم 12
SWING OPERATION Begin air conditioner operation before performing this procedure. To select Vertical airflow SWING Operation Press the AIR FLOW DIRECTION VERTICAL SWING button (Fig. 6 N). The SWING indicator lamp (VERTICAL SWING) (Fig. 3 7) will light. In this mode, the UP/DOWN air direction flaps will swing automatically to direct the air flow both up and down. To Stop Vertical airflow SWING Operation Press the AIR FLOW DIRECTION VERTICAL SWING button (Fig. 6 N) once again. The SWING indicator
ملخص المحتوى في الصفحة رقم 13
CLEANING AND CARE Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply. CAUTION! Turn off the electrical breaker. Be sure the intake filter (Fig. 4 9) is installed securely. When removing and replacing the intake filters, be sure not to touch the heat exchanger, as personal injury may result. Cleaning the Intake Filters 1. Remove the intake filters. 3. Install the intake filters. 1 Place fingers in grids on the front of the intake filters Hang the
ملخص المحتوى في الصفحة رقم 14
SELECTING THE REMOTE CONTROL UNIT SIGNAL CODE When two or more air conditioners are installed in a room and the remote control unit is operating an air conditioner other than the one you wish to set, change the signal code of the remote control unit to operate only the air conditioner you wish to set (four selections possible). When two or more air conditioners are installed in a room, please contact your To operate only retailer to set the individual air conditioner signal codes. one of multipl
ملخص المحتوى في الصفحة رقم 15
TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec- trical breaker or disconnect the power supply plug, and consult authorized service personnel. WARNING! Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker or disconnect the power supp
ملخص المحتوى في الصفحة رقم 16
TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Symptom Items to check See Page CHECK ONCE Doesn’t operate at all: Has there been a power failure? — MORE Has a fuse blown out, or a circuit breaker been tripped? Is the timer operating? 8 to 9 Poor Cooling Is the air filter dirty? (or *Heating) Are the air conditioner’s intake filter or outlet port blocked? performance: Did you adjust the room temperature settings (thermo
ملخص المحتوى في الصفحة رقم 17
OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). AUTO Restart In Event of Power Interruption Should the power supply to the air conditioner be inter- Use of other electrical appliances (electric shaver, etc.) or rupted by a power failure, the air conditioner will restart nearby use of a wireless radio transmitter may cause the automatically in the previously selected mode once the air conditioner to malfunction. In this event, te