ملخص المحتوى في الصفحة رقم 1
User Command Specifications
1 Cover
Canon projector SX6/SX60/X600 User Commands
ver. 01.0100/05 2005.12.27
ver. 01.0100/04 2005.12.5
ver. 01.0100/03 2005.11.14
ver. 01.0100/02 2005.11.10
ver. 01.0100/01 2005.11.1
ملخص المحتوى في الصفحة رقم 2
User Command Specifications Version revision history 1 I. Version revision history I. Version revision history Numerical Date Description of revised version Where revised value 01.0100/01 2005.11.01 Version first created. 01.0100/02 2005.11.10 Version number of User Commands changed to "01.0100." Entire document Listing of the parameters for each command changed to the listing obtained by the "RANGE" command. Entire document "Character interval timeout" in communication specifications changed f
ملخص المحتوى في الصفحة رقم 3
User Command Specifications Contents 1 II. Contents II. Contents Item Page 1. Overview 1 2. Communication Specifications 2 3. Communication Flow 6 4. Command System 7 SX50 7 SX6 / SX60 / X600 8 5. Control Mode 9 6. Key/Emulation function 10 7. Power Management Mode 11 8. Command List 12 9. Details of command 13 REMOTE 14 LOCAL 15 POWER 16 AUTOSETEXE 17 BLANK 18 INPUT 19 AUTOPC 20 DOTS 21 TRACK 22 HPOS/VPOS 23 HPIX/VPIX 24 SEL 25 ASPECT 26 IMAGE 27 BRI 29 CONT 30 SHARP 31 GAMMA 32 DGAMMA 33 PROG
ملخص المحتوى في الصفحة رقم 4
User Command Specifications Contents Item Page GET INPUT 76 GET DOTS 77 GET TRACK 78 GET HPOS/VPOS 79 GET HPIX/VPIX 80 GET SEL 81 GET ASPECT 82 GET IMAGE 83 GET BRI 84 GET CONT 85 GET SHARP 86 GET GAMMA 87 GET DGAMMA 88 GET PROG 89 GET WB 90 GET WBRGB 91 GET SAT 92 GET HUE 93 GET RGBGAIN 94 GET RGBOFFSET 95 96 GET ACADJUST 97 GET MEMCADJ GET 6AXADJ 98 GET 6AXR~6AXY 99 GET LAMP 100 GET VKS/HKS 101 GET AVOL 102 103 GET MUTE 104 GET BVOL 105 GET IMAGEFLIP 106 GET PMM 107 GET PJON GET NOSIG 108 GET
ملخص المحتوى في الصفحة رقم 5
User Command Specifications Contents Item Page RANGE SAT 147 RANGE HUE 148 RANGE RGBGAIN 149 RANGE RGBOFFSET 150 RANGE ACADJUST 151 RANGE MEMCADJ 152 RANGE 6AXADJ 153 RANGE 6AXR~6AXY 154 RANGE LAMP 155 RANGE VKS/HKS 156 RANGE AVOL 157 RANGE MUTE 158 RANGE BVOL 159 RANGE IMAGEFLIP 160 RANGE PMM 161 RANGE PJON 162 RANGE NOSIG 163 RANGE NOSHOW 164 RANGE LOGOPOS 165 RANGE LANG 166 167 RANGE TERMINAL 168 RANGE KEYLOCK RANGE RCCH 169 RANGE GUID 170 RANGE DPON 171 RANGE LEDILLUMINATE 172 RANGE ZSTEPDRV
ملخص المحتوى في الصفحة رقم 6
User Command Specifications 1. Overview 1 1. Overview 1. Overview ・ These specifications describe the methods of controlling the projector from the PC over an RS-232C connection ・ Virtually all operations possible with the remote control can be controlled from the PC ・ The following symbols are used in these specifications. Symbol Description △ Space with 0 or more characters (20h), Tab (09h), or other separator □ Space with 1 or more characters (20h), Tab (09h), or other separator ▽ Separator
ملخص المحتوى في الصفحة رقم 7
User Command Specifications 2. Communication Specifications 4 2. Communication Specifications 2. Communication Specifications Communication system Item Specifications Communication system RS-232-C Start-stop synchronization Semi-duplex communication Transmission speed 19.2Kbps Character length 8 bits/character Stop bit 2 bits Parity None Transmission format Variable-length record with terminal as delimiter Maximum transmission Maximum of 256 characters (bytes) including delimiters length Delim
ملخص المحتوى في الصفحة رقم 8
User Command Specifications 2. Communication Specifications Commands Request transmissions sent from PC to the projector Transmission △ △ format characters One of CR (0Dh), LF (0Ah), CR+LF (0Dh+0Ah), Null (00h) Type Description Response Type Null Commands with a command character string length of 0. No command ■ OK processing is performed
ملخص المحتوى في الصفحة رقم 9
User Command Specifications 2. Communication Specifications Transmissions sent from Projector to PC in response to commands from PC Response Transmission format The first two characters are always : The first character indicates the response type. Response type Meaning Example i State response i:OK i:BUSY etc. w Warning w:USER_COMMAND.. e Error e
ملخص المحتوى في الصفحة رقم 10
User Command Specifications 2. Communication Specifications Other Transmission Transmission is recognized when delimiter is received. recognition Even if a maximum transmission length is received, the entire received transmission will be lost unless a delimiter is received. Parameter The is defined as shown below. value Definition :=▽ ▽.. ▽ := | | “” := [] <
ملخص المحتوى في الصفحة رقم 11
User Command Specifications 3. Communication Flow 1 3. Communication Flow 3. Communication Flow Transmission At the sending side (PC), the transmission is sent within character intervals of Tc (character interval timeout). sent Transmission At the receiving side (Projector), data able to be received within the character interval of Tc is held, and receiving of a received delimiter is considered “transmission received”. If a received character interval exceeds Tc or a delimiter is not received
ملخص المحتوى في الصفحة رقم 12
User Command Specifications 4. Command System SX50 1 4. CSX50 4. Command System SX50. User Command System Mode change Switch to Remote mode REMOTE Switch to Local mode LOCAL Setting/Control Display setting Input select INPUT Total number of dots adjustment DOTS Input signal settings Tracking adjustment TRACK Horizontal/Vertical position adjustment HPOS/VPOS Horizontal/Vertical resolution adjustment HPIX/VPIX Input signal selection SEL *User commands use only automatic selection of input signals.
ملخص المحتوى في الصفحة رقم 13
User Command Specifications SX6 / SX60 / X600 1 SX6 / SX60 / X600 SX6, SX60 or X600 User Command System Mode change Switch to Remote mode REMOTE Switch to Local mode LOCAL Setting/Control Display setting Input select INPUT Total number of dots adjustment DOTS Input signal settings Tracking adjustment TRACK Horizontal/Vertical position adjustment HPOS/VPOS Horizontal/Vertical resolution adjustment HPIX/VPIX Input signal selection SEL *User commands use only automatic selection of input signals.
ملخص المحتوى في الصفحة رقم 14
User Command Specifications 5. Control Mode 1 5. Control Mode 5. Control Mode The table below shows the states and limitations of the LOCAL and REMOTE control modes. Mode LOCAL mode REMOTE mode Item Mode where projector control/operation is Mode where projector control/operation is performed by the main unit or remote control. performed by a PC or other external device. Description Initial mode when microcomputer is started. (The PC or other external device is connected by a serial cable.) Sta
ملخص المحتوى في الصفحة رقم 15
User Command Specifications 6. Key/Emulation function 1 6. Key/Emulation function 6. Key/Emulation function The table below shows how the main unit/remote control keys and emulation function operate in each control mode LOCAL mode REMOTE mode Remote Main unit Remote control Main unit key Key/Emulation Unlock Unlock control lock key lock lock lock Remote control ○ × ○ POWER only × POWER only Main unit keys ○ ○ × POWER only POWER only × Remote control emulation × × × ○ ○ ○ Main unit key emulation
ملخص المحتوى في الصفحة رقم 16
User Command Specifications 7. Power Management Mode 1 7. Power Management Mode 7. Power Management Mode Concerning the processing for switching to the power management standby or exit mode in the remote or local mode Mode SX50 SX6/SX60/SX600 Remote The power management standby or exit mode is The power management standby or exit mode is not established. established when no signals are supplied for at least 5 (No countdown is initiated.) The countdown is aborted by any command other than GET/
ملخص المحتوى في الصفحة رقم 17
User Command Specifications 8. Command List 1 8. Command List 8. Command List Command type Item Commands Description Mode Control Setting Reference 1 REMOTE Switching to Remote mode ○ 2 LOCAL Switching to Local mode ○ Power supply control 3 POWER ○ 4 AUTOSETEXE Auto setup execution ○ 5 BLANK BLANK function ○ 6 INPUT Input terminal select ○ 7 AUTOPC Auto PC execution ○ 8 DOTS Total number of dots adjustment ○ 9 TRACK Tracking adjustment ○ Input 10 HPOS Horizontal position adjustment ○ signal 11
ملخص المحتوى في الصفحة رقم 18
User Command Specifications 9. Details of command 1 9. Details of command 9. Details of command Descriptions of each command are provided starting from the next page. The command descriptions have the format shown below. ※Command type Commands * Alphabetic command name Mode Control Setting Reference Function * This briefly describes the command function. Format * This indicates the command format. Parameter * This explains the required parameters for the command. Parameter types Response * This
ملخص المحتوى في الصفحة رقم 19
User Command Specifications (SET command) 0 PAGE 13
ملخص المحتوى في الصفحة رقم 20
User Command Specifications (GET command) 0 PAGE 13