ملخص المحتوى في الصفحة رقم 1
TOSHIBA Thermal Printer
B-SA4T SERIES
Option Installation Manual
Document No. EO15-33001A
Original Jul., 2005
(Revised Sep., 2005)
PRINTED IN JAPAN
ملخص المحتوى في الصفحة رقم 2
EO15-33001A (Revision Date: Feb. 14, 2008) TABLE OF CONTENTS Page 1. Cutter Module------------------------------------------------------------------------------------------------------1- 1 1.1 B-SA204-QM/ B-SA204-QM-R ----------------------------------------------------------------------------1- 1 1.2 B-SA204P-QM-R----------------------------------------------------------------------------------------------1- 4 2. Strip Module----------------------------------------------------------
ملخص المحتوى في الصفحة رقم 3
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 1. Cutter Module INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT WARNING! 1. Turn the printer power off and disconnect the power cord before installing an optional equipment. 2. Be careful not to pinch your fingers or hands with the covers. 3. Be careful not to injure your fingers when installing the cutter module. 1. Cutter Module 1.1 B-SA204-QM / B-SA204-QM-R B-SA204-QM/ B-SA204-QM-R is an optional cutter module f
ملخص المحتوى في الصفحة رقم 4
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 1. Cutter Module 2. Open the Front Cover wider. Remove the Front Cover by lifting it to disengage the hinge pins from the hinge. The Front Cover cannot be removed unless it is opened at an angle of over 100 degrees as the stoppers of the hinge prevent disengagement. 100° Front Cover Hinge Screw 3. Mount the Cutter Module Cover by inserting the hinge pins into the hinges. Cutter Module Cover Hinge 4. Fit the Cutter Un
ملخص المحتوى في الصفحة رقم 5
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 1. Cutter Module 5. Connect the Cutter Harness to the connector at the front of the printer. Connector Cutter Harness 6. Close the Cutter Unit and secure it to the printer with the Set Screw. Set Screw Cutter Unit 7. Close the Cutter Module Cover. • Media loading procedure------------- Owner’s Manual, Section 2.3 • Operation check------------------------ Owner’s Manual, Section 2.9 • System mode s
ملخص المحتوى في الصفحة رقم 6
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 1. Cutter Module 1.2 B-SA204P-QM-R B-SA204P-QM-R is an optional cutter module for the B-SA4TP Series (Plastic cover). CAUTION! Do not connect/disconnect the cutter harness to/from the printer within one minute from a power off to protect the internal electrical circuit of the printer. • Packing List The following parts are supplied with the kit. Make sure you have all items shown below. Cutter Unit (1 pc.) Cutter Module C
ملخص المحتوى في الصفحة رقم 7
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 1. Cutter Module 3. Mount the Cutter Module Cover by inserting the hinge pins into the hinges. Hinge Cutter Module Cover 4. Fit the Cutter Unit to the front of the printer by inserting the Hinge Pins into the Hinge Pin Holes. Hinge Pin Hinge Pin Hole Hinge Pin Hinge Pin Hole Cutter Unit 5. Close the Cutter Unit and secure it to the printer with the Set Screw. Set Screw
ملخص المحتوى في الصفحة رقم 8
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 1. Cutter Module 6. Secure the ground wire of the cutter unit to the printer with the B-3x6 screw removed in Step 1, as shown in the picture. 7. Connect the cutter harness to the connector at the front of the printer. Connector B-3x6 Screw Ground Wire Cutter Harness Ground Wire Cutter Harness 8. Close the Cutter Module Cover. After that, perform an operation check for a proper cut issue.
ملخص المحتوى في الصفحة رقم 9
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A (Revision Date: Jan. 19, 2006) 2. Strip Module 2. Strip Module NOTE: Make sure that the firmware version is V1.1 or greater. Firmware V1.0 does not support the strip module. 2.1 B-SA904-H-QM-R B-SA904-H-QM-R is an optional strip module for the B-SA4TM Series (Metal cover). • Packing List The following parts are supplied with the kit. Make sure you have all items shown below. Strip Unit (1 pc.) Strip Module Cover (1 pc.) SMW
ملخص المحتوى في الصفحة رقم 10
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 2. Strip Module 2. Open the Front Cover wider. Remove the Front Cover by lifting it to disengage the hinge pins from the hinge. The Front Cover cannot be removed unless it is opened at an angle of over 100 degrees as the stoppers of the hinge prevent disengagement. 100° Front Cover Hinge Screw 3. Mount the Strip Module Cover by inserting the hinge pins into the hinges. Hinge Strip Module Cover 4. Fit the Shaft Holders o
ملخص المحتوى في الصفحة رقم 11
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 2. Strip Module 5. Secure the Strip Unit to the printer with the two screws. Make sure that the Feed Roller Gear rotates smoothly. Strip Unit Feed Roller Gear SMW-3x6 Screw 6. Close the Strip Unit. Strip Unit 7. Connect the Strip Harness to the connector at the front of the printer. At this time, carefully avoid contact of the strip harness with the gears. Connector Gear Str
ملخص المحتوى في الصفحة رقم 12
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A (Revision Date: Jan. 19, 2006) 2. Strip Module • Attaching the Cutter The enclosed cutter is used to tear off the batch-issued labels. Attach the cutter with the two SMW-3x6 screws as shown in the picture below. Insert the leading edge of the labels into the opening under the cutter. SMW-3x6 Screw Opening Strip Unit Cutter Edge NOTE: Depending on the backing paper types, tearing off the backing paper a
ملخص المحتوى في الصفحة رقم 13
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A (Revision Date: Jan. 19, 2006) 2. Strip Module • System Mode Settings for Stripping PET Labels When using PET labels on the strip module, please set the following system mode parameters in advance. 1. Connect the printer to a PC. Turn the power ON. 2. Load a PET label stock on the printer. 3. Turn ON the printer while holding down the FEED PAUSE [FEED] key and [PAUSE] key. <1>DIAG. 4. When “<1>DIAG. “ is displayed on the LCD,
ملخص المحتوى في الصفحة رقم 14
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A (Revision Date: Jan. 19, 2006) 2. Strip Module 9. Turn off the printer, and then back to on. (Continued.) Send an issue command to the printer for strip issue. Turn the power OFF. Turn the power ON. Issue labels. 10. If necessary, fine adjust the print start position and strip position in the system Good mode. Print position NOTES: Adjustment is required. 1. It is recommended that the print start position and s
ملخص المحتوى في الصفحة رقم 15
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A (Revision Date: Jan. 19, 2006) 2. Strip Module 13. Press the [PAUSE] key repeatedly until Continued. “P.P.FEED” appears on the LCD. PAUSE 14. Press the [FEED] key to feed a label for checking the next label’s stop position. If <2>PARAMETER SET the next label stops with its top edge P.P.FEED +0.0mm aligning with the strip shaft edge, an adjustment is not required. Go to Step 15. PAUSE A label is fed. FEED
ملخص المحتوى في الصفحة رقم 16
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A (Revision Date: Jan: 19, 2006) 2. Strip Module 2.2 B-SA904P-H-QM-R B-SA904P-H-QM-R is an optional strip module for the B-SA4TP Series (Plastic cover). • Packing List Strip Unit (1 pc.) Strip Module Cover (1 pc.) SMW-3x6 Screw (4 pcs.) Cutter (1 pc.) Guide Roller (1 pc.) Installation Manual (1 copy) NOTE: When issuing labels in batch mode even though the strip module is
ملخص المحتوى في الصفحة رقم 17
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 2. Strip Module 2. Open the Front Cover wider. Remove the Front Cover by lifting it to disengage the hinge pins from the hinge. The Front Cover cannot be removed unless it is opened at an angle of over 100 degrees as the stoppers of the hinge prevent disengagement. 100° Front Cover Hinge Stopper 3. Mount the strip Module Cover by inserting the hinge pins into the hinges. Hinge Strip Module
ملخص المحتوى في الصفحة رقم 18
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A 2. Strip Module 5. Secure the Strip Unit to the printer with the two screws. Make sure that the Feed Roller Gear rotates smoothly. Strip Unit Feed Roller Gear SMW-3x6 Screw 6. Close the Strip Unit. Strip Unit 7. Close the Strip Module Cover. Perform an operation check for a proper strip issue. • Media loading procedure------------- Owner’s Manual, Section 2.3 • Operat
ملخص المحتوى في الصفحة رقم 19
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A (Revision Date: Jan. 19, 2006) 2. Strip Module • Attaching the Cutter The enclosed cutter is used to tear off the batch-issued labels. Attach the cutter with the two SMW-3x6 screws as shown in the picture below. Insert the leading edge of the labels into the opening under the cutter. SMW-3x6 Screw Opening Strip Unit Cutter Edge NOTE: Depending on the backing paper types, tearing off the backing paper aga
ملخص المحتوى في الصفحة رقم 20
INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT EO15-33001A (Revision Date: Jan. 19, 2006) 3. Wireless LAN Module: B-SA704-WLAN-QM 3. Wireless LAN Module: B-SA704-WLAN-QM The pictures used in this section are those of the B-SA4TM, and the installation procedures are common with the B-SA4TP unless otherwise noted. • Packing List The following parts are supplied with the kit. Make sure you have all items shown below. Wireless LAN Board (1 pc.) Antenna Cover (1 pc.) SMW-3x6 Screw (4 pcs.)