ملخص المحتوى في الصفحة رقم 1
OWNER’S MANUAL
1200/2000/3000
WATT SERIES
HIGH SURGE POWER INVERTERS
THE WHISTLER GROUP, INC.
CORPORATE HEADQUARTERS
13016 N. Walton Blvd.
Bentonville, AR 72712
TEL (479) 273-6012 FX (479) 273-2927
www.whistlergroup.com
CUSTOMER RETURN CENTER
1201 N. Dixieland Rd.
Rogers, AR 72756
Consumer Relations Tel (800) 531-0004
Email: info@whistlergroup.com
P/N 20562
© 2006 The Whistler Group, Inc.
ملخص المحتوى في الصفحة رقم 2
INTRODUCTION If you have questions concerning the Dear Whistler Owner, operation of this Whistler product For many of us, a vehicle is more than just transportation. It please call customer service: can be a mobile office, communications or entertainment center, or simply an expression of our personality. Whistler products are designed to make the time you spend in your 1-800-531-0004 vehicle more productive, more fulfilling, safer, or just simply more fun. Our mission is to provide products tha
ملخص المحتوى في الصفحة رقم 3
TABLE OF CONTENTS WHISTLER FEATURES A Word About Whistler Power Inverters Topic Page Whistler inverters convert low voltage, direct current (DC) to 110 Features Summary ..................................................................3-7 volt alternating household current (AC). The AC output is called Important Information................................................................8 “modified sine wave”. See “Technical Operating Principles” section for more information. Depending on the
ملخص المحتوى في الصفحة رقم 4
ملخص المحتوى في الصفحة رقم 5
FEATURES FEATURES a). ON/OFF Switch. This switch controls the flow of power from Voltage Indicator. This LCD display also monitors the voltage the power source to the inverter. It does not control the power being drawn from the battery by the inverter. The voltage is running from the inverter to the equipment or appliance being measured at the Negative and Positive power input terminals on the operated. inverter. The voltage level reading may be lower than the battery voltage due to the voltage
ملخص المحتوى في الصفحة رقم 6
IMPORTANT INFORMATION INVERTER INFORMATION Getting Started Power equipment and appliances which operate with motors or tubes require an initial surge of power to get them up IIm mp po or rt ta an nt t IIn nf fo or rm ma at tiio on n About Your New Whistler Inverter. and running. This power surge is referred to as the "starting This manual will provide you with directions for the safe and load" or "peak load." By comparison, electrical devices such efficient operation of your Whistle Power Inve
ملخص المحتوى في الصفحة رقم 7
INVERTER INFORMATION INVERTER INFORMATION Don’t Push It. start up load ratings comparable to your inverter wattage rating will not damage it. Although your Whistler power inverter has the capacity to provide power output (excess current) equal to approximately If a piece of equipment or an appliance will not operate, two times its rated wattage capacity for a very brief period, first confirm that the inverter has been properly connected it is designed to operate equipment and appliances with to
ملخص المحتوى في الصفحة رقم 8
BATTERY/CABLE INFORMATION BATTERY INFORMATION 1. To calculate the amp/hour of the battery, first determine • It may be advisable to operate the inverter from a bank its "reserve minutes" rating. (Deep cycle marine batteries of batteries of the same type in a "parallel" configuration. generally have the highest reserve minute ratings). This Two such batteries will generate twice the amp/hours rating typically is marked on the battery along with the of a single battery; three batteries will genera
ملخص المحتوى في الصفحة رقم 9
OPERATION CABLE INFORMATION Making the Connection. Adapter." Use of #0 gauge wire to make the connections to the inverter may require a "0 to 4 Gauge Adapter." Both adapters are available through electronic supply stores 1. Make certain that the Power switch is in the OFF (O) position. including Radio Shack. Radio Shack part number is listed below: 2. Connect the cables to the power input terminals at the rear of the inverter and tighten the screws to make a O Ring Adapter: RSU1153813
ملخص المحتوى في الصفحة رقم 10
OPERATION OPERATION Note: 7. Turn the inverter ON (I). Check the Meter on the • Loose connections can result in a severe decrease in front panel. The Voltage should read between 11 voltage which may cause damage to the wires and insulation. and 14 volts depending on the voltage of the power source. If the reading is not within this range, check • Failure to make proper connection between the inverter the voltage of the power source and the terminal and the power source will result in reverse pol
ملخص المحتوى في الصفحة رقم 11
OPERATION OPERATION • Check frequently to ensure that the input and The Power Source. output connections are secure. Loose connections When the engine is off, most batteries will provide ample power may damage the inverter, the power source, or supply to the inverter for one to two hours. The actual length may generate excessive heat. of time is a function of several variables including the age and • The following precautions apply to the 3000 watt condition of the battery, the number of batte
ملخص المحتوى في الصفحة رقم 12
OPERATION OPERATION and typically is referenced on the back of the microwave. If 2. Change the relative positions of the inverter, antenna the operating power requirement does not appear on the cables and television power cord. back of the microwave, check the owner’s manual or contact the manufacturer. 3. Isolate the television, its power cord and antenna cables from the 12 volt power source by running an extension Some Powerful Advice. cord from the inverter to the television set. Your Whi
ملخص المحتوى في الصفحة رقم 13
OPERATION OPERATING PRINCIPALS radiators or other sources of heat. Do not place the inverter in direct sunlight. 145 volts peak 115 volts RMS • VENTILATION. In order to disperse the heat generated while the inverter is in operation, keep it well ventilated. While in use, maintain several inches of clearance around 0 the top and sides of the inverter. • FUMES & GASES. Avoid using the inverter near flammable materials. Do not place the inverter in areas such as battery compartments, where fumes
ملخص المحتوى في الصفحة رقم 14
OPERATING PRINCIPALS/SUMMARY OPERATION SUMMARY • Before attempting to use a battery charger see page 19. • Before attempting to use medical equipment see page 8. • Use the heaviest gauge wire (smaller the number, the larger or heavier the cable) available to connect the inverter to the power source. • When operating the inverter with the engine off, start the A true sine wave typical of home AC outlet. engine every 30 to 60 minutes and let it run for at least 10 minutes to recharge the battery.
ملخص المحتوى في الصفحة رقم 15
OPERATION SUMMARY TROUBLESHOOTING PROBLEM: TV Interference • Always operate the inverter in accordance with the Problem Solution instructions in this manual. Failure to do so may result Electrical interference from Add a Ferrite data line in property damage, personal injury, or loss of life. filter inverter. on to the TV power cord. This filter is available at • While connecting the inverter to the power source, RadioShack, or other make certain that the inverter is well removed from electro
ملخص المحتوى في الصفحة رقم 16
TROUBLESHOOTING SPECIFICATION WHISTLER 1200 WATT INVERTER SPECIFICATIONS Overload or High Temp LED on Maximum Continuous Power……………………………1200 Watts Maximum Surge Capability (Peak Power).....................2400 Watts* * Problem Solution No Load Current Draw………………………………...............< 1.3A Equipment has a high Turn inverter power switch Waveform……………………………….............Modified Sine Wave start up surge. OFF (O) and then ON (l) Operating Input Voltage Range…………….....11-15+0.5 Volts DC again unti
ملخص المحتوى في الصفحة رقم 17
WARRANTY WARRANTY IMPORTANT: Whistler will not assume responsibility for loss Consumer Warranty or damage incurred in shipping. Therefore, please ship your The Whistler 1200/2000/3000 series inverters are warrantied inverter insured with return receipt requested. to the original purchaser for a period of (2) two years, from the date of original purchase, against all defects in materials and workmanship. This limited warranty is void if the unit 2. Include with your unit the following informatio
ملخص المحتوى في الصفحة رقم 18
WARRANTY MEMO The out of warranty service fee for your 1200 Whistler inverter is $90.00, 2000 Whistler inverter is $150.00 and 3000 Whistler inverter is $250.00. If you require out of warranty service, please return your inverter as outlined in the section “Service Under Warranty” along with a certified check or money order for the correct amount. Payment may also be made by MasterCard, VISA or American Express; personal checks are not accepted. In the event repairs cannot be covered by the ser