ملخص المحتوى في الصفحة رقم 1
www.mgeups.com MGE UPS SYSTEMS
Pulsar
EXtreme CLA
1500C
Installation and user
manual
51031998EN/AA - Page 1
ملخص المحتوى في الصفحة رقم 2
Introduction Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar EXtreme range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS. MGE UPS SYSTEMS pays great attention to the environmental impact of its products. Measures that have made Pulsar EXtreme a reference in environmental protection include: w the eco-design approach used in product developm
ملخص المحتوى في الصفحة رقم 3
Safety Safety rules Safety of persons When the batteries are connected to the UPS, the outlets may be energised even if the UPS is disconnected from the AC input source. Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personnel. The UPS must be properly earthed. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3.5 mA. Product safety UPSs must be connected to a nearby
ملخص المحتوى في الصفحة رقم 4
Foreword Using this document Information may be found primarily by consulting: w the contents, w the index. Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Earth cables Other cables Page 4 - 51031998EN/AA
ملخص المحتوى في الصفحة رقم 5
Contents 1. Presentation 1.1 Pulsar EXtreme range................................................................................................................. 7 Tower model.................................................................................................................................... 7 Rack model ..................................................................................................................................... 7 1.2 Back ................................
ملخص المحتوى في الصفحة رقم 6
Contents 3.4 Personalisation (optional) ........................................................................................................... 22 Function ........................................................................................................................................ 22 "ON / OFF conditions" tab............................................................................................................. 22 "Battery" tab ................................................
ملخص المحتوى في الصفحة رقم 7
1. Presentation 1.1 Pulsar EXtreme range Tower model Dimensions in mm Weight in kg (H x W x D) 235.5 x 145 x 505 9.5 Rack model Dimensions in mm Weight in kg (H x W x D) 88 (2U) x 482.6 x 493 12.5 51031998EN/AA - Page 7 EX1000 Rack
ملخص المحتوى في الصفحة رقم 8
1. Presentation 1.2 Back Tower model 4 1 slot for communications-card option. 1 2 RS232 communications port. 2 3 3 USB communications port. USB RS232 9 4 four outlets for direct connection of protected equipment. 10 6 input circuit breaker. 7 socket for connection to AC-power source. 1 8 connector for battery connection. 8 2 9 pushbutton to test phase/neutral inversion of AC-power source. 11 6 10 LED indicating phase/neutral inversion of AC-power source. 7 11 two programmable outlets (outlet 1 a
ملخص المحتوى في الصفحة رقم 9
1. Presentation Rack model 1 3 8 11 4 USB 2 1 RS232 2 9 10 6 7 8 slot for communications-card option. connector for battery connection. 1 2 RS232 communications port. pushbutton to test phase/neutral inversion of 9 AC-power source. 3 USB communications port. 10 LED indicating phase/neutral inversion of 4 four outlets for direct connection of AC-power source. protected equipment. 11 two programmable outlets (outlet 1 and 2). 6 input circuit breaker. 7 socket for connection to AC-power source. 51
ملخص المحتوى في الصفحة رقم 10
1. Presentation 1.3 Control panel Alarms % battery ␣␣␣␣␣ % load remaining % 12 UPS overload. 100 % 100 % 100% 13 electronics fault. 80 % 80 % 80% 50% battery fault. 50 % 50 % 14 20% 15 20 % 20 % % 16 hold down to display percent load: - lamp test or buzzer OFF. test - forced transfer to bypass and back 17 by pressing button 3 times in less than 5 seconds. 1 18 status of programmable outlet 1: Supplied with power 2 19 status of programmable outlet 2: Status change in progress.
ملخص المحتوى في الصفحة رقم 11
2. Installation 2.1 Unpacking and checks Tower model 24 26 25 29 27 28 30 two cords for connection of the protected equipment. 24 RS 232 communications cable. 25 USB communications cable. 26 "UPS Driver" diskette for UPS personalisation. 27 "Solution Pac" CD ROM. 28 documentation. 29 ␣ 30 box for battery connection. 51031998EN/AA - Page 11
ملخص المحتوى في الصفحة رقم 12
2. Installation Rack model 24 24 25 26 31 27 28 29 30 ␣24 two cords for connection of the protected equipment. ␣25 RS 232 communications cable. ␣26 USB communications cable. ␣27 "UPS Driver" diskette for UPS personalisation. ␣28 "Solution Pac" CD ROM. ␣29 documentation. ␣30 box for battery connection. ␣31 telescopic rails for mounting in 19" bay with mounting hardware. Page 12 - 51031998EN/AA EX1000 Rack
ملخص المحتوى في الصفحة رقم 13
2. Installation 2.2 Installation of the rack version Rack mounting diagram with rails. 1 3 3 3 4 3 2 The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS. 51031998EN/AA - Page 13 EX1000 Rack
ملخص المحتوى في الصفحة رقم 14
2. Installation 2.3 Connection to the RS 232 or USB communications port (optional) 1 - Connect the RS 232 25 or USB 26 communications cable to the serial port or the USB port on the computer. 25 2 - Connect the other end of the USB RS232 communications cable 25 or 26 to the RS 26 2 3 232 2 or USB 3 communications port on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. USB 3 2 RS232 The RS 232 and USB communications ports cannot
ملخص المحتوى في الصفحة رقم 15
2. Installation 2.4 Installation of the communications-card option Tower model 1 Slot for the communications-card It is not necessary to shut down the UPS to option. install the communications card: RS232 USB 1 - Remove the slot 1 cover secured by two screws. 2 - Insert the card in the slot. 3 - Secure the card with the two screws. 1 2 Rack model 1 Slot for the communications- card option. 2 1 USB RS232 51031998EN/AA - Page 15
ملخص المحتوى في الصفحة رقم 16
2. Installation 2.5 Battery connection Warning The batteries should be connected only by qualified electrical installation specialists. The work involved in connecting the batteries must be carried out in accordance with all applicable rules and regulations, respecting all safety measures for working on live equipment, i.e. qualified personnel using insulated gloves, protective eyeware, insulated tools, etc. Interconnecting the batteries to obtain the required configuration Wire the batteries as
ملخص المحتوى في الصفحة رقم 17
2. Installation Tower model 8 b a OFF c 40 A curve C d 6 m max. Cable and circuit-breaker not supplied e 140 g 10 10 f 10 10 j i h 51031998EN/AA - Page 17 40A 12V-65Ah 40A
ملخص المحتوى في الصفحة رقم 18
2. Installation Rack model 1 8 2 1 2 b OFF c 40 A curve C a 6 m max. d Cable and circuit-breaker not provided e 140 g 10 10 f 10 10 j 1 2 1 2 i h Page 18 - 51031998EN/AA USB RS232 40A 12V-65Ah 40A
ملخص المحتوى في الصفحة رقم 19
2. Installation 2.6 UPS connection and settings Tower model Connecting the UPS to the AC-input source 1 - Remove the power cord supplying the 4 equipment. Check cord characteristics (> 250 V, 10 A, see the technical sheet). 2 - Connect the cord to the AC-power socket ␣␣7 on the UPS, then to the AC-power wall outlet. Setting the UPS for the installed battery configuration 11 (For a 2-hour configuration, skip this step, this is the default setting for the UPS). 24 The UPS is set using the ÒUPS D
ملخص المحتوى في الصفحة رقم 20
3. Operation 3.1 Start-up The protected equipment connected to the UPS can be energised, whether AC input power is available or not. Caution: the AC input power source must be present when energising for the first time. Press the ON / OFF button 23 . The buzzer beeps and all the LEDs go ON. The buzzer beeps twice, then: - If AC input power is available, LED 21 goes ON, indicating operation 21 in ON-LINE mode. - If AC input power is not available and the UPS is configured for 22 automatic rest