ملخص المحتوى في الصفحة رقم 1 
                    
                        UPS OPERATING INSTRUCTIONS
PROTECT 1.
PROTECT 1.100 
PROTECT 1.150
PROTECT 1.200                                                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Thank you for deciding to purchase the PROTECT 1. UPS from AEG Power Solutions.  The following safety instructions are an important part of  the operating instructions are will protect you against  problems from operating errors and possible dangers.  Please read these instructions carefully prior to  commissioning! 2                                                                                                                                                                                     
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        1 Notes on these Operating  Instructions Duty to provide information These operating instructions will help you to install and  operate the Uninterruptible Power Supply (UPS), PROTECT 1.100, PROTECT 1.150 or PROTECT 1.200 as well as the  corresponding external battery units PROTECT 1.100 BP or  PROTECT 1.BP20, all referred to as PROTECT 1 in the  following, safely and correctly. These operating instructions  contain important information for avoiding dangers. Please read these instructions caref
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        liability for consequential damage. AEG will rescind all  obligations such as warranty agreements, service contracts,  etc. entered into by AEG or its representatives without prior  notice in the event of maintenance and repair work being  carried out with anything other than original AEG parts or  spare parts purchased from AEG. Handling PROTECT 1. is designed and constructed so that all  necessary steps for start-up and operation can be performed  without any internal manipulation of the unit.
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Table of Contents 1 Notes on these Operating Instructions .............................3 2 General Information ..........................................................7 2.1 Technology ................................................................7 2.2 System Description....................................................8 2.3 Technical Data.........................................................11 3 Safety Regulations..........................................................15 3.1 Important
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        6 Start-Up...........................................................................37 6.1 Operating Modes .....................................................38 6.1.1 Normal Operation...............................................38 6.1.2 Battery Operation / Autonomous Operation.......39 6.1.3 Bypass Operation ..............................................40 6.1.4 Manual Bypass ..................................................41 6.1.5 Unit overload............................................
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        2 General Information 2.1 Technology PROTECT 1. is an Uninterruptible Power Supply (UPS) for essential loads such as small  data centres, servers, network components,  i telecommunications equipment and similar  units. It consists of: ♦ Mains filter with overvoltage protection (appliance  protection / class D) and mains energy backfeed  protection ♦ Rectifier section with PFC logic  (power factor correction unit) ♦ Separate battery charger with  switch mode power supply technology ♦ IGBT inverte
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        2.2 System Description The UPS is connected between the public utility mains and  the loads to be protected. The power section of the rectifier converts the mains voltage to  DC voltage for supplying the inverter. The circuit technology  used (PFC) enables sinusoidal current consumption and  therefore operation with little system disturbance. A separate,  second rectifier (charging REC set up using switch mode power  supply technology) is responsible for charging or trickle-charging  the battery
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        IGBT power semiconductors of the inverter, a voltage system of  the highest quality and availability on the secured busbar. In the event of mains faults (such as e.g. current failures), the  voltage continues to be supplied from the inverter to the load  without any interruption. From this point onwards, the inverter  draws its power from the battery instead of the rectifier. Since no  switching operations are necessary, there is no interruption in  the supply to the load. The automatic electron
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Parallel system with PROTECT 1.150 Number of UPS units Available power 1 2 3 0 15 kVA 30 kVA 45 kVA Active redundancy 1 --- 15 kVA 30 kVA degree 2 --- --- 15 kVA Parallel system with PROTECT 1.200 Number of UPS units Available power 1 2 3 0 20 kVA 40 kVA 60 kVA Active redundancy 1 --- 20 kVA 40 kVA degree 2 --- --- 20 kVA 10                                                                                                                                                                              
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        2.3 Technical Data Type rating PROTECT 1.100 10000 VA (cos ϕ = 0.7 ind.) 7000 W  PROTECT 1.150 15000 VA (cos ϕ = 0.7 ind.)  10500 W PROTECT 1.200 20000 VA (cos ϕ = 0.7 ind.) 14000 W UPS input 3ph~ / N / PE Rated connection voltage 400 V/ 230 VAC Voltage range without 304 VAC – 478 VAC ± 3 %  battery operation (rectifier) 176 VAC – 261 VAC VAC ± 3 % (bypass) Frequency 50 Hz / 60 Hz  (autom. detection) Frequency tolerance range ± 4 Hz  Current consumption at full load (max.) PROTECT 1.100 13 A (3p
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Overload behaviour Up to 105% continuous; with mains supply > 105% – < 130% for 10 min. 130% for 1s Following this, automatic,  uninterrupted switchover to  integrated bypass (SBS).  Switch-off after 1 min if overload  continues to be present. (Switch  back if overload decreases = load  < 90%) Overload behaviour with Up to 105% continuous; battery operation > 105% for 10 s Short-circuit behaviour 2.5 x I for 100 ms N Battery Standby times with external standard battery units Standby times (full 
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        Communication Interfaces RS232 Sub-D (9-pin) Additionally: Communication slot  for expansions (e.g. AS/400 /  USB / remote signal indicator / SNMP, …) Shutdown software on CD “CompuWatch” for all common  operating systems, e.g.  Windows, Linux, Mac, Unix,  FreeBSD, Novell, Sun General data Classification VFI SS 111 acc. to IEC 62040–3  Sustained transformer  technology Full load efficiency > 90% / > 88% (AC-AC / DC-AC) Inherent noise (1m distance) PROTECT 1.100 < 55 dB(A) PROTECT 1.150 < 60 dB(A
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        Housing colour: Blackline Weight: PROTECT 1. 100 39 kg PROTECT 1. 150 55 kg PROTECT 1. 200 55 kg PROTECT 1. 100 BP 135 kg PROTECT 1. BP20 170 kg Dimensions W x H x D: PROTECT 1.100/1.150/1.200 260 mm x 717 mm x 670 mm PROTECT 1.100 BP 260 mm x 717 mm x 670 mm PROTECT 1.BP 20 260 mm x 717 mm x 810 mm Directives The PROTECT 1. meets the product standard EN 50091. The CE mark on the unit confirms compliance with the EC  outline directives for 73/23 EEC – Low voltage and for 89/336  EEC – Electromag
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        3 Safety Regulations 3.1 Important Instructions and Explanations The instructions for operation and maintenance, as well as  the following safety regulations must be complied with to  ensure the safety of personnel as well as the continued  availability of the unit. All personnel installing/dismantling,  starting up, operating or servicing the units must be familiar  with and observe these safety regulations. Only trained and  qualified personnel may perform the work described, using  tools, equ
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        ♦ Verify that the unit is disconnected from the power  supply ♦ Earth and short-circuit the unit ♦ Provide protection by covers or barriers for any  neighbouring live parts 3.3 Qualified Personnel The PROTECT 1. may only be transported, installed,  connected and serviced by qualified personnel who are  familiar with the pertinent safety and installation regulations.  All work performed must be inspected by responsible expert  personnel. The qualified personnel must be authorised by the  responsi
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        For health and safety reasons, the unit must be  earthed correctly! The PROTECT 1. may only be operated with or connected to a three-phase power system with protective grounding using  a mains connection cable with PE conductor that has been  tested according to German standards (VDE). Risk of burning! The battery has powerful short-circuit currents.  Incorrect connection or isolation faults can lead to  melting of the plug connections, sparking potential  and severe burns! The unit has a warnin
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        ♦ Ensure that no fluids or foreign bodies can penetrate  the housing! ♦ Do not block the air vents of the unit! Make sure, for  example, that children do not insert any objects in the  ventilation openings! ♦ Do not connect household appliances such as  hairdryers to the UPS! Also take care when working  with motor loads. It is essential to avoid back-feeding  the inverter, e.g. if the load is intermittently operated in  regenerative mode. Danger! Electric shocks! Even after the mains voltage ha
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Therefore, take the following safety precautions when working  with batteries: ♦ Take off watches, rings and other metallic objects!  ♦ Only use tools with insulated handles! Avoid using multiple outlet adapters with a  central on/off switch as protection against  uncontrolled load switch-off as well as for i avoiding peak inrush currents. Switch OFF the UPS using its main switch if you do not intend  to use it for some time. PROTECT 1. must be switched off  every evening if the electricity supp
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        3.5 CE Certificate 20