ملخص المحتوى في الصفحة رقم 1
PROFESSIONAL WEATHER CENTER PROFESSIONAL WEATHER CENTER
WS-1510-IT WS-1510-IT
Instruction Manual Instruction Manual
Congratulations on purchasing this state-of-the-art Professional
Weather Center as an example of excellent design and innovative
Table of Contents
technology. Featuring time, date, calendar, weather forecast, wind
Topic Page
direction and speed, rainfall, indoor temperature, outdoor temperature
Features 2
and outdoor humidity, air pressure and various alarm settings
ملخص المحتوى في الصفحة رقم 2
Note: gauge by moving the wind-vane; tilting the rain sensor to hear the When putting the Weather Center into operation, it is important to impact of the internal moving seesaw, etc. (see Positioning perform in close proximity (e.g. on a table) a complete wiring and set-up below). of the system. This step is important to test all components for correct 7. Time and date shall be manually set (See Manual Setting below). function before placing and mounting them at their final destinations 8. A
ملخص المحتوى في الصفحة رقم 3
SET key The LCD screen is split into 5 sections displaying the following • Press and hold to enter manual setting modes: LCD contrast, information: Manual time setting, 12/24 hour time display, Calendar setting, ºF/ 1. Time and date/ indoor temp/ second ºC temperature unit, Wind speed unit, Rainfall unit, Pressure unit, 2. Wind data Relative pressure reference setting, Weather tendency threshold 3. Outdoor temperature, Dew point and humidity, setting, Storm warning threshold setting and Sto
ملخص المحتوى في الصفحة رقم 4
4. Use the + or MIN/MAX key to set the month. The relative air pressure can be set as inHg or hPa. The default unit is 5. Press the SET key to confirm the month and enter the date setting inHg. mode. The date digit will start flashing. 1. Use the + or MIN/MAX key to toggle between the unit “inHg" or 6. Use the + or MIN/MAX key to set the date. “hPa” 7. Confirm all calendar settings with the SET key and enter the °F/°C 2. Confirm the unit with the SET key and enter the RELATIVE TEMPERATURE U
ملخص المحتوى في الصفحة رقم 5
to set the low outdoor temp alarm value. (Keep holding the key will allow the value to increase faster.) 6. Press the ALARM key to confirm the setting. The digit will stop The Weather Center can be set to alert when a specific weather flashing. Press the SET key to switch on or off the alarm. (The condition is reached. showing of the icon ((( ))) means that the alarm is switched on.) 7. Press the HISTORY key or wait for about 30 seconds and the The following Weather Alarm settings
ملخص المحتوى في الصفحة رقم 6
Center will be more accurate compared to use in areas where the compares the result. The "0" in the middle of this scale determines the weather is stagnant most of the time (for example mostly sunny). current air pressure. If the Weather Center is moved to another location significantly higher The vertical axis represents the air pressure changes in inHg (+0.12, or lower than its initial standing point (for example from the ground floor +0.06, 0, -0.06, -0.12. The “0” represents the curr
ملخص المحتوى في الصفحة رقم 7
7. Min Wind chill temperature with the date and time of recording 2. Max outdoor temperature with the date and time of recording 3. Min dew point temperature with the date and time of MIN icon recording Time and date Time and date of recording of recording MIN wind chill value MIN dew point value MIN icon MIN icon 8. Max Wind chill temperature with the date and time of recording 4. Max dew point
ملخص المحتوى في الصفحة رقم 8
2. Press ALARM key once to return to the normal display mode. The "BUZZER OFF" icon will still be shown. BUZZER OFF icon The total rainfall value is To re-enable the buzzer: counted from this time and 1. When the BUZZER OFF icon is shown on LCD, press and hold date the SET key until the BUZZER OFF icon disappears. 2. Press ALARM key once to return to the normal display mode. The "BUZZER OFF" icon will no longer be shown. Then the alarm will sound norm
ملخص المحتوى في الصفحة رقم 9
When you require additional length to properly mount your sensor, you can use a La Crosse Technology extension cable. The extension cable is 32 feet in length and comes with the appropriate connecter attached, First, check that the wind-cups and the wind-vane can rotate freely Please visit your local retailer or www.greatbigoutlet.com to purchase. before fixing the unit. For correct and accurate readings, it is important to mount the sensor so that the front (marked E) is pointing i
ملخص المحتوى في الصفحة رقم 10
Crosse Technology, Ltd product to a La Crosse Technology, Ltd www.lacrossetechnology.com/1510 authorized service center. La Crosse Technology, Ltd will pay ground return shipping charges to the owner of the product to a USA address FAQ WS-1510-IT only. Congratulations on purchasing this state-of-the-art Professional Weather Center. Your La Crosse Technology, Ltd warranty covers all defects in material Remember, for your Weather Station to work properly, it must be and workmanship
ملخص المحتوى في الصفحة رقم 11
2. SETTING THE HOUR MANUALLY: 11. RELATIVE AIR PRESSURE UNIT: The Hour will be flashing. Use the PLUS button to increase the hour. InHG (inches of mercury) should now be flashing. This can be set in Use the MIN/MAX button to decrease the hour. If using 12-hour Time inHG or hPa (hectopascal). To change, press and release the PLUS or Mode, be sure to set the hour for AM or PM. Press and release the MIN/MAX button to make your selection. Press and release the SET SET button once to mo
ملخص المحتوى في الصفحة رقم 12
Distance: It may also be that the distance between the transmitter and Check that nothing is binding the wind vane. Is it sticking in one the receiver is too great or has too many obstacles between the units to particular direction? Check sources of interference above. allow the signal to reach the transmitter. Rain is inaccurate Direction is incorrect speed is fine: Interference: Are there sources of radio frequency or electromagnetic Be sure to observe the Directions listed on the
ملخص المحتوى في الصفحة رقم 13
2. Press MIN/ MAX to view older records. Press MIN/MAX and If your screen has black on it that may look like and ink blob, this is PLUS key to view "Previous" and "Next" record respectively. The likely do to the display unit falling or being impacted in some way. records are made at 3-hour intervals) Unfortunately, this is not a warranty issue. Press the SET key to see items normally viewed in “mode 2”. – Power Source Battery Leakage - Forecast Icons Battery leakage is not a warr