ملخص المحتوى في الصفحة رقم 1
Timer
0
Mode 0n/0ff F
Fan Only Cool
hr
Dry Money Saver®
Auto
Fan
Speed Swing Power
Temp
CP10 CP12
Timer
Mode 0n/0ff 0F
Fan Only Cool
hr
Dry Money Saver®
Fan Auto Power
Speed Swing
Temp
201 7
ملخص المحتوى في الصفحة رقم 2
Congratulations! Thank you for choosing Friedrich. Your Friedrich unit is designed for maximum comfort and quietness. Table of Contents Introduction ..................................................................................2 Safety Precautions.......................................................................3 How to operate your Friedrich ...................................................5 Adjusting the Air Flow Direction.................................................6 Care and M
ملخص المحتوى في الصفحة رقم 3
H S I L G N E Introduction Before Operating Your Unit Make sure the wiring is adequate or our unit. f y If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1. r DO NOT use an extension co d. The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not. Make sure that the receptacle
ملخص المحتوى في الصفحة رقم 4
Safety Precautions To prevent injury and property damage, follow these instructions. ■Incorrect operation due to ignoring instructions can cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION properties only. ■Meanings of symbols used in this manual are as shown below. Never Do This Always Do This WARNING Plug in the power p
ملخص المحتوى في الصفحة رقم 5
ملخص المحتوى في الصفحة رقم 6
3 5 7 A ir Power P urifier 1 Timer 0 F Mode 0n/0ff Temp Fan Only Cool hr 2 Dry Money Saver® Fan S peed 4 Auto Fan Power Speed Swing Mode T imer Temp 5 3 Auto A Swing S wing 6 4 2 6 1 6.AUTOSWING dry operation. (dehumidify operation) This button can automatically control the air flow direction. 7 To receive the signal from remote controller.
ملخص المحتوى في الصفحة رقم 7
ENGLISH Adjusting the Air Flow Direction Vent Control For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air. Part B CLOSE VENT OPEN NOTE : Before using the ventilation feature, position the lever, as shown. First, pull down part A to horizontal line with par . t B Part A Adjusting the Air Flow Direction Airflow can be adjusted by changing the direction of the air conditioner's louvers. • Adjusting Horizontal Air Flow Dir
ملخص المحتوى في الصفحة رقم 8
Care and Maintenance Turn the power off and unplug the power plug before cleaning the air conditioner. Air Filter The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner. How to remove the air filter 1. Open the inlet grille upward by pulling out the bottom of the inlet grille.(a) 2. Remove the air filter from the front grille assembly by pulling the air filter up slightly. 3. Wash t
ملخص المحتوى في الصفحة رقم 9
T i m e r M o d e F a n S p e e d T e m p P u r i f i e r P o w e r A i r ENGLISH Timer Mode 0n/ 0ff 0F an Only Cool hr Dry Money Saver® Fan Auto Power Speed Swing Temp Hardware Location Product Features CAUTION This appliance should be installed in accordance with local and national wiring regulations. This manual acts as a guide to help to explain product features. Vertical Air Deflector (Horizontal Louver) Horizontal Air Deflector (Vertical Louver) Air Discharge Cabinet Air Intake(Inlet Gril
ملخص المحتوى في الصفحة رقم 10
Installation Instructions Read these instructions completely and carefully. Tools You Will Need ❒ Phillips-head screwdriver ❒ Scissors or knife ❒ Flat-blade screwdriver ❒ Pencil ❒ Ruler or tape measure ❒ Level ❒ Hammer Before You Begin NOTE TO INSTALLER: Leave these CAUTION: instructions with the air conditioner after Do not under any circumstances, cut or remove installation is complete. the third (ground) prong from the power cord. Do not change the plug on the power cord of NOTE TO CONSUMER:
ملخص المحتوى في الصفحة رقم 11
ENGLISH How to Install the Unit 1. To prevent vibration and excess noise, Fence make sure the unit is installed securely Awning and firmly Cooled air 2. Install the unit where the sunlight does not Heat shine directly on the unit. radiation 3. The outside of the cabinet must extend outward for at least 12" and there shouldbe no obstacles, such as a fence or wall,within 20" from the back 1 About /2" of the cabinet, as it will prevent heat radiation Over 20" of the condenser. Restriction of ou
ملخص المحتوى في الصفحة رقم 12
Installation Kit Contents Type A:13EA Type B:3EA Type C:5EA 1 2 3 (SCREW) (SCREW) (SCREW) Type D:2EA Type E:2EA Type F:2EA Type G:2EA 5 6 7 (NUT) 4 (FRAME CURTAIN) (SILL SUPPORT) (BOLT) 10 10 Type H:1EA Type K:2EA Type L:1EA Type M:1EA 8 11 9 (FOAM-STRIP) (FRAME-GUIDE) (WINDOWLOCKINGBRACKET) (FOAM-PE) Type N:1EA 12 (DRAIN JOINT PIPE) Have the following tools available for installation: * Screwdriver (Slotted and Phillips) * Ruler * Knife * Hammer * Pencil * Level 11 10mm 16mm 16mm
ملخص المحتوى في الصفحة رقم 13
ENGLISH 0 F hr 0 F hr 0 F hr Timer Mode 0n/ 0ff 0F an Only Cool hr Dry Money Saver® Fan Auto Speed Swing Power Temp Timer Mode 0n/ 0ff 0F an Only Cool hr Dry Money Saver® Fan Auto Speed Swing Power Temp Timer Mode 0n/ 0ff 0F an Only Cool hr Dry Money Saver® Fan Auto Speed Swing Power Temp Suggested Tool Requirements SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL, LEVEL Shipping screws PREPARATION OF CHASSIS 1. Remove the screws which fasten the cabinet at both sides and at the back. (Fig .1)
ملخص المحتوى في الصفحة رقم 14
Cabinet Installation 1. Open the window. Mark a line on center of the window stool.Carefully place the cabinet on the window stool and align the center mark on the bottom front with the center line marked in the window stool. (Fig. 1) Upper Guide Window stool Front Angle Fig. 1 2. Pull the bottom window sash down behind the Upper Guide until they meet. (Fig. 2) Window Sash Upper guide NOTE: Do not pull the window sash down so 11 Foam-PE tightly that the movement of Frame 5 Curtain is restricte
ملخص المحتوى في الصفحة رقم 15
ENGLISH /0ff an Only Cool Dry Money Saver Power Temp Timer Mode 0n 0F hr ® Speed Fan Swing Auto 6. The cabinet should be installed with a very slight tilt (about 1/2") downward toward the outside Screw(Type B) 2 (See Fig. 5). Adjust the bolt and the nut of Sill Support 6 for balancing the cabinet. 6 Sill Support 7. Attach the cabinet to the window stool by driving Sash track the screws 2 [Type B: Length 16mm (5/8 inch) and below.] through the front angle into window stool. (Fig. 5) 5 8. P
ملخص المحتوى في الصفحة رقم 16
12. Attach the Window Locking Bracket 10 with a Type C Window locking screw 3 . ( Fig. 9) bracket 10 Fig. 9 13. Attach the front grille to the cabinet by inserting the tabs on the grille into the tabs on the front of the cabinet. Push the grille in until it snaps into place. (Fig. 10) Fig. 10 14. Pull down the inlet grille and secure it with a Type A screw 1 through the front grille. ( Fig. 11) 15. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for plugging t
ملخص المحتوى في الصفحة رقم 17
H S I L G N E Through-the-Wall Installation Instructions-Optional The case may be installed through -the-wall 1 (cont.) IMPORTANT in both existing and new construction. Secure with 14 wood screws anchored at D Read completely, then follow step-by-step. Ieast an inch into the wall support structure. NOTE: Obtain all materials locally for NOTE: Drill pilot holes, if necessary, for mounting the air conditioner through- proper installation. If the frame is oversized, the wall. - use shims to prevent
ملخص المحتوى في الصفحة رقم 18
Troubleshooting Tips Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the thermostat click when the compressor cycles on and off. • Water will collect in the base pan during high humidity or on rai
ملخص المحتوى في الصفحة رقم 19
ENGLISH FRIEDRICH AIR CONDITIONING CO. Post Office Box 1540 • San Antonio, Texas 78295-1540 (210) 357-4400 • FAX (210) 357-4490 ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided room air conditioner is reasonably accessible for service. Any additional labor cost for removing inaccessible un