ملخص المحتوى في الصفحة رقم 1
Split System Air Conditioner
seer
13
2AC13 Features and Benefits
• Durable compressors with • Hinged control panel allows
internal pressure relief simple access to internal
valves and inherent thermal components
protection
• 45-degree service valves for
• High-quality condenser coil easy hook-up and service
with copper tubing and
• Liquid line filter drier
enhanced louvered fin for
installed in every unit
maximum heat transfe
ملخص المحتوى في الصفحة رقم 2
2AC13 Split System Air Conditioner 13 Model Number Guide 2 AC 13 B 24 P - 1 A Minor Revision Code Refrigerant – 2 = R22 Major Revision Code AC = Condenser Voltage 13 - 13 SEER Nominal P - 208-230v/60hz Single Phase BC = Wire Guard + 76dBA Nominal Capacity LC = Louvered + 76dBA 24 - 24,000 Btuh B = Wire Guard L = Louvered Electrical and Physical Data Maximum Compressor Fan Motor Weight (lbs.) Min. Over Refrig. Voltage/ Hz/ Voltage Rated Locked Charge Model
ملخص المحتوى في الصفحة رقم 3
2AC13 Split System Air Conditioner 13 Cooling Performance with Evaporator Coils Indoor Refrigerant Refrigerant Indoor Model Metering Connection Line Size Device Rated Rated Outdoor SEER EER ARI Sensible CFM Outdoor Indoor Model Optional 1 Capacity Capacity Req'd Piston or Field Factory Field 2 Indoor Installed TXV Installed TXV Installed Orifice Orifice E(C,M,U)1P18N(A,B) E(C,M,U)2T18N(A,B) 13.00 11.00 17,000 12,200 550 3/8 3/8 3/4 3/8 .05
ملخص المحتوى في الصفحة رقم 4
2AC13 Split System Air Conditioner 13 Cooling Performance with Air Handlers and Furnaces (18) Indoor Refrigerant Refrigerant Indoor Model Metering Connection Line Size Device Variable Rated Rated Outdoor Speed SEER EER ARI Sensible CFM Model Outdoor Indoor 1 Optional Furnace Capacity Capacity Req'd Piston or Field Factory Field 2 Indoor Installed TXV Installed TXV Installed Orifice Orifice RBCS2M18C****P RBCS2M18C****T --- 13.00 12.00
ملخص المحتوى في الصفحة رقم 5
2AC13 Split System Air Conditioner 13 Cooling Performance with Air Handlers and Furnaces (24) Indoor Refrigerant Refrigerant Indoor Model Metering Connection Line Size Device Variable Rated Rated Outdoor Speed SEER EER ARI Sensible CFM Model Outdoor Indoor 1 Optional Furnace Capacity Capacity Req'd Piston or Field Factory Field 2 Indoor Installed TXV Installed TXV Installed Orifice Orifice RBCS2M24C****P RBCS2M24C****T --- 13.00 11.50
ملخص المحتوى في الصفحة رقم 6
2AC13 Split System Air Conditioner 13 Cooling Performance with Air Handlers and Furnaces (30) Indoor Refrigerant Refrigerant Indoor Model Metering Connection Line Size Device Variable Rated Rated Outdoor Speed SEER EER ARI Sensible CFM Model Outdoor Indoor 1 Optional Furnace Capacity Capacity Req'd Piston or Field Factory Field 2 Indoor Installed TXV Installed TXV Installed Orifice Orifice RBCS2M30C****P RBCS2M30C****T --- 13.00 11.50
ملخص المحتوى في الصفحة رقم 7
2AC13 Split System Air Conditioner 13 Cooling Performance with Air Handlers and Furnaces (36, 42, 48, 60) Indoor Indoor Refrigerant Refrigerant Metering Model Connection Line Size Device Variable Rated Rated Outdoor Speed SEER EER ARI Sensible CFM Outdoor Indoor Model 1 Optional Furnace Capacity Capacity Req'd Piston or Field Factory Field 2 Indoor Installed TXV Installed TXV Installed Orifice Orifice RBCS2M36C****P RBCS2M36C****T
ملخص المحتوى في الصفحة رقم 8
2AC13 Split System Air Conditioner 13 Cooling Performance with Extended Ratings Outdoor Temp - DB˚F Indoor Outdoor Temp Indoor Model 65 82 95 105 115 Model DB/WB ˚F Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW 75/63 16,900 .71 1.25 16,100 .76 1.42 15,700 .78 1.49 15,000 .81 1.55 13,800 .82 1.60 2AC13**18P E*1P19 80/67 18,200 .67 1.29 17,400 .71 1.47 17,000 .73 1.55 16,100 .76 1.61 14,900 .76 1.67 85/71 19,400 .65 1.34 18,500 .69 1.53 18,000 .71 1.61 17,100 .74 1.68