ملخص المحتوى في الصفحة رقم 1
Portable Air Conditioner
AP12000HS
Owner’s Manual
For more information on other great EdgeStar products on the web, go to http://www.edgestar.com
ملخص المحتوى في الصفحة رقم 2
Important Safety Information Improper handling can cause serious damage to the appliance and/or to the user. This portable air conditioner is not intended for use by children. Children should be supervised to ensure that they do not play with this product. Electrical Safety This unit is designed for indoor use only. Do not use the unit in extremely humid or wet environments. Do not wet the housing or control panel. Do not pull the unit by the cord. Always turn the unit
ملخص المحتوى في الصفحة رقم 3
Table of Contents IMPORTANT SAFETY INFORMATION ................................................................. I INTRODUCTION ................................................................................................... 1 PARTS IDENTIFICATION ..................................................................................... 2 BACK VIEW .......................................................................................................... 2 FRONT VIEW ........................
ملخص المحتوى في الصفحة رقم 4
Introduction Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We believe that your purchase of this product opens a relationship between you and EdgeStar. We will provide the customer support needed to nurture that relationship. This manual contains important information regarding the proper installation, use and maintenance of your portable air conditioner. Following this manual will ensure that your product will work at its peak performa
ملخص المحتوى في الصفحة رقم 5
Parts Identification Front View Control Panel Front Air Vent Handle Caster Pre-filter Back View Air Intake Exhaust Outlet Power Cord Drain Valve EdgeStar Portable Air Conditioner 2
ملخص المحتوى في الصفحة رقم 6
Installing the Carbon Filter Your portable air conditioner ships with a pre-filter and an activated carbon filter. The carbon filter will help remove contaminates and odors from the air. It is recommended you replace the carbon filter every two to three months, or as needed. It is necessary to clean the pre-filter periodically. Follow the steps below to install the carbon filter: CAUTION: Never operate the air conditioner without the pre-filter attached.
ملخص المحتوى في الصفحة رقم 7
20” Window Kit Installation Instructions You must vent your portable air conditioner when running in it Preparations for installing cooling mode. Your unit includes a window exhaust kit that can be the window kit used to vent the unit out a window. Before you begin, make sure you have all the parts necessary for installation. Window Kit Parts List: NOTE: Exhaust Covers 4 Screws 1 Grated Adapter may be attached to the Grated Adapters. You may need to twist and pull
ملخص المحتوى في الصفحة رقم 8
Installing the grated adapter 1. Insert the round grated adapter through the back grooved side of the window kit plate with hole. 2. Secure the grated adapter by fastening the screws from flat side of the window kit plate to the holes on the grated adapter. 5
ملخص المحتوى في الصفحة رقم 9
Installing the window plates 3. Open your window and place the window kit with grooved side facing outward on the window sill. Then, slide the window kit plate to fit the width of the window. You can use screws to secure the window kit plate from sliding. 4. Lower the window to secure the window kit in place. You CAUTION: Secure your may need to use duct tape to better secure the window
ملخص المحتوى في الصفحة رقم 10
20” Attaching the duct connectors to the exhaust hose A. B. 5. Attach the connectors to the hose: A. Extend the ends of the exhaust hose B. Thread the duct connector on by turning it clockwise until it stops. 6. Roll the unit towards the window kit. Leave a space that is at least 20 inches to the wall. 7
ملخص المحتوى في الصفحة رقم 11
Connecting the duct connector to the unit 7. Align the slots on the duct connector to the tabs and snap into the back of the unit. Connecting the duct connector to the grated adapter 8. Align the slots on the duct connector to the tabs on the grated adapter and snap in place. After you have installed the exhaust hose and window kit, you can plug in your portable air conditioner
ملخص المحتوى في الصفحة رقم 12
Your portable air conditioner is designed to exhaust condensate Notes about the Exhaust water that is collected from the air. This water, in either gaseous or hose droplet form, will be expelled out the exhaust port of the unit. Please take this into account when deciding how to vent it. 1. The exhaust hose supplied with the portable air conditioner can be extended up to 48 inches; however for maximum efficiency, use the shortest length possible. 2. Try to prevent any kinks or ben
ملخص المحتوى في الصفحة رقم 13
Control Panel Overview Indicator Lights LCD Display Cooling High Dehumidify Medium WATER Fan Only Low Timer POWER Mode Speed Timer Power Button Timer Button Mode Button Up Button Down Button Speed Button Infrared Sensor Button Function Power Powers the unit on or off. Mode Changes between cool, dehumidify heat and fan modes. The indicator light will turn on next to the mode you set. Heating mode will have a red indicator light Speed Sets the fan speed. The High, Medium, or Low indicato
ملخص المحتوى في الصفحة رقم 14
Operating the Control Panel Use the Power button to turn the portable air conditioner on and off. Power By default when you first use the power button, the unit will begin to operate in cooling mode. The unit will remember the last used mode/settings if you shut down and restart. Auto-Restart: If power to the unit is interrupted, the air conditioner will restart itself in its last used mode/settings once power is restored. The compressor will restart after 3 minutes. Cooling
ملخص المحتوى في الصفحة رقم 15
Fan Only mode is used to circulate the air in your room. No Fan Only Mode temperature setting is needed. To operate the unit in Fan Only mode: 1) Make sure the power cord is plugged into a power outlet. 2) Press the Power button. 3) Press the Mode button until the LED indicator next to “Fan Only” NOTE: Fan Only mode lights up. does not require that the 4) Press the Speed button to select the fan speed. You can choose exhaust hose be attached. between High, Medium and Low. The
ملخص المحتوى في الصفحة رقم 16
Using the Remote Control The remote control can be used instead of the control panel to remotely operate your portable air conditioner. The functions on the remote are the same as on the control panel. Power Button Mode Button Speed Button Up and Down Buttons Timer Button NOTES: Be careful not drop the remote control. Do not place the remote control in a location exposed to direct sunlight. Button Function Power Powers the unit on or off. Mode Changes between cool, dehumidify
ملخص المحتوى في الصفحة رقم 17
Energy Saving Guide Read and follow the guide below to get the best performance and efficiency from your portable air conditioner: Do not cover the air outlet (exhaust) while in use. Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake. Minimize the length of the exhaust hose. Make sure the exhaust hose is as straight as possible and avoid kinks or bends. Keep curtains, blinds or drapes closed during the sunniest part of the da
ملخص المحتوى في الصفحة رقم 18
Maintenance Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning. Cleaning the unit Use a soft dry cloth to wipe the body clean. If necessary, use lukewarm water to dampen a cloth to clean the unit. Use a soft bristle brush to clean between the vents. Carefully use a vacuum cleaner to clean the condenser coils Never use abrasive chemi
ملخص المحتوى في الصفحة رقم 19
Troubleshooting Follow the troubleshooting guide below to resolve common issues. Issue Possible Cause Solution My air conditioner is Unit is not receiving Make sure the unit is not functioning at all power plugged in LCDI power cord is Press the Reset button tripped on the LCDI cord Insufficient power Move the unit to another outlet. Check your circuit breaker. (Refer to the rating label on the back of the unit to determine the Amperage draw) Water reservoir is full Drain the un
ملخص المحتوى في الصفحة رقم 20
Troubleshooting continued Issue Possible Cause Solution My air conditioner is Unit is not operating in Set the unit to be in not cooling at all cooling mode cooling mode, and lower the set temperature (pg. 11) The compressor is not The compressor may on take up to 3 minutes to turn on, or longer if it is too warm The ambient Lower the room temperature is too high temperature to be below 90°F degrees The filter may be dusty Clean the filters. NOTE: If the ambient or blocked (pg. 1