ملخص المحتوى في الصفحة رقم 1
STUDIO KIT
STUDIO SDI KIT
INSTRUCTIONS
KA-F5602U
KA-F5603U
BREAKER
*Illustration with optional lens
PROMPTER
RM
OUTPUT DC INPUT
and viewfinder attachments.
This instructions book is made from 100 %
For Customer Use:
recycled paper.
Enter below the Serial No. which is
located on the cabinet. Retain this
information for future reference.
Thank you for purchasing this JVC product.
Before operating this unit, please read the
Model No. KA-F5602U/KA-F5603U
instructions
ملخص المحتوى في الصفحة رقم 2
1. Read all of these instructions. 2. Save these instructions for later use. 3. All warnings on the product and in the operating instructions should be adhered to. 4. Unplug this appliance system from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. 5. Do not use attachments not recommended by the appliance manufacturer as they may cause hazards. 6. Do not use this appliance near water – for example, near a bathtub, washb
ملخص المحتوى في الصفحة رقم 3
SAFETY PRECAUTIONS (FOR USA AND CANADA) CAUTION ATTENTION RISK OF ELECTRIC SHOCK RISQUE D’ELECTROCUTION DO NOT OPEN NE PAS OUVRIR ATTENTION: POUR EVITER TOUT RISQUE D’ELECTROCUTION CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, NE PAS OUVRIR LE BOITER. DO NOT REMOVE COVER (OR BACK). AUCUNE PIECE INTERIEURE N’EST NO USER-SERVICEABLE PARTS INSIDE. A REGLER PAR L’UTILISATEUR. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL SE REFERER A UN AGENT QUALIFIE EN CAS DE PROBLEME. Le symbole de l’éclair à l
ملخص المحتوى في الصفحة رقم 4
SAFETY PRECAUTIONS (FOR EUROPE) WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. This unit should be used with 12 V DC only. CAUTION: To prevent electric shocks and fire hazards, do NOT use any other power source. Note: The rating plate (serial number plate) is on this unit. CAUTION To prevent electric shock, do not open the cabinet. No user serviceable parts inside. Refer servicing to qualified service personnel. 4
ملخص المحتوى في الصفحة رقم 5
This equipment is in conformity with the provisions and protection requirements of the corre- sponding European Directives. This equipment is designed for professional video appliances and can be used in the following environments: 5 Residential (including both of the location type class 1 and 2 found in IEC 1000-2-5) 5 Commercial and light industrial (including, for example, theatres) 5 Urban outdoors (based on the definition of location type class 6 in IEC 1000-2-5) In order to keep the best p
ملخص المحتوى في الصفحة رقم 6
Thank you for purchasing this KA-F5602U / KA-5603U Studio Kit. This product is a kit meant for converting JVC’s KY-F560 video camera into a studio camera. Model designation may differ depending on whether the Studio Kit is equipped with a SDI (Serial Digital Interface) terminal. Model SDI Output Terminal KA-F5602U Nil KA-F5603U Yes Main Features ● Equipped with analog 26P camera connector Connecting to Remote Control Unit RM-P210, which is sold separately, this unit could be controlled from up
ملخص المحتوى في الصفحة رقم 7
Contents Getting Started Accessories ........................................................................................................ 8 Related Products used in Conjunction with this Unit .......................................... 8 Precautions......................................................................................................... 9 Regarding Gain-lock Signal and adjustment of System Phase .......................... 9 Part Names and Functions ............................
ملخص المحتوى في الصفحة رقم 8
Getting Started Accessories Studio Kit main body Screw - 1 piece:Use for securing KY-F560 camera on the Studio Kit. BREAKER Instructions (this booklet) PROMPTER OUTPUT RM DC INPUT Relay board Related Products used in Conjunction with this Unit ● Color video camera......................... KY-F560 ● 4-inch Viewfinder ............................ VF-P400 ● Remote Control Unit ....................... RM-P210 ● Intercom Headset ........................... KA-310U ● 26 Pin Camera Cable ........
ملخص المحتوى في الصفحة رقم 9
Precautions In order to ensure that this unit could serve Earthing the INTERCOM G(GND) terminal you longer, avoid storing or using it at the is recommended as noises may be induced following places. depending on the intercom headset used. Extremely hot or cold places Use only the specified standard length Places with strong vibration camera cable. Otherwise, the cable com- Dusty places pensation may be insufficient. High humidity places In the vicinity of strong noise sources D
ملخص المحتوى في الصفحة رقم 10
Getting Started Part Names and Functions 1 [RM] RM Multi-pin Connector (26 Pin) Connect to Remote Control Unit RM-P210 by using the 26 pin camera cable. @ # In addition, power is supplied to the this unit and the camera via this connector from the remote control unit. Note Besides Composite video signal, other types of camera video signals which could be output from the output terminal of RM-P210 include RGB component, Y/Cb/Cr component and YC separate signal. The output signal could be se- lect
ملخص المحتوى في الصفحة رقم 11
Part Names and Functions (continued) 5 [INCOM MIC] Intercom Mic [CARBON/ 9 Relay Board DYNAMIC] Switch This board is meant for connecting to KY- Use for selecting the type of intercom F560 camera. This is to be inserted into headset microphone to be used. the slot at the rear of KY-F560. [CARBON] : Choose this setting if car- 0 [SDI OUT] SDI Output Terminal...Only bon type microphone is to for KA-F5603U be used. Camera video is output in the form of SDI [DYNAMIC] : Choose this setting if dy- sig
ملخص المحتوى في الصفحة رقم 12
Getting Started Part Names and Functions (continued) BREAKER PROMPTER RM OUTPUT DC INPUT ^ % $ & $ [PROMPTER OUTPUT] Prompter ^ [BREAKER] Breaker Switch Output Terminal (BNC) Breaker switch will trip and cut off the Signal (prompter video signal) inputted power if the power consumed is higher into the [AUX] input terminal of the remote than the rated capacity. If the breaker control unit will be outputted from this ter- switch trips, confirm that there are no ab- minal via the RM multi-pin conne
ملخص المحتوى في الصفحة رقم 13
Installation System Viewfinder VF-P400 AC power adapter AA-P250 VC-710 (5 m) 4P 4P Studio kit/Studio SDI kit KA-F5602U/KA-F5603U Color video camera Lens KY-F560 Headset KA-310U COLOR VIDEO CAMERA KY-F560 BREAKER PROMPTER OUTPUT RM DC INPUT [PROMPTER OUTPUT] SDI output (only KA-F5603U) connector [INTERCOM] connector [DC INPUT] connector SDI input RM multi-pin connector SDI compatible video equipment 26Pin camera cable Headset Monitor VC-P110 (5 m) KA-310U VC-P112 (20 m) VC-P113 (50 m) VC-P114 (10
ملخص المحتوى في الصفحة رقم 14
Installation Installation Procedures 1. Mounting KY-F560 Camera on this Unit. 2. Mounting the Lens onto the Camera. 3. Mounting this Unit onto the Tripod. 4. Mounting VF-P400 4-inch Viewfinder on this Unit. Mounting KY-F560 Camera on this Unit 1. 1. Preparations to be done on KY-F560 cam- era. Screw Å ● If the lens is attached to KY-F560 cam- era, remove and place it aside. ● Attached the camera mounting bracket at the bottom of the camera. ● Remove 2 screws Å from the rear of Slot cover the cam
ملخص المحتوى في الصفحة رقم 15
Mounting KY-F560 Camera on this Unit (continued) 3. 3. Place the camera on top of the camera mounting frame and use the screw Ç pro- vided to secure the camera to the base of the frame. Use the camera mounting bracket screw hole to secure the camera. Mounting bracket 4. After the camera mounting frame is in- serted into this unit, secure it by screwing back the 2 screws ı which were taken Screw Ç out earlier in above-mentioned step 2.. Camera mounting frame Notes 4. ● Please remove the camera le
ملخص المحتوى في الصفحة رقم 16
Installation Mounting the Lens onto the Camera Please refer to KY-F560 instruction manual on mounting the lens. ● When using the under-mentioned types of lens, lens cable ECE-R22 which is sold sepa- rately must be used. (Please consult your local JVC authorized service agent for details of the cable to be used.) S17 x 6.6 BRM(FUJINON) YH16 x 7K12U(CANON) ● Use the cable clamp to secure the lens cable to this unit. Cable clamp ECE-R22 Lens cable Lens cable Mounting this Unit onto the Tripod Mount
ملخص المحتوى في الصفحة رقم 17
Mounting VF-P400 4-inch Viewfinder on this Unit VF-P400 4-inch Viewfinder Lock lever Viewfinder holder 3. 1. Viewfinder Cable 2. 4. Viewfinder terminal 1. Loosen the viewfinder lock lever by turning it anti-clockwise. 2. Slide the viewfinder forward along the viewfinder holder guide on top of this unit. 3. Turn the viewfinder lock lever clockwise to lock it. 4. Plug the viewfinder cable connector into this unit’s viewfinder terminal. Note When “ASPECT RATIO” item under the “SYSTEM” menu screen o
ملخص المحتوى في الصفحة رقم 18
Connecting RM-P210 Connecting to Remote Control Unit RM-P210 26 Pin camera Headset cable KA-310U REMOTE CONTROL UNIT RM-P210 TALLY CALL FULL AUTO F1 F3 MENU/SHUTTER GAIN PAINT WHITE AUTO MASTER BLACK IRIS POWER AW BARS SHUTTER STEP W.BAL MENU SET HIGH B I SHUTTER VARIABLE MID A BARS F2 F4 MENU PUSH-ON PUSH-ON R B PRESET MANU AUTO REMOTE LENS LOW GAIN O INTERCOM DOWN UP DOWN UP LEVEL CLOSE OPEN GENLOCK IN VIDEO OUT Headset DC IN POWER SEE INST KA-310U Remote control unit RM-P210 INCOM MIC VF ON
ملخص المحتوى في الصفحة رقم 19
Connecting to Remote Control Unit RM-P210 (continued) GENLOCK IN VIDEO OUT Switch setting DC IN POWER Rear view of SEE INST ● Set the [CARBON/DYNAMIC] switch according to this unit INCOM MIC VF the type of intercom headset microphone to be ON CARBON OFF DYNAMIC INTERCOM used. (If JVC Headset KA-310U is connected, INCOM LEVEL CALL MIN MAX choose the [CARBON] setting.)) ● Set the [INCOM MIC ON / OFF] switch depending [CARBON/DYNAMIC] on whether headset microphone will be used. If the switch sw
ملخص المحتوى في الصفحة رقم 20
Connecting RM-P210 Notes to be taken when operating RM-P210 When using RM-P210 menu to carry out the setting of KY-F560, some items of RM-P210 menu setting may not be consistent with the operations of KY-F560. RM-P210 Menu Operation of KY-F560 No Item Variable Value KNEE point may vary as follows: 4G “PROCESS” 10 NORMAL : 100 % (Maximum level) screen “KNEE POINT” NORMAL –10 : 80 % (Minimum level) (KNEE POINT setting Level will change by 5 % with every –10 when AUTO KNEE is 2-step adjustment on