ملخص المحتوى في الصفحة رقم 1
PRECAUTIONS FOR PROPER USE OF AIR CONDITIONER
Please observe the following instructions.
1. Operate the Selector Switch to run or stop the unit.
- Do not use Main Power Switch or Auxiliary Power Switch to operate unit.
2. Do not stick anything into the air outlet or inlet.
- It is dangerous and it can cause injury or damage.
3. Avoid exposing your body directly to a continuous cool air - flow for long periods.
- It is not good for your health.
4. Do not pour water on the unit to clean it.
- It i
ملخص المحتوى في الصفحة رقم 2
TABLE OF CONTENTS 1. GENERAL SPECIFICATIONS....................................................................................................2 2. INSTALLATION INSTRUCTIONS ............................................................................................3~8 • WINDOW REQUIREMENTS • BASIC TOOLS NEEDED • SAFETY INSTRUCTIONS • BEFORE INSTALLATION • STEP1-PREPARE COMPONENTS FOR INSTALLATION • STEP2-PREPARE WINDOW FOR INSTALLATION • STEP3-PREPARATION OF CHASSIS • STEP4-PLACING CHASSIS • ST
ملخص المحتوى في الصفحة رقم 3
INSTALLATION INSTRUCTIONS • WINDOW REQUIREMENTS These instructions are provided for a standard double hung window or mobile home double hung window installation in windows 27.5 inch (699mm) to 36 in (914mm). The upper and lower sash must open sufficiently to allow a clear vertical opening of 15 in (381mm) from the bottom of the sash to the window sill. 27.5" To 36" Select a centrally located window on the side of the room that 14.9" MIN 15" MIN receives the least direct sunlight. There should be
ملخص المحتوى في الصفحة رقم 4
• SAFETY INSTRUCTIONS (CONTINUED) The receptacle should be an individual branch circuit used only for this air conditioner. Be sure the electrical service is adequate for the model air conditioner you have chosen. The complete electrical rating of your air conditioner is stated on the name plate located at the unit’s side. Be sure the plug receptacle is close enough for the power cord to reach it. WARNING : An extension cord should not be used with your air conditioner! To minimize shock and fir
ملخص المحتوى في الصفحة رقم 5
• Step 1 - Prepare Components For Installation Parts for installation are as follows; • SCREW TYPE • Sill Bracket (2 pieces) Type A Type B Type C Type D Type E • Window Kit Left side (Frame ‘L+Shutter) - (1 piece) • Window Kit Right side (Frame ‘R+Shutter) - (1 piece) • Sash Bracket (1 piece) • DRAIN, DRAIN seal SHAPE • Frame Guide Lower - (2 pieces) • Levelling Screw (Machine M8x45) - (2 pieces) • 1 inch Screw (M5x30) - (4 pieces) • 5/8 inch Screw - (M4x16) - (8 pieces) SPEC M8 x 45 M5 x 30 M4
ملخص المحتوى في الصفحة رقم 6
4. Disassemble Front Grille from Chassis. – Front Grille and chassis are fixed with snap-fit. 1) Release right-lower snap-fit. – Push the right lower side of chassis to the left, with pushing left side of Front Grille to the right until the snap-fit is released. Push Push 2) Release left-lower snap-fit. – Push the left-lower side of chassis to the right, with pushing right side of Front Grille to the right until the snap-fit is released. Push Push 3) Pull lower side of the Front Grille until it
ملخص المحتوى في الصفحة رقم 7
• Step 4 - Placing Chassis FRAME Screw (Type E, both side) Guide Lower 1. Insert narrow side of ‘Frame Guide Lower’ to rectangle holes located in bottom of chassis, and fasten it with Screw (Type E). 2. Insert Window Kit Frames to Top Guide and Lower Guide. 3. Fasten Shutter to side holes of Chassis with six Screws (Type E). 4. Place the chassis on the window sill and align it with Sill Bracket and sill with Lower Frame Guide and locate window sash to Top Frame Guide. (check the end of chassis
ملخص المحتوى في الصفحة رقم 8
• Step 6 - Recheck Installation To be sure you have correctly installed your Room Air Conditioner, review the steps and make sure all of the parts are securely fastened in the window as the instructions show. A tight seal is essential. Read through the Use & Care manual to become familiar with the operation of your room air conditioner. CAUTION Do not lift window sash without holding the unit. The window sash helps keep the unit in the window. Exercise caution when opening the window. Failure t
ملخص المحتوى في الصفحة رقم 9
NAMES OF MAJOR COMPONENTS • DWC-100C / DWC-121C / DWA-122C / DWA-150C / DWA-151C 9 3 3 10 7 7 11 4 4 8 8 2 2 1 5 6 1 5 6 • DWC-100CS / DWC-121CS / DWA-122CS / DWA-150CS / DWA-151CS 9 3 3 10 7 7 11 4 4 8 8 2 2 1 5 6 1 5 6 12 12 NO PART NAME NO PART NAME 1 AIR FILTER 7 BLADE HORIZENTAL 2 GRILLE FRONT 8 AIR VENT 3 CABINET 9 FRAME GUIDE TOP 4 BLADE VERTICAL 10 FRAME WINDOW KIT 5 KNOB THERMOSTAT 11 SHUTTER WINDOW 6 KNOB SELECTOR 12 AUTO LOUVER S/W (DWC-100CS/DWC-121CS/DWA-122CS/DWA-150CS/DWA-151CS) 9
ملخص المحتوى في الصفحة رقم 10
OPERATING INSTRUCTIONS NOTE • FOR MOST ECONOMICAL USE 1. Properly control the room temperature. 2. Avoid the unit being exposed to direct sunlight. Keep direct sunlight from the room. 3. Do not leave doors and windows open. • FAN & COOLING CONTROL The Fan Control Selector Switch has six positions. Choose one of the speed settings by rotating the fan control Selector Switch to the appropriate position. CAUTION When the air conditioner has been performing its cooling operation and is turned “OFF”
ملخص المحتوى في الصفحة رقم 11
GENERAL INFORMATION • CHANGING AIR FLOW DIRECTION Air flow deflectors divert air from center flow to left or right and up or down. Adjust deflectors for desired air flow pattern. AUTO SWING (DWC-100CS, DWC-121CS, DWA-122CS, DWA-150CS, DWA-151CS) When the auto louver switch is turned to “ON” position, the vertical louvers AUTO SWING automatically move right and left. Thus, you can obtain comfortable cooling. The vertical louvers may be stopped at any position when the auto louver ON / OFF swit
ملخص المحتوى في الصفحة رقم 12
CARE AND MAINTENANCE CAUTION To avoid death or personal injury due to electrical shock, turn fan control OFF and unplug power cord before cleaning or performing maintenance. After cleaning or performing maintenance, reconnect power. • AIR FILTER Clean the air filter, which removes dust inside the room. It should be washed at least once every week during operation. 1. Remove the Air Filter from the front grill by pulling to right. 2. Clean Air Filter with a vacuu
ملخص المحتوى في الصفحة رقم 13
ELECTRICAL REQUIREMENTS • ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code. WARNING : To avoid death, personal injury or properly damage due to electr
ملخص المحتوى في الصفحة رقم 14
BEFORE CALLING FOR SERVICE When you find something wrong with your room air conditioner, please carefully check the following items. If you are unable to find the cause of trouble, contact your service dealer. Difficulty Possible Cause Suggested Solution • Air conditioner does • No power to unit. • Set Fan Control Select to not operate. position other than "OFF". • Confirm power cord is plugged in. • Verify main power switch (main circuit breaker) or fuse of the unit is good. • Little or no coo
ملخص المحتوى في الصفحة رقم 15
Limited Warranty DAEWOO ELECTRONICS CORPORATION OF AMERICA warrants the following window room air-conditioner to be free from defective material and workmanship and agrees to remedy any such defect or to furnish a new part (at the Company’s option) in exchange for any part of any unit of its manufacture which under normal installation, use and service disclosed such defect, provided the unit is delivered by the owner to store or dealer where purchased or Daewoo authorized service center. To esta
ملخص المحتوى في الصفحة رقم 16
ROOM AIR CONDITIONER USE & CARE MANUAL WINDOW TYPE ROOM AIR CONDITIONER MODEL #: DWC-100C, DWC-100CS DWC-121C, DWC-121CS DWA-122C, DWA-122CS DWA-150C, DWA-150CS DWA-151C, DWA-151CS R C UL and US CUL listed LISTED Please read carefully and thoroughly this manual before operating the unit. If you still have any difficulties or problems, consult your dealer for help or ELECTRONICS. Please keep this manual well. W1