ملخص المحتوى في الصفحة رقم 1
Henkel, Inc.
P.O. Box 1322
Hammond, LA
70404
(985) 345-2171
www.keenovens.com
ملخص المحتوى في الصفحة رقم 2
Henkel, Inc. P.O. Box 1322 * Hammond, Louisiana * 70404 * (985) 345-2171 www.keenovens.com Model KHTF-600 Re-bake Flux Oven Installation Instructions & Repair Parts List One Year Limited Warranty Henkel, Inc. warrants its products against defects in material and workmanship. Henkel, Inc. will either repair or replace without charge any properly installed product which fails under normal operating conditions within one year from date of installation, provided it is
ملخص المحتوى في الصفحة رقم 3
Recommended Spare Parts When it is critical to have continuous operation of this unit; we suggest having the following spare parts on hand: 240 V –1 Set of Elements, 1 Contactor 480 V – 1 Set of Elements, 1 Contactor, 1 Transformer General Information The KHTF-600 is the most energy efficient flux oven on the market, using one- third the electricity and one half the stabilizing time. The bottom unloading design and slide valve allows for easy dispensing of flux. The unit is m
ملخص المحتوى في الصفحة رقم 4
• Use special care when moving heavily loaded units. • Do not store combustible material on or around the unit. • Do not operate this unit empty. • When using the unit at a distance where an extension cord becomes necessary, a 3-conductor grounding cord of adequate size must be used for safety, and to prevent loss of power and overheating. Use only a UL listed extension cord suitable for outdoor use. Make certain wire size is large enough for A/C amperage rating of unit. Operation
ملخص المحتوى في الصفحة رقم 5
3. Check output side of fuse block for proper voltage. If fuses are bad, inspect oven wiring and components for damage. Replace fuses. 4. Check input and output voltages on temperature controller for proper voltage. If input voltage is not present, check wiring. If input voltage is present and there is no output voltage, replace or repair controller. 5. If output voltage is present, check for voltage at contactor coil. If voltage is not present, check wiring. If voltage is present at coil
ملخص المحتوى في الصفحة رقم 6
Element Cover Thermowell Control Box Elements Changing the Elements Changing the Controller CHANGING THE CONTROLLER 1. Disconnect from the power source and remove cover plate from control box. 2. Tag and remove leads from back of controller. 3. The controller is held in place by mounting brackets on either side of controller. From the rear, loosen mounting bracket screws, remove mounting brackets and slide controller from control b
ملخص المحتوى في الصفحة رقم 7
KHTF- 600 ACCESSORIES LIST ** Please state model number and serial number and specify voltage and wattage when ordering repair parts, spare parts, or accessory parts. All necessary attaching hardware is supplied with each part ordered. (Item numbers refer to pictorial drawings below for repair parts.) Model KHTF-600 Repair Parts List ITEM # QUANTITY DESCRIPTION PART NUMBER 5 8 Element Assembly 240V/1000W 301026 480V/1000W 301029 3 1 Power Cord 240 V