VSP-V-1101A
Issue 9
V-1101A
ONE ZONE ONE-WAY PAGE ADAPTER
INTRODUCTION
The V-1101A is a One Zone One-way Page Adapter
for use with most electronic or electromechanical
telephone systems.
These instructions contain the specifications and
information necessary to install, operate, and maintain
the One Zone One-way Page Adapter.
This paging unit has received an FCC type KX
registration and is designed to be used with FCC
registered key telephone systems.
In accordance with FCC rules with applicab
ملخص المحتوى في الصفحة رقم 2
VALCOM Electronic Key or PABX Access ONE-WAY PABX When using the V-1101A with an electronic key AMPLIFIED SPEAKER ASSEMBLIES system or PABX, the following equipment will be TRUNK required: V-1101A PORT • (1) V-1101A One Zone One-way Page Adapter • (1) C. O. Line Card (electronic key system) or (1) Loop Trunk Card • Valcom one-way amplified speaker assemblies (quantity and style determined by specific installation) 24VDC • A –24 Vdc power supply (size and quantity POWER SUPPLY determined by numbe
ملخص المحتوى في الصفحة رقم 3
NOTE: The intercom used MUST supply a holding INSTALLATION ground or page control lead to properly operate the General V-1101A. A page control lead is a lead that supplies These instructions cover the installation procedures Ground whenever the intercom is in use, and which is for the Valcom V-1101A and any associated Open when the intercom is idle. Contact the equipment. Please consult practices for other manufacturer of your intercom if you have questions manufacturer's equipment if any ot
ملخص المحتوى في الصفحة رقم 4
__ (c) On one column of the block, completely __ (c) If no relay is heard: punch down a 25 pair cable. The other end __ (1) Unplug power supply. of the cable should have a female amphenol __ (2) Verify the V/BR and V/S pairs are connector. properly connected at the __ (d) Plug the amphenol connector into the punch-down block and in the V-1101A. amphenol. __ (e) Mark the punch down block as shown in __ (3) Return to step 2, and verify all Figure 2. connections. __ (d) If a relay is
ملخص المحتوى في الصفحة رقم 5
FIGURE 2 AB C D E F TIP 26 T W/BL RING 1 R BL/W HOLDING GROUND 27 H W/O 2 ICM START SIG O/W 28 GROUND START DIR W/G 3 G/W 29 CT2 W/BR NORMALLY OPEN CONTACT 4 CT2 BR/W BATTERY FEED TIP 30 BFT W/S 5 BATTERY FEED RING BFR S/W 31 A1 R/BL NORMALLY OPEN CONTACT 6 A1 BL/R 32 NORMALLY OPEN CONTACT A2 R/O 7 A2 O/R 33 MUSIC INPUT MT R/G 8 MR G/R 34 PG R/BR PAGE OUT 9 OUT BR/R 35 R/S 10 S/R 36 BK/BL 11 BL/BK 37 BK/O 12 O/BK 38 BK/G 13 G/BK 39 BK/BR 14 BR/BK 40 BK/S 15 S/BK 41 Y/BL 16 BL/Y 42 Y/O 17 O/Y 43
ملخص المحتوى في الصفحة رقم 6
PABX LOOP TRUNK PORT PUNCHDOWN OR ELECTRONIC KEY BLOCK V-1101A SYSTEM LINE BUTTON TIP (W/BL) 26 T (W/BL) RING (BL/W) 1 R (BL/W) (W/O) 27 H (W/O) (W/G) 28 DIR (W/S) 30 (W/G) (S/W) 5 BFT (W/S) (R/BL) 31 BFR (S/W) (BL/R) 6 A1 (R/BL) ONE-WAY A1 (BL/R) AMPLIFIED SPEAKER (R/G) 33 MT (R/G) ASSEMBLIES (G/R) 8 MR (G/R) (R/BR) 34 PG (R/BR) (BR/R) 9 -24VDC POWER SUPPLY OUT (BR/R) (V/BR) 49 AG (V/BR) A GROUND (BR/V) 24 AB (BR/V) A BATTERY (V/S) 50 BG (V/S) B GROUND (S/V) 25 BB (S/V) B BATTERY FIGURE 3 ELECT
ملخص المحتوى في الصفحة رقم 7
PUNCHDOWN 1A2 TELEPHONES BLOCK V-1101A PAGE BUTTON TIP (W/BL) 26 T (W/BL) RING (BL/W) 1 R (BL/W) LAMP H (W/O) LGND DIR (W/G) BFT (W/S) BFR (S/W) A1 (R/BL) ONE-WAY A1 (BL/R) AMPLIFIED SPEAKER POWER SUPPLY A2 (R/O) ASSEMBLIES (R/O) 32 A2 (O/R) (O/R) 7 MT (R/G) PG (R/BR) LAMP GROUND MR (G/R) OUT (BR/R) LAMP BATTERY (V/BR) 49 AG (V/BR) A GROUND (BR/V) 24 AB (BR/V) A BATTERY (V/S) 50 BG (V/S) B GROUND (S/V) 25 BB (S/V) B BATTERY FIGURE 4 1A2 KEY SYSTEM LINE BUTTON ACCESS (2) go back to ste
ملخص المحتوى في الصفحة رقم 8
INTERCOM BLOCK V-1101A TIP (W/BL) 26 T (W/BL) RING (BL/W) 1 R (BL/W) PC (W/O) 27 H (W/O) SIG (O/W) 2 SIG (O/W) RET MT (R/G) MR (G/R) AUDIO SIG ONE-WAY AUDIO GND AMPLIFIED SPEAKER ASSEMBLIES PG (R/BR) AUD GND OUT(BR/R) AUD SIG (V/BR) 49 AG(V/BR) A GND (BR/V) 24 AB(BR/V) A BATT (V/S) 50 BG (V/S) B GND (S/V) 25 BB (S/V) B BATT POWER SUPPLY FIGURE 5 1A2 INTERCOM ACCESS __ 6. Connect Tip of the one-way amplified WIRING INSTRUCTIONS: speaker assemblies to the V-1101A PG Place a check by each step as
ملخص المحتوى في الصفحة رقم 9
PUNCHDOWN BLOCK V-1101A TIP (W/BL) 26 T (W/BL) RING (BL/W) 1 R (BL/W) (W/O) 27 H (W/O) CONTACT (O/W) 2 DIR (W/G) MT (R/G) MR (G/R) ONE-WAY AMPLIFIED SPEAKER ASSEMBLIES PG (R/BR) OUT(BR/R) (V/BR) 49 AG (V/BR) A GROUND (BR/V) 24 AB(BR/V) A BATTERY (V/S) 50 BG (V/S) B GROUND (S/V) 25 BB (S/V) B BATT FIGURE 6 PAGE PORT ACCESS __ 10. Plug in the power supply. WIRING INSTRUCTIONS: __ 11. Test the system by dialing the telephone Place a check by each step as it is completed. system page access code or
ملخص المحتوى في الصفحة رقم 10
When connecting the V-1101A to a page port (Figure OPERATION 6) a Ground must be connected through the dry General contact closure of the telephone system page card to The V-1101A contains the required circuitry to allow both the Holding Ground and the Ground Start paging access from most types of telephone systems. terminals of the V-1101A. To operate correctly, the V-1101A must receive two Once the V-1101A has been activated it will remove signals: a ground on the Holding Ground input and the
ملخص المحتوى في الصفحة رقم 11
TROUBLESHOOTING CHART Symptom Solution 1. No output at speakers. 1. Check for audio on the Red/Brown pair of the V-1101A while paging. (a) If audio is present: Verify proper audio and power wiring to speakers. Try connecting a speaker in the equipment room: Connect the Tip and Ring leads directly to the Red/Brown pair of the V-1101A and connect the –24 Vdc and ground leads to the power supply. Test again. (b) If no audio: Refer to Wiring Instructions and complete the power test (step 7). Co
ملخص المحتوى في الصفحة رقم 12
VALCOM LIMITED WARRANTY Valcom, Inc. warrants its products to be free from defects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that: 1. inspection by Valcom, Inc. indicates the validity of the claim, 2. the defect is not the result of damage, misuse, or negligence