ملخص المحتوى في الصفحة رقم 1
APRIL 1999
PCA35A-R3
PCA35AE-R2
PS035A
PS034E
PQ-6 PLUS (RO)
®
Receive-only printer interface for IBM System 3X and AS/400
Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX
CUSTOMER
FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
SUPPORT
Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
INFORMATION
Web site: www.blackbox.com • E-mail: info@blackbox.com
PQ-6 Plus (RO)
START STOP
LF FF
TES
ملخص المحتوى في الصفحة رقم 2
PQ-6 PLUS (RO) FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules,
ملخص المحتوى في الصفحة رقم 3
PQ-6 PLUS (RO) INSTRUCCIONES DE SEGURIDAD (Normas Oficiales Mexicanas Electrical Safety Statement) 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato elé
ملخص المحتوى في الصفحة رقم 4
PQ-6 PLUS (RO) TRADEMARKS The trademarks mentioned in this manual are the sole property of their owners. 3
ملخص المحتوى في الصفحة رقم 5
PQ-6 PLUS (RO) CONTENTS 1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.1 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 6
PQ-6 PLUS (RO) 1. Specifications Controls—PCA35A-R3, PCA35AE-R2: Reset, Start, Stop, LF, FF, Test Speed—Serial port, 50 bps to 19.2 kbps Interface—IBM twinaxial; RS-232/V.24 DCE asynchronous or Centronics type parallel Connectors—(1) DB15 male with twinax V, (1) DB25 female Indicators—(5) LEDs: DTR, Line Sync, Power, Test, Data Out Temperature—Operating: 40 to 100 °F (5 to 42 °C); Storage: -40 to 140 °F (-40 to 60 °C) Humidity—0 to 95% noncondensing MTBF—50,000 hours Power—PCA35A-R2: 115-VAC, 6
ملخص المحتوى في الصفحة رقم 7
PQ-6 PLUS (RO) 2. Introduction 2.1 Application The PQ-6 PLUS (RO) is a “receive-only” microprocessor-based printer interface for the IBM System/34, System/36, and System/38 computers. It allows a printer with an RS-232 or Centronics compatible port to interface with IBM twinaxial cable via a male DB15 and twinax “pigtail” cable. Device address and serial or parallel output are switch selectable, and the baud rate is selectable in 16 settings from 50 to 19,200 bps. XON/XOFF and DTR are supported
ملخص المحتوى في الصفحة رقم 8
PQ-6 PLUS (RO) The Centronics parallel interface is a 25-pin, parallel byte interface. It has eight lines that carry their respective binary bits in parallel. The transmission of these data bits is controlled by the computer-supplied STROBE pulse. Handshaking (flow control) is achieved by asserting or deasserting either the ACKNLG or BUSY signal from the printer. Twinaxial PQ-6 PLUS (RO) Printer ASCII data serial Serial EBCDIC or parallel data and commands S/3X, AS/400 or remote controller (1 MH
ملخص المحتوى في الصفحة رقم 9
PQ-6 PLUS (RO) 3. Installation The installation procedure is divided into three sections: • Section 3.1, Initial Setup, explains how to position the PQ-6 (RO) after unpacking it, plug in the power supply, and run off-line tests. • Section 3.2, System Configuration and Connection, covers the considerations for setting up the PQ-6 PLUS (RO). Items covered include setting the device address and all corresponding physical connections. • Section 3.3, Placing the PQ-6 PLUS (RO) into Operation, details
ملخص المحتوى في الصفحة رقم 10
PQ-6 PLUS (RO) DB25 Female DB15 Male Reset Power Serial Parallel +5 Ground EPROM Power DTR Line Sync Test Data Out Figure 3-1. Board Layout. 9 SW1 SW2 ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
ملخص المحتوى في الصفحة رقم 11
PQ-6 PLUS (RO) Installing an RS-232 Printer Connect the 6-pin connector from the power supply to the 6-pin connector on the back of the PQ-6 PLUS (RO). Remove the top cover of the PQ-6 PLUS (RO). Do not plug it into the AC outlet at this time. Locate switch SW1 to set the baud rate and port configuration. Select the serial transmission speed (baud rate) for the PQ-6 PLUS (RO) output port using the four switches labeled Rate 4, Rate 3, Rate 2, and Rate 1 on the printed circuit board according to
ملخص المحتوى في الصفحة رقم 12
PQ-6 PLUS (RO) Installing a Centronics compatible printer Connect the 6-pin connector from the power supply to the 6-pin connector on the back of the PQ-6 PLUS (RO). Do not plug it into the AC outlet at this time. Place the large jumper strip at P3, in the “A-B” position for parallel output. The Centronics DB25 pinout is a standard DB25 to Centronics cable (Black Box part number EYN600) that connects the PC to the printer. This cable’s pinning is shown in Table 3-3. Table 3-3. Centronics to RS-2
ملخص المحتوى في الصفحة رقم 13
PQ-6 PLUS (RO) 3.1.3 OFF-LINE TEST OF PQ-6 PLUS (RO) AND PRINTER Initial Power On Test Once both the printer and the PQ-6 PLUS (RO) are plugged into the AC line, turn the printer power switch “ON” and put it into an “on-line” condition. Make sure the connection between the printer and the PQ-6 PLUS (RO) is complete. Run the following test to check the power and connections for both devices. Table 3-4. Initial Test. Initial Test Device Response Corrective Action Plug the PQ-6 (RO) PLUS Power and
ملخص المحتوى في الصفحة رقم 14
PQ-6 PLUS (RO) Self-Test After running the power test successfully, you can run the self-test to check the PQ-6 PLUS (RO) program memory (ROM) and buffer memory (RAM). You can perform the self-test via two different methods: internal DIP switches or the front-panel test button. Either way, the printer will print the software revision level, address selected, and printer emulated. The self-test will also send a printed barber-pole test pattern to the printer. The amount of data in the barber pole
ملخص المحتوى في الصفحة رقم 15
PQ-6 PLUS (RO) PQ6.PLUS REV1.41 SOFTWARE RAM OK ROM OK DEVICE ADDRESS 0 Printer = 5256 .<(+|& !$*);^-/,%>? -:#@'="abcdefghi jklmnopqr -stuvwxyz {ABCDEFGHI }JKLMNOPQ <(+|& !$*);^-/,%>? -:#@'="abcdefghi jklmnopqr -stuvwxyz {ABCDEFGHI }JKLMNOPQ .<(+|& !$*);^-/ ,%>? -:#@'="abcdefghi jklmnopqr -stuvwxyz {ABCDEFGHI }JKLMNOPQ <(+|& !$*);^-/ ,%>? -:#@'="abcdefghi jklmnopqr -stuvwxyz {ABCDEFGHI }JKLMNOPQR <(+|& !$*);^-/ ,%>? -:#@'="abcdefghi jklmnopqr -stuvwxyz
ملخص المحتوى في الصفحة رقم 16
PQ-6 PLUS (RO) 3.2 System Configuration and Connection At this point, the PQ-6 PLUS (RO)’s serial or parallel port has been tested off-line and verified to be in working condition. However, before attaching to the host system, you must consider the overall system layout to establish the relative device positioning, port selection, cabling, device addressing, and unit identification. 3.2.1 PQ-6 PLUS (RO) ADDRESS SELECTION Determine the correct device address number for the PQ-6 to use by contacti
ملخص المحتوى في الصفحة رقم 17
PQ-6 PLUS (RO) You must configure the system at a console to inform the operating system of the new device port, address, and unit ID assignments. NOTE You don’t have to configure the system if a previously existing 5256, 5224, or 5225 printer was replaced by the PQ-6 PLUS (RO) or if you have auto-config enabled on the AS/400. If the PQ-6 PLUS (RO) is replacing an existing device, printer ID and device addressing must remain as established for the removed device. 3.2.3 PRINTER CODES FOR PITCH AN
ملخص المحتوى في الصفحة رقم 18
PQ-6 PLUS (RO) No indicator lights Power supply not plugged Plug power supply cord into a suitable receptacle. into AC or into PQ-6. Line Sync light “OFF” Printer improperly addressed. Set correct address on SW2-6, 7, and 8; press RESET. Check twinax connections. DTR Flashing Attached printer OFF, in error Turn on attached printer or check for proper configuration. condition, or switches and P2 jumper not in proper position. Head moving printing No ribbon. Install new ribbon. Defective ribbon.
ملخص المحتوى في الصفحة رقم 19
PQ-6 PLUS (RO) 4. Operation 4.1 Operator Controls and Indicators Use Figure 4-1 to locate the controls, indicators, and connectors described in this section. START STOP TEST LF FF TEST DATA DTR LINE PWR OUT SYNC Figure 4-1. Front-Panel Controls and Indicators. 4.1.1 FUNCTION SWITCHES • Test: Pressing this switch will cause the TEST light to blink and a test pattern to be printed. If the PQ-6 (RO) cannot detect the attached printer, the TEST light will blink repeatedly. You can clear this conditi
ملخص المحتوى في الصفحة رقم 20
PQ-6 PLUS (RO) 4.1.2 INDICATOR LIGHTS • Power: Indicates that AC power has been applied to the unit. • Line Sync: Indicates that the PQ-6 is responding to host polls. • DTR (Data Terminal Ready): This signal from the printer to the PQ-6 PLUS (RO) indicates that the printer is ready. This signal must be present for printing to proceed. You can enable flow control from the PQ-6 PLUS (RO) to the printer via XON/XOFF characters (Hex 11/Hex 13) or by dropping DTR when the printer is not able to accep