ملخص المحتوى في الصفحة رقم 1
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,RE-1 - LINEAR P/N: 217490 C - INK: BLACK - MATERIAL: 20 LB. MEAD BOND WITH 80 LB. WHITE COATED COVER - SIZE: 8.500” X 11.000” - SCALE: 1-1 - FOLDING: ALBUM-FOLD - BINDING: SADDLE-STITCH
RE-1
Residential Telephone
Entry System
With Built-in Wireless Receiver
Installation,
Programming,
and Operation Instructions
(760) 438-7000
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
ملخص المحتوى في الصفحة رقم 2
CONTENTS FEATURES � TWO-WAY SPEAKERPHONE PRODUCT DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . .1 � CALL WAITING INSTALLATION INFORMATION . . . . . . . . . . . . . . . . . . . . 2 � CALL FORWARDING COMPONENT LOCATIONS . . . . . . . . . . . . . . . . . . . . . . . . 3 � DISTINCTIVE RINGS FOR ACCESS CALLS � SEVEN ACCESS TIME ZONES WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 � TIMED “DO NOT DISTURB” PRIVACY FEATURE ENTRY SYSTEM MOUNTING . . . . . . .
ملخص المحتوى في الصفحة رقم 3
System Features PRODUCT DESCRIPTION Time Zones Linear’s RE-1 Telephone Entry System is designed for residential The RE-1 contains an internal clock and calendar. Seven or light commercial access control applications. The speakerphone, programmable “time zones” allow setting time periods to schedule keypad, radio receiver, and optional video camera are housed in system functions. Each time zone can be active or inactive on certain a rugged enclosure that can be mounted to a pedestal or bolt
ملخص المحتوى في الصفحة رقم 4
Telephone Wires INSTALLATION INFORMATION The quality of the system’s audio communications is related to the Before beginning installation, please review the entire instructions type of telephone wire and its installation. Noise and hum can be and become familiar with the system’s operation, wiring, and introduced into the telephone wires. Use only high-quality telephone programmable options. wire rated for direct underground burial. All telephone wire should System Location be twisted-pair
ملخص المحتوى في الصفحة رقم 5
13 14 3 12 15 11 4 2 CALL 5 16 10 1 6 17 7 9 18 19 21 8 20 12 RELAY TERMINAL BLOCK COMPONENT LOCATIONS For Relay #1 and Relay #2 output connections to the access control 1 KEYPAD devices. Die-cast metal 12-key keypad with tactile action. For system 13 RELAY INDICATORS programming and keying in entry codes. Indicators for Relay #1 and Relay #2 will light when the relay is 2 DOWNLIGHT activated. Illuminates keypad and visitor operation buttons. The light can be 14 ANTENNA TERMINAL BLOCK progra
ملخص المحتوى في الصفحة رقم 6
N.C. N.C. COM EARTH COM EARTH N.O. N.O. TIP TIP N.C. N.C. RING RING COM TIP COM TIP N.O. RING N.O. RING WIRING DIAGRAM RELAY RATING: RELAY RELAY TYPICAL #1 #2 3 AMPS AT GATE INSTALLATION 30 VOLTS AC OR DC WIRING MAXIMUM RE-1 TELEPHONE ENTRY GATE OPEN SYSTEM OPERATOR 16 VAC TRANSFORMER 20 VA TRANSFORMER TRANSFORMER BATTERY NEGATIVE BATTERY POSITIVE SENSE #1 OPEN #1 CASE SENSE #2 GROUND OPEN #2 COMMON RING TO HOUSE HOUSE PHONES TIP KEYPAD CLK RING KEYPAD DVAL RE-1 TELEPHONE HOUSE KEYPAD DAT 0 TIP
ملخص المحتوى في الصفحة رقم 7
ENTRY SYSTEM MOUNTING TELEPHONE WIRING The RE-1 connects between the incoming telephone line of the Pedestal Mounting residence and local telephone sets. The RE-1 Entry System can be mounted on a standard pedestal. 1. Open the RE-1 case by removing the two security screws with the Telephone Bypass Module wrench provided (see Figure 2). The RE-1’s Telephone Bypass Module provides surge protection and 2. Use four security bolts and locking nuts to secure the backplate to the a switch to remove
ملخص المحتوى في الصفحة رقم 8
EARTH EARTH TIP TIP RING RING TIP TIP RING RING TELEPHONE WIRING OPTIONS Intercom Mode Shared Line Pressing the Call button on the RE-1 will cause the RE-1 to generate This is the standard confi guration. The telephone line is routed a ring signal as if it were an intercom station. A live phone line is not through the RE-1 to the house phones. Pressing the Call button on used and the RE-1 provides power for the remote intercom phone. the RE-1 will cause the RE-1 to disconnect the house phone
ملخص المحتوى في الصفحة رقم 9
EARTH EARTH TIP TIP RING RING TIP TIP RING RING EARTH EARTH TIP TIP RING RING TIP TIP RING RING EARTH EARTH TIP TIP RING RING TIP TIP RING RING EARTH EARTH TIP TIP RING RING TIP TIP RING RING MULTIPLE UNIT INSTALLATIONS Command Prefi x for Multiple Units Any of the four basic operation modes (Shared Line, Dedicated Line, Programming and relay control may be through the individual RE-1 Intercom, and Ring Down) may be used with multiple RE-1s in the keypads or through the house telephone(s) when
ملخص المحتوى في الصفحة رقم 10
N.C. COM N.O. N.C. COM N.O. N.C. COM N.O. N.C. COM N.O. Door or Pedestrian Gate Control CONTROL WIRING 1. Install a low voltage electric door strike or magnetic lock as a locking Gate Control device for the door or pedestrian gate. 1. Route two wires between the gate and the RE-1. Connect the gate 2. Install the power supply or transformer for the locking device. DO NOT operator’s OPEN terminals to the RE-1 Relay #1 COM & N.O. POWER THE RE-1 FROM THIS POWER SUPPLY. terminals. 3. Connect one
ملخص المحتوى في الصفحة رقم 11
EARTH TIP RING TIP RING POWER, BATTERY, & GROUND WIRING OPTIONAL REMOTE KEYPAD The optional Model AM-KP remote keypad can be used with the Power Wiring RE-1 entry system. A typical application for the remote keypad ✦ NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS would be to control a second door or gate. Entry codes are the only COMPLETE. method of access allowed at a remote keypad. The default system 1. Route two wires between the RE-1 and the power transformer. setting will cause th
ملخص المحتوى في الصفحة رقم 12
OPTIONAL KEYSWITCH A keyswitch can be installed in the RE-1 Entry System to provide keyed access. The RE-1 case is designed to accept the following keyswitch: KNOX COMPANY MODEL 3501 KNOX COMPANY 800-552-5669 www.knoxbox.com Keyswitch Installation 1. Disconnect the wiring harness connector and remove the antenna terminal block. Remove the four circuit board retaining screws and the INSTALL COVER PLATE RE-1 circuit board (see Figure 18). AND SPACER WITH FOUR SCREWS, LOCKNUTS, & NUTS 2. Remove
ملخص المحتوى في الصفحة رقم 13
OPTIONAL CCTV CAMERA Linear’s Model RE-BWC1 (P/N ACP00886A) CCTV camera can be installed inside the RE-1 Entry System. The camera provides a video signal for viewing the area in front of the entry system. The camera is continuously powered by the RE-1. The camera’s infrared light emitters illuminate the area directly on front of the entry system for nighttime or low light operation. The RE -1 CAMERA jack is used to connect the camera to the main circuit board with the double-ended modular c
ملخص المحتوى في الصفحة رقم 14
3. Double-click on “Local RE-1”. (The Local RE-1 icon can be dragged PROGRAMMING ACCESS to the desktop for easy future access). The RE-1 can be programmed locally or remotely. The system’s 4. Enter the RE-1’s programming master password (123456, unless built-in programming software can be accessed on-site or off-site changed) into the “Password” area. Select “Save Password” if you using a computer with any Internet browser. want the computer to retain the password. Without a computer, the
ملخص المحتوى في الصفحة رقم 15
SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION 1. FROM CONTROL PANEL SELECT "NETWORK 2. THE NEW CONNECTION WIZARD WILL START 3. NEW CONNECTION WIZARD - "NETWORK CONNECTION CONNECTIONS" THEN SELECT "NEW CONNECTION CLICK "NEXT" TYPE" SELECT "CONNECT TO THE INTERNET" OPTION WIZARD" 6. NEW CONNECTION WIZARD - "CONNECTION NAME" ENTER "RE-1 LOCAL" FOR A LOCAL CONNECTION 4. NEW CONNECTION WIZARD - "GETTING READY" 5. NEW CONNECTION WIZARD - "INTERNET CONNECTION" OR "RE-1 REMOTE" FOR A REMOTE CONNEC
ملخص المحتوى في الصفحة رقم 16
CONNECTING TO THE RE-1 WITH WINDOWS XP™ 1. DOUBLE-CLICK ON DESKTOP ICON TO LAUNCH THE CONNECTION WINDOW 2. CLICK "DIAL" TO START THE CONNECTION 3. THE MODEM WILL DIAL THE NUMBER 4. ONLY WHEN CONNECTING REMOTELY, AFTER THREE RINGS, CLICK "CANCEL", WAIT 10 SECONDS THEN REPEAT STEPS 1-3. THE RE-1 WILL ANSWER THE PHONE ON THE SECOND CALL ATTEMPT 5. THE RE-1 WILL VERIFY THE USERNAME AND PASSWORD 6. AFTER CONNECTING, SWITCH TO YOUR MICROSOFT INTERNET EXPLORER BROWSER SOFTWARE AND ENTER THIS ADDRESS:
ملخص المحتوى في الصفحة رقم 17
SETTING UP A WINDOWS VISTA™ DIAL-UP NETWORK CONNECTION (PART 1) 1. FROM THE START MENU, CLICK ON "CONNECT TO" 2. CLICK ON "SETUP A CONNECTION OR NETWORK" 3. CHOOSE "SET UP A DIAL-UP CONNECTION" 4. CLICK ON THE MODEM TO BE USED FOR THE CONNECTION 5. FILL IN THE INFORMATION FOR THE CONNECTION 6. CLICK ON "SET UP THE CONNECTION ANYWAY" 15
ملخص المحتوى في الصفحة رقم 18
SETTING UP A WINDOWS VISTA™ DIAL-UP NETWORK CONNECTION (PART 2) 7. CLICK ON "CLOSE" 8. FROM THE START MENU, CLICK ON "CONNECT TO" AND SELECT "RE-1" 9. IN THE CONNECT WINDOW, SELECT "PROPERTIES" 10. CLICK ON "CONFIGURE" AND UN-CHECK ALL HARDWARE FEATURES 11. CLICK ON "OK" THEN CLICK ON "NETWORKING" 12. CLICK ON "USE THE FOLLOWING IP ADDRESS" 13. CLICK ON "ADVANCED" AND UN-CHECK TAB. HIGHLIGHT "INTERNET PROTOCOL VERSION 4 AND ENTER 192.168.20.11 "USE IP HEADER COMPRESSION" (TCP/IPv4)" AND CLICK O
ملخص المحتوى في الصفحة رقم 19
CONNECTING TO THE RE-1 WITH WINDOWS VISTA™ 1. CLICK ON "DIAL" START THE CONNECTION 2. THE MODEM WILL DIAL THE NUMBER 3. ONLY WHEN CONNECTING REMOTELY, AFTER THREE RINGS, CLICK "CANCEL", WAIT 10 SECONDS THEN REPEAT STEPS 1-3. THE RE-1 WILL ANSWER THE PHONE ON THE SECOND CALL ATTEMPT 4. THE RE-1 WILL VERIFY THE USERNAME AND PASSWORD 5. AFTER CONNECTING, SWITCH TO YOUR MICROSOFT INTERNET EXPLORER BROWSER SOFTWARE AND ENTER THIS ADDRESS: http://192.168.20.10/re1.html 17
ملخص المحتوى في الصفحة رقم 20
LOCAL PROGRAMMING ACCESS REMOTE PROGRAMMING ACCESS Programming with a Local Telephone or the Unit’s Keypad Remote Programming with a Telephone Start with Step 1 below for local programming with the unit’s keypad For remote programming, the RE-1 can be called from any or a local telephone. TouchTone® telephone. Once the connection is made, the programming keystrokes are identical to what would be entered at 1. Enter “###” (unless the programming prefi x has been changed) then the Master Progra