ملخص المحتوى في الصفحة رقم 1
You can rely on
User’ Guide and Performa 30 HE
Important Warranty Information
Condensing
Combination Boiler
These instructions include the Benchmark Commissioning
Checklist and should be left with the user for safe keeping.
© Baxi Heating UK Ltd 2009
ملخص المحتوى في الصفحة رقم 2
Contents Section Page Natural Gas 1.0 Quick Reference Guide 3 Potterton Performa 30 HE o G.C.N 47 393 13 2.0 Troubleshooting 4 3.0 Fault Indication 6 4.0 System Pressure & Temperature 7 5.0 Clearances 8 6.0 Care of the Boiler 9 7.0 Legislation 10 8.0 Emergency 11 Where fitted, user label for 9.0 Warranty & Service 12 optional timer to be applied here The Benchmark Scheme Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and comm
ملخص المحتوى في الصفحة رقم 3
1.0 Quick Reference Guide 2 Reset 1 3 0 4 bar ON/OFF/Reset Indicator Central Heating Domestic Hot Water System Pressure Gauge Position of Selector Switch Neons Temperature Control Temperature Control Optional Timer Reset Reset Reset Reset OFF Position Central Heating & Hot Water Domestic Hot Water Reset The boiler will not operate. Both Heating & Hot Water will operate. Hot Water will operate. Hold for approx 5 seconds and release. Power On Indicator - The indicator will illuminate when there is
ملخص المحتوى في الصفحة رقم 4
Boiler not working 2.0 Troubleshooting START Make sure the gas supply is Is the ( ) light on and the YES YES NO Is the ON/OFF/Reset turned ON and check if other ( ) on ? Select Switch in the gas appliances are operating ( ) position and (e.g. fire, cooker). 30° 40° 50° 60° 70° 80° the Power ON indicator lit ? NO If no gas, consult your 30° 40° 50° 60° 70° 80° supplier. Reset Boiler On Burner On Indicator Indicator YES NO Power On Indicator Boiler operating satisfactorily. C
ملخص المحتوى في الصفحة رقم 5
5 4 3 2 25 25 1 20 20 2.0 Troubleshooting Is the Timer ON and calling for Is the Room Thermostat (if YES YES heat ? fitted) set high enough ? 12 15 Typical examples of external timer CH OFF CH ON NO Turn Room Thermostat to maximum setting (typical example shown). NO Ensure timer is set for Central 15 Heating ON (see any instructions supplied with timer). CONTACT YOUR INSTALLER OR SERVICE ENGINEER. If you don’t know what you need to do to get the boiler to light, or need help with the system and
ملخص المحتوى في الصفحة رقم 6
3.0 Fault Indication 3.1 Air Flow Monitor 1. The boiler is fitted with an air pressure sensing device. This NOTE: The neons annotated have a dual function, indicating the temperature of the monitors the flue system. central heating water when constantly illuminated or begin to flash to indicate a fault. 2. If the ( ) neon illuminates it indicates that the flue or Pump/Low Air Flow flue terminal is blocked or obstructed in some way, or that Pressure Neon Monitor Neon there is an internal
ملخص المحتوى في الصفحة رقم 7
4.0 System Pressure & Temperature 2 4.1 Central Heating System Pressure 1 3 1. The normal operating water pressure is between 1 and 2.5 bar (Fig. 4). If the pressure exceeds 3 bar the safety pressure 0 4 valve will operate and a fault is indicated (Fig. 6). Contact your bar installer. Fig. 4 2. It may be necessary to repressurise the system occasionally Normal Pressure (Fig. 5). A filling device (the filling loop) will be fitted on the system. If you are unsure of its position, or cannot identif
ملخص المحتوى في الصفحة رقم 8
5.0 Clearances 20mm/5mm Min 5.1 For your Safety see *NOTE: 5mm Min 450mm 1. This appliance must have been installed in accordance with the manufacturer’s instructions and the regulations in force. 200mm Min 2. Any modification that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty. In GB this could also infringe the Gas Safety (Installation and Use) Regulations. GB - Heating Indus
ملخص المحتوى في الصفحة رقم 9
6.0 Care of the Boiler 6.1 Cleaning the Outer case The painted panels should be wiped with a damp cloth and then dried completely. DO NOT USE ABRASIVE CLEANING AGENTS. 6.2 Protection & Precaution 1. The boiler incorporates an integral frost protection feature that will operate when the selector switch is in the ( ) position. If the boiler temperature falls below 5° C, then the boiler will operate until the water temperature has been raised. 2. If a system frost thermostat has been fit
ملخص المحتوى في الصفحة رقم 10
7.0 Legislation 7.1 Installation, Commissioning, Service & Repair 1. This appliance must be install in accordance with the manufacturer’s instructions and the regulations in force. Read the instructions fully before installing or using the appliance. 2. In GB, this must be carried out by a competent person as stated in the Gas Safety (Installation & Use) Regulations. 3. Definition of competence: A person who works for a Gas Safe registered company and holding current certificates in the relevant
ملخص المحتوى في الصفحة رقم 11
8.0 Emergency Warning ! If you smell gas Turn off the gas supply at the meter and call your gas supplier immediately. It is possible to isolate the boiler at the isolating valve (Fig. 10). In GB, Transco operate a 24 hour emergency service and the telephone number will be listed in your telephone directory. Faulty boiler If it is known or suspected that a fault exists on the boiler, it must not be used until the fault has been corrected by a competent person. In an Emergency If a water or gas
ملخص المحتوى في الصفحة رقم 12
Please complete the boxes below 9.0 Warranty & Service Serial Number Standard Warranty Term & Conditions 12 Months Free Warranty - register today To receive your 12 months free warranty please complete the form supplied with the boiler or simply call heateam, the service of Baxi Heating UK Ltd on 0800 731 1644. Our promise to you If you experience a fault with your new boiler, we aim to provide a safe and high quality repair service supported by our dedicated national network of Date of Install