ملخص المحتوى في الصفحة رقم 1
1000BASE-LX Gigabit Uplink Module
EM4582-LX-SC
Quick Installation Guide
ملخص المحتوى في الصفحة رقم 2
ملخص المحتوى في الصفحة رقم 3
Quick Installation Guide EM4582-LX-SC Gigabit Uplink Module Slide-in module with 1 1000BASE-LX (SC-type) port
ملخص المحتوى في الصفحة رقم 4
Copyright © 2000 by Accton Technology Corporation. All rights reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation. Accton makes no warranties with respect to this documentation and disclaims any implied warranties of mer- chantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice. Accton reserves the right to make
ملخص المحتوى في الصفحة رقم 5
Contents Description of Hardware 1 Gigabit Uplink Module 1 Gigabit Port LEDs 1 Installing the Module 2 Package Contents 2 Handling the Module 2 Instructions 2 Maximum Cable Lengths 5 Troubleshooting 6 Product Specifications 6 EMI Certification 7 FCC Class A Certification (USA) 7 Canada Department of Communications - Class A 7 BSMI Class A (Taiwan) 7 VCCI Class A Compliance (Japan) 7 CE Mark Declaration of Conformance for EMI and Safety (EEC) 8 Safety Compliance 8 Warning: Fiber Optic Port Safety
ملخص المحتوى في الصفحة رقم 6
Contents ii
ملخص المحتوى في الصفحة رقم 7
Description of Hardware Gigabit Uplink Module The EM4582-LX-SC fiber optic module is designed for use in Accton switch models which have a single-port Gigabit Ethernet transceiver slot. At present, suitable units include these CheetahSwitch Workgroup models – ES3514F, ES3526F, ES3526G, and ES3552. Detailed information about configuring these modules and advice about Fast Ethernet configuration rules can be found in the switch’s user guide. Warning: Before installing or removing the EM4582-LX
ملخص المحتوى في الصفحة رقم 8
User Guide Installing the Module Caution: Do not install this module in any unit other than the ES3514F, ES3526F, ES3526G, or ES3552. Contact your distributor for advice on newly released switches which may be designed for use with these modules. The EM4582-LX-SC fiber optic module is field installable. Just follow the instructions below. Package Contents This package includes: One EM4582-LX-SC fiber optic module This User Guide Owner registration card Handling the Module Caution: The E
ملخص المحتوى في الصفحة رقم 9
Installing the Module Keep the original faceplate for future use. If you should remove the module, replace the faceplate to prevent dust and debris from entering the unit and to maintain proper air flow. 5. Insert the new module into the switch: Holding the new module with the text on the front panel upright, carefully slide the module into a lower slot on the rear panel, and press gently until it snaps into place. Be sure the new module’s front panel is flush with the switch panel. Note: M
ملخص المحتوى في الصفحة رقم 10
User Guide 6. Secure the new module: Secure the new module in place by screwing the attached screws clockwise into the switch’s chassis. Tighten them enough to secure the module, but not so tight as to prevent them from being unscrewed by hand. 7. Connect the network cable to the module: Connect fiber cable to the port on the newly installed module. See “Maximum Cable Length” on page 5 in this guide for further information. 8. Power on the switch: Reconnect the previously removed power so
ملخص المحتوى في الصفحة رقم 11
Maximum Cable Lengths Maximum Cable Lengths Cable Types and Specifications Connector Cable Type Max. Length RJ-45 10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45 100BASE-TX Cat. 5 100-ohm UTP 100 m (328 ft) 100BASE-FX 50/125 or 62.5/125 micron core multimode fiber SC or ST Half duplex 412 m (1,351 ft.) SC or ST Full duplex 2 km (1.24 miles) 1000BASE-SX 50/125 or 62.5/125 micron core See the SC or ST multimode fiber 1000BASE-SX table 1000BASE-LX 50/125 or 62.5/125 micron core MMF See the
ملخص المحتوى في الصفحة رقم 12
User Guide Troubleshooting If you experience any problems with the module, check the following items before contacting Accton Technical Support: Ensure the switch with the fiber optic module is powered up. Ensure that the device attached to the module is powered up and operating correctly. Ensure that the module is properly seated in the slot. Verify that the module port is configured to match the communication mode used by the attached device (full or half duplex). Check the connec
ملخص المحتوى في الصفحة رقم 13
EMI Certification EMI Certification FCC Class A Certification (USA) Warning: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in
ملخص المحتوى في الصفحة رقم 14
User Guide CE Mark Declaration of Conformance for EMI and Safety (EEC) This is to certify that this product complies with ISO/IEC Guide 22 and EN45014. It conforms to the following specifications: EMC: EN55022(1988)/CISPR-22(1985) class A EN60555-2(1995) class A EN60555-3 IEC1000-4-2(1995) 4kV CD, 8kV AD IEC1000-4-3(1995) 3V/m IEC1000-4-4(1995) 1kV - (power line), 0.5kV - (signal line) IEC1000-4-6(1995) 3Vrms This product complies with the requirements of the Low Voltage Directive 73/23/EEC
ملخص المحتوى في الصفحة رقم 15
Safety Compliance Underwriters Laboratories Inc. (USA) Important! Before making connections, make sure you have the correct Cord Set. Check it (read the label on the cable) against the following specification list. Operating Voltage Cord Set Specifications 120 Volts UL Listed/CSA Certified Cord Set Minimum 18 AWG Type SVT or SJT three conductor cord Maximum length of 15 feet Parallel blade, grounding type attachment plug rated 15A, 125V 240 Volts (Europe only) Cord Set with H05VV-F cord having
ملخص المحتوى في الصفحة رقم 16
User Guide Warranty Accton warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for a period of three (3) years from the date of purchase from Accton or it’s Authorized reseller. For the warranty to apply, you must register your purchase by returning the registration card indicating the date of purchase and including proof of purchase. There will be a minimal charge to replace consumable components, such as fuses, po
ملخص المحتوى في الصفحة رقم 17
ملخص المحتوى في الصفحة رقم 18
EM4582-LX-SC E102000-R01 150514-102